TechnicalCenter

Technical Center

Technical FAQ topic

How to Select Metal Magnetic-drive Pumps by Duty and Design

Screen candidate models by duty, metallic wetted parts, shell, circulation arrangement and pump design.

01Should metal magnetic-drive pump selection start with a model or the duty?

Conclusion

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Complete the duty sheet
  2. Calculate or review the system duty point
  3. Shortlist models with matching curve and design evidence

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.

02Does a stainless-steel casing establish medium compatibility?

Conclusion

No. Confirm the exact alloy, concentration, temperature, contaminants and water content, plus the shell, bearings, gaskets and other wetted parts.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Confirm complete medium composition
  2. List every wetted component
  3. Check each item against the model material list

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.

03How are temperature and pressure reviewed for a metal magnetic-drive pump?

Conclusion

Review normal/peak temperature, inlet/outlet pressure and static system pressure with the material configuration. Every range endpoint must stay tied to a model, size and revision.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Record the temperature-pressure envelope
  2. Check casing and shell limits
  3. Confirm flanges, motor and protection

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.

04What mainly differs among metal magnetic-drive pump series?

Conclusion

They may differ in single/multistage, horizontal/vertical, self-priming/submerged arrangement, suction conditions, hydraulic range, circulation and shell configuration.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Define the process task
  2. Build a design comparison
  3. Exclude series that fail hard limits

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.

05Can a metal magnetic-drive pump be selected directly for solids or crystallizing media?

Conclusion

Not by family name alone. Review particle size, content, hardness, settling and crystallization together with circulation, bearings and passages.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Provide solids and crystallization data
  2. Review passages and circulation
  3. Confirm cleaning, flushing and shutdown

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.

06How is motor power determined for a metal magnetic-drive pump?

Conclusion

Calculate it from actual density, viscosity, duty point, efficiency, starting load and drive configuration; do not copy a clean-water or sample-duty motor.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Confirm properties and duty
  2. Review shaft power and margin rules
  3. Check supply, environment and starting method

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.

07Do all models have double shells or monitoring options?

Conclusion

No such assumption should be made. Layer count, material and monitoring interfaces are model/order options and require confirmation in drawings or order documents.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Confirm the target model
  2. Review drawing and configuration code
  3. Record monitoring in the technical agreement

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.

08Which documents are needed for a metal magnetic-drive pump enquiry?

Conclusion

In addition to the duty sheet, use the matching curve, material list and sectional/dimensional drawing. Hazardous media also require project safety and control requirements.

Why this matters

Metal magnetic-drive pumps span different hydraulics, alloy combinations, shells and circulation arrangements, so the family name is only an initial filter.

A design family narrows the candidates only. Final judgement still requires the exact model, material configuration, duty point and site system to be reviewed together.

Review steps

  1. Compile duty and medium data
  2. Confirm model and revision on every document
  3. Record deviations and open items

Applicable conditions

For selection where composition, temperature, flow, head, system pressure, NPSH and installation are known.

Limits and risks

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

Next step

Submit the full duty and candidate model, then review the matching curve, material list and sectional drawing.