Technical FAQ topic
How to Define Flow, Head and System Pressure Together
Review flow, head, pressure and the system curve as one duty point.
01Why should a pump not be selected only by maximum flow?
Conclusion
Flow must be checked with head as one duty point on the performance curve, together with density, viscosity, system resistance, NPSH and motor power.
Why this matters
Comparing maximum flow alone can place the pump away from the intended duty region in the actual system.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Define normal, minimum and maximum flow
- Calculate static head and piping loss
- Check the flow/head combination on the curve
Applicable conditions
For preliminary centrifugal, magnetic-drive and chemical-process pump selection.
Limits and risks
A catalogue maximum is not a result available from every size under every duty.
02How are head and system pressure related?
Conclusion
Head expresses energy added by the pump, while system pressure describes the plant boundary and losses. They must be reconciled using density, static difference and piping resistance.
Why this matters
The same pressure difference represents a different head for different medium densities.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record inlet and outlet pressure
- Confirm density and temperature
- Calculate the duty from static difference and resistance
Applicable conditions
For systems that convert process pressure into pump head.
Limits and risks
Pump selection cannot be confirmed without pressure tap locations, density and piping conditions.
03Do pressure fluctuations affect selection?
Conclusion
Yes. Start-up, shutdown, valve changes and process variation can change the duty point, casing loads and containment boundary. Normal and transient ranges should be provided.
Why this matters
A steady-state pressure value can miss peak or vacuum conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record normal, minimum and maximum pressure
- Mark start/stop and valve-change transients
- Check casing, shell and piping pressure limits
Applicable conditions
For fluctuating-pressure and batch process systems.
Limits and risks
Transient analysis and plant safety-valve design must be completed by the responsible disciplines using the complete process data and project specifications; steady-state pressure records may miss peak or vacuum conditions.
04How is motor power determined from flow and head?
Conclusion
Power review also needs density, gravity, pump efficiency, duty point and margin. Flow or head alone is not enough.
Why this matters
Density and viscosity affect shaft power, so the motor must match the exact curve and configuration.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Define the duty point
- Confirm density and viscosity
- Check shaft power and motor configuration against the curve
Applicable conditions
For motor sizing during pump selection.
Limits and risks
Do not transfer a motor configuration from one size or medium to another.
05How should the system and pump curves be used together?
Conclusion
The system curve represents resistance at different flows; the pump curve represents capacity at a defined speed, impeller and medium condition. Their intersection is the duty point to review.
Why this matters
Valves, pipe size, liquid level and medium properties can change either curve.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Build the system resistance curve
- Select the curve for the speed and impeller
- Check intersection, NPSH, efficiency and power
Applicable conditions
For centrifugal and process pump selection.
Limits and risks
A curve from a similar model or different revision is not a substitute for the relevant curve.
06When should the duty point be reviewed again?
Conclusion
Recheck flow, head, pressure, NPSH and power when density or viscosity, temperature, piping, valves, level, speed or target capacity changes.
Why this matters
The duty point is the joint state of the pump and system under current conditions, not a permanent model label.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record conditions before and after the change
- Recalculate system resistance
- Review the curve and protection settings
Applicable conditions
For modifications, medium changes, expansion and variable-speed operation.
Limits and risks
The original order model alone does not confirm suitability after a modification.