MKLJ Magnetic-Drive Vertical Slurry Chemical Pump
Product inquiry: 0523-84832479Product introduction
The MKLJ magnetic-drive vertical slurry chemical pump uses a single-stage, single-suction vertical arrangement with steel-frame mounting. An open impeller is identified for duties above 10% solids content where heavy particles and abrasion are present; a closed impeller is identified below 10% solids.
An inert-gas seal keeps the sealing medium outside the rotor chamber and protects the rotor core. The casing, impeller, pump cover and auxiliary impeller can be cast in duplex stainless steel according to the medium. The shaft-sleeve-free and plain-bearing-free construction supports no-load operation, while cooling and insulation equipment can be configured for the duty.
The example MKLJ 80-50-250 A identifies each field of the model code. It does not establish that a particular inlet, outlet, impeller diameter and trimming sequence is performance-guaranteed.
Product presentation
MKLJ magnetic-drive vertical slurry chemical pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability labels summarize the series; suitability depends on the selected model and duty.
Structural overview
Single-stage, single-suction vertical construction with steel-frame mounting. An open impeller is identified above 10% solids content; a closed impeller is identified below 10% solids.
Confirm impeller type, wetted material, sealing and cooling or insulation against solids content, abrasiveness, temperature and operating method. The 10% threshold is an impeller-selection boundary, not a universal guarantee for every medium.
MKLJ vertical structural section

Structure and advantages
- Single-stage, single-suction vertical construction with steel-frame mounting.
- An open impeller is identified above 10% solids content; a closed impeller is identified below 10% solids.
- An inert-gas seal keeps the sealing medium outside the rotor chamber and protects the rotor core.
- The casing, impeller, pump cover and auxiliary impeller can be cast in duplex stainless steel according to the medium to improve abrasion and corrosion resistance.
- The non-metallic isolation sleeve reduces magnetic eddy-current loss.
- The shaft-sleeve-free and plain-bearing-free construction supports no-load operation and is described as adaptable to varied duties.
- Cooling and insulation equipment can be configured according to the application.
MODEL IDENTIFICATION
MKLJ8050250A
- MKLJ
- Magnetic-drive dry-run-capable vertical slurry chemical pump series.
- 80
- Pump inlet diameter in mm.
- 50
- Pump outlet diameter in mm.
- 250
- Nominal impeller diameter in mm.
- A
- Impeller trimming sequence; the series also includes B, C and D sequences.
Performance parameter ranges
Series coverage
| Parameter | |
|---|---|
| Inlet size | DN25~DN350 mm |
| Speed | 1450/2900 r/min |
| Flow | 1.5~1700 m³/h |
| Power | 0.55~560 kW |
| Head | 8~125 m |
| Pressure rating | 2.5 MPa |
These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.
Application range
For applications with environmental and safety requirements, conveying slurry with a high solids content, strongly abrasive media and high-melting-point media.
Confirm suitability against medium properties, solids content, particle shape and hardness, temperature, material compatibility and operating duty. The application description does not guarantee every medium or authorize substitution.
Selection and operating boundaries
Select the MKLJ according to medium, solids content, abrasiveness, temperature, installation conditions and required flow and head. Provide the complete duty so that the open or closed impeller, wetted materials, isolation sleeve, seal, cooling or insulation and motor can be confirmed.
- Medium name, composition, concentration and specific gravity;
- Solids content, particle size, shape and hardness;
- Medium viscosity, operating temperature and ambient temperature;
- Required flow, head, speed and pressure rating;
- Available NPSH, installation height and steel-frame conditions;
- Cooling, insulation, no-load operation and safety-protection requirements;
- Power supply, explosion protection and site environmental-safety boundaries.
The 10% impeller boundary, no-load operation claim and cooling or insulation arrangement must be confirmed for the selected model. The series model diagram does not replace duty calculations or medium-compatibility review.
Product information
| Model designation | MKLJ Magnetic-Drive Vertical Slurry Chemical Pump |
|---|---|
| Catalog category | Metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.