Technical FAQ topic
How to Assess Medium and Pump Material Compatibility
A structured review path from medium composition, concentration and temperature to wetted materials.
01What should be reviewed first for medium compatibility?
Conclusion
Confirm the medium's composition, concentration, temperature, density, viscosity and any mixing or crystallization changes, then review the casing, lining, bearings, seals and containment shell separately.
Why this matters
One medium name can represent different concentrations, temperatures or contaminants, so material selection must retain those variables.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record the complete composition
- Provide normal, minimum and maximum temperatures
- List each wetted or supporting component for review
Applicable conditions
For corrosive, volatile or composition-sensitive process media.
Limits and risks
A name match is not a compatibility conclusion without material data, samples or technical review.
02Can a pump be selected from the medium name alone?
Conclusion
No. The medium name is only a starting point. Composition, concentration, temperature, density and viscosity are normally required, with solids, crystallization and mixture changes where relevant.
Why this matters
These inputs affect compatibility, hydraulics, power and cavitation review.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Confirm composition rather than a trade name
- Add concentration, temperature and properties
- Include operating ranges in the enquiry
Applicable conditions
For chemical-process, corrosion-resistant and non-metal pump selection.
Limits and risks
Incomplete data supports only a candidate range, not final model or material confirmation.
03Should casing, lining and containment shell be checked separately?
Conclusion
Yes. Casing, lining, bearings, seals and containment shells see different contact, pressure, temperature and friction conditions. One generic pump-material label is not enough.
Why this matters
The material combination depends on the model and configuration; one component description cannot be extended to the whole pump.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- List wetted components
- Mark temperature, pressure and friction conditions
- Review each item against the manual material table
Applicable conditions
For metal, non-metal and fluoroplastic pumps.
Limits and risks
Do not publish a definitive grade until the order configuration and material documents are confirmed.
04Does a change in concentration change material selection?
Conclusion
It can. Concentration changes may alter corrosion, viscosity, density, crystallization and temperature limits, so normal, minimum and maximum concentration should be reviewed separately.
Why this matters
A single typical concentration can miss harsher conditions during mixing, start-up or shutdown.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- List the concentration range and mixing method
- Mark dilution or blending stages
- Review materials and hydraulics for each stage
Applicable conditions
For acids, alkalis, salts and mixed media with changing concentration.
Limits and risks
Do not use one concentration or an unconditional statement to infer all duties.
05Why must temperature and pressure be considered together?
Conclusion
Temperature affects materials, viscosity, vapour pressure and containment boundaries, while pressure affects casing, shell and piping loads. Both must be reviewed with flow, head and configuration.
Why this matters
Manual temperature or pressure ranges normally carry model, material and duty conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record normal and peak temperature
- Record inlet, outlet and system pressure
- Check the exact model's material and pressure boundaries
Applicable conditions
For hot, cold, volatile or pressure-variable media.
Limits and risks
A short-duration material temperature or pressure value is not a long-term whole-pump allowance.
06When is a sample or dedicated compatibility review needed?
Conclusion
Use a sample, material data or a dedicated review when the medium is complex, concentration or temperature varies widely, solids or crystallization are present, or the material table does not cover the duty.
Why this matters
Sample testing supplements a material table but does not replace pressure, cavitation, installation or safety review.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Prepare sample and analysis data
- Define wetted materials and test temperature
- Record test duration, appearance and observations
Applicable conditions
For new, mixed or high-uncertainty media.
Limits and risks
A sample result does not automatically represent every batch, concentration or long-term duty.