Technical FAQ topic
How to Review Cavitation and Available NPSH
Review vapour pressure, liquid level, suction piping and the duty point to assess cavitation risk.
01What is available NPSH (NPSHa)?
Conclusion
NPSHa is the cavitation margin available from the plant suction conditions, calculated from level, pressure, temperature, vapour pressure and losses.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Confirm liquid level and pressure taps
- Calculate vapour pressure at temperature
- Deduct suction-line losses
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
02What is required NPSH (NPSHr) for the pump?
Conclusion
NPSHr is the margin required by the pump at a defined speed, impeller, flow and test condition, taken from the relevant curve or manual.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Confirm speed and impeller
- Read NPSHr at the relevant flow
- Compare with NPSHa and design margin
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
03Why can higher temperature increase cavitation risk?
Conclusion
Higher temperature usually raises vapour pressure and reduces available NPSH; viscosity and density changes also affect the system calculation.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record the temperature range
- Obtain vapour pressure
- Recalculate NPSHa
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
04Which suction-line issues reduce NPSHa?
Conclusion
Small suction lines, excessive elbows, blocked filters, air leaks, low level and trapped air can increase losses or reduce effective suction conditions.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Check pipe size and elbows
- Check filter pressure drop
- Inspect for air leaks and trapped air
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
05Can the pump continue running when cavitation occurs?
Conclusion
Do not continue without confirming the cause and safe conditions. Follow the site procedure to reduce load or stop, then check level, valves, filter, temperature and duty.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Confirm it is safe to inspect
- Reduce load or stop
- Record instruments and duty data
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
06Which process changes require an NPSH review?
Conclusion
Review NPSH after changing the medium, raising temperature, lowering level, modifying suction piping, changing flow/speed or adding filter resistance.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- List conditions before and after
- Recalculate NPSHa
- Check the relevant curve and margin
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.