MDZA and MDZE Magnetic-Drive Petrochemical Process Pumps
Product inquiry: 0523-84832479Product introduction
The MDZA is a single-stage, single-suction horizontal magnetic-drive petrochemical process pump with casing-foot support (OH1); the MDZE uses centerline casing support (OH2). Both use magnetic drive for a static seal.
Product presentation

- High-temperature service
- High mechanical strength
- Long service life
- Broad application range
Series characteristics do not replace selection for the specific medium, duty and individual configuration.
Structural design introduction
Single-stage, single-suction horizontal design; confirm the support arrangement and wetted-part configuration during selection.

Construction and features
The casing, support arrangement, materials and seal configuration are selected for the conveyed medium and operating conditions.
Main construction features
- 01 Selected materials: 304, 316L, Hastelloy C, titanium alloy and others; the material is selected for the conveyed medium.
- 02 Pump construction: single-stage, single-suction horizontal design; MDZA uses foot support OH1 and MDZE uses centerline support OH2.
- 03 Double isolation sleeve: the outer layer is made of non-metallic material, with low magnetic eddy-current loss and high efficiency. This is an optional construction and must be confirmed during selection.
Product information
| Product information | |
|---|---|
| Product name | MDZA and MDZE magnetic-drive petrochemical process pumps |
| Model | MDZA / MDZE |
| Brand | Jiangsu Wuxin Pump Industry Co., Ltd. |
| Dimensions | Customized to requirements |
| Origin | Jingjiang, Jiangsu |
Model identification (series example; final order specification is confirmed by selection)
MDZA(E)100-50-315A
- MDZA(E)
- Magnetic-drive petrochemical process pump series designation
- 100
- Suction size, mm
- -50
- Discharge size, mm
- -315
- Nominal impeller diameter, mm
- A
- Impeller trim code A, B, C, D, ...
Performance parameter ranges
| Performance parameter ranges | |
|---|---|
| Outlet size | DN25~DN400 mm |
| Speed | 1450/2900 r/min |
| Flow | 4~2400 m³/h |
| Head | 4.5~260 m |
| Pressure rating | 2.5~10 MPa |
| Power | 0.55~630 kW |
| Operating temperature | -100~350 °C |
These are series reference ranges and do not mean that an individual pump covers every limit at once. Confirm actual performance, materials and installation dimensions against the selected model and supplied technical documents.
Application range
Suitable for low- or high-flow, high-head and low-NPSH duties, as well as high- or low-temperature conditions. The pump can convey clean media that are prone to crystallization or solidification, flammable, explosive, easily vaporized, volatile, highly toxic, corrosive or valuable, and media containing a small amount of non-ferrous fine particles.
Suitable for chemical, pharmaceutical, petrochemical, papermaking, metal-smelting, food and wastewater-treatment industries. Confirm medium compatibility, particle conditions and operating limits during selection.
Working conditions
| Working conditions | |
|---|---|
| Speed | 1450/2900 r/min |
| Flow | 4~2400 m³/h |
| Head | 4.5~260 m |
| Pressure rating | 2.5~10 MPa |
| Operating temperature | -100~350 °C |
These are series ranges. An individual pump's permissible combination depends on the model, materials, medium and auxiliary systems and must be confirmed against selection and supplied technical documentation.

Structural design features
- Single-stage, single-suction, horizontal configuration.
- MDZA models use casing-foot support (OH1); MDZE models use centerline casing support (OH2).
- Floating impeller design: most axial thrust is balanced hydraulically, with the remainder carried by a flat thrust bearing.
- SKF bearings have a stated design service life of approximately 25,000 hours.
- The pump core uses a cartridge-style assembly comprising the inner magnetic rotor, isolation sleeve, pump cover, shaft, shaft sleeve, plain bearing and flat thrust bearing. The assembly provides high concentricity and smooth operation.
- A double isolation-sleeve arrangement is optional. Its outer sleeve uses a non-metallic material to reduce magnetic eddy-current loss and improve overall unit efficiency.
- An alarm device is provided. If the inner isolation sleeve fails, the outer sleeve can prevent the medium from escaping to atmosphere. Replacement of a canned-motor pump is possible when operating conditions permit.
- Multi-fin, oil-bath-lubricated bearing housing: helps improve heat dissipation and support longer bearing service life.
- Optional dry-run protection and overload-power protection devices are available; confirm the configuration during selection.
Selection and ordering inputs
MDZA and MDZE pumps are selected according to medium properties, installation conditions and required performance. Before ordering, provide the following operating parameters so that wetted-part materials, support configuration and accessories can be confirmed.
- Medium name and specific gravity;
- Presence, content, particle size and hardness of solids;
- Medium viscosity;
- Working environment and temperature;
- Medium composition and concentration;
- Required flow and head;
- NPSH available at the installation.
The pump structure can be reviewed for special operating conditions; installation dimensions are provided with the order drawings.
Operating boundaries
Installation, operation and maintenance should follow the product manual and supplied technical documentation. Confirm the following boundaries during selection and use:
- Do not run the pump dry. Fully close the discharge valve during start-up; continuous operation with the discharge valve closed must not exceed 1 minute. After start-up, slowly open the discharge valve and adjust to the required duty.
- Before start-up, confirm that the rotation direction matches the pump rotation mark; viewed from the motor fan end, rotation must be clockwise. Reverse rotation will damage the pump.
- If the inner and outer magnetic rotors are not properly coupled, stop the pump within 1 minute.
- Do not operate the pump with gas mixed into the medium.
- Frequent starts and stops reduce durability; do not exceed six start/stop cycles per hour.
- Maintain at least the minimum flow specified in the manual, which must not be less than 30% of the standard flow. Do not exceed the permitted maximum flow or the motor rated current.
- Discharge pressure must not exceed the pressure limit stated in the manual for the selected model. Pressure and flow limits must be confirmed against the performance test data sheet and supplied technical documentation.
- Liquid temperature during start-up, shutdown and operation, cooling or insulation requirements, and protection against hot surfaces must be confirmed for the specific model and supplied technical documentation.
Product information
| Model designation | MDZA and MDZE Magnetic-Drive Petrochemical Process Pumps |
|---|---|
| Catalog category | Metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.