Technical FAQ topic
What Data Is Needed for Solids, Crystallizing or Fibrous Media
Describe solids and crystallization before reviewing impeller, bearing, passage and filtration choices.
01What data is needed when the medium contains solids?
Conclusion
Provide particle material, content basis, size distribution, maximum size, hardness, shape and settling behaviour.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Confirm mass or volume basis
- Record typical and maximum size
- State hardness and settling
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
02Why does particle hardness affect pump selection?
Conclusion
Hardness affects wear risk for the impeller, bearings, sleeves and passages, and changes filtration and maintenance needs.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Provide hardness or material
- Identify wetted and supporting parts
- Assess filtration and inspection intervals
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
03What matters when selecting for crystallizing media?
Conclusion
Review crystallization temperature, where crystals form after shutdown, heating/flushing, solids changes and restart conditions.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record crystallization temperature and time
- Mark shutdown and flushing steps
- Check passages, bearings and restart
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
04What risks do fibres or stringy contaminants create?
Conclusion
Fibres can wrap rotating parts, obstruct passages or affect filtration. Provide length, content, flexibility and tendency to entangle.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Record fibre length and content
- State entanglement tendency
- Review impeller and filtration
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
05Can a standard magnetic-drive pump be used directly for solids?
Conclusion
Not from the phrase 'a small amount of solids'. Review particle data, circulation paths, bearing materials and configuration; some models are unsuitable.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Obtain complete particle data
- Check the magnetic-drive internal design
- Have technical staff review the model
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.
06Why provide viscosity and settling for slurry duty?
Conclusion
Slurry viscosity, solids and settling affect start-up, passage capacity, power and post-shutdown cleaning.
Why this matters
The result depends on the interaction between the medium, pump design and system conditions.
Apply this conclusion only after the operating data and the exact pump configuration have been checked together.
Review steps
- Provide viscosity and solids range
- State settling and shutdown duration
- Review start-up and cleaning conditions
Applicable conditions
Use the exact model, configuration and actual duty data.
Limits and risks
A catalogue range or one test value does not confirm every size or duty.