Product introduction

The MCQH magnetic-drive chemical process pump uses two single-suction impellers arranged back-to-back for low-flow, high-head duties formerly served by multistage or high-speed pumps. Confirm staging, performance and materials for the selected model.

Product presentation

MCQH magnetic-drive low-flow, high-head chemical process pump

MCQH magnetic-drive low-flow, high-head chemical process pump brand visual, showing the Jiangsu Wuxin Pump Industry Co., Ltd. name, thirty-years slogan, MCQH model lettering, WUXIN PUMP wordmark, complete two-stage pump train, coupling guard, motor, base and blue diagonal stage.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These capability labels summarize the series; suitability depends on the selected model and duty.

Structural overview

Two-stage, single-suction, horizontal design with centerline casing support (OH2).

MCQH two-stage pump structure and equipment

Complete MCQH magnetic-drive low-flow, high-head chemical process pump assembly, showing the two-stage casing, suction flange, centerline support, coupling, yellow guard, green motor and mounting base.

Structural details

The main construction features are summarized below; confirm the final arrangement for the selected model.

Quick structural highlights

  • 01 Selected material: Hastelloy and titanium alloys, according to the medium.
  • 02 Compact construction: low-specific-speed two-stage impellers for stable, reliable operation and long service life.
  • 03 Standards: API 685 first edition, SH/T 3148-2007 and ISO 2858. These concern seal-less-pump requirements, petrochemical centrifugal-pump engineering and dimensional practice respectively; they are not merged into a single certification claim.

Product information

MCQH product information
Product nameMCQH magnetic-drive low-flow, high-head chemical process pump
ModelMCQH
BrandJiangsu Wuxin Pump Industry Co., Ltd.
DimensionsCustomized to requirements
OriginJingjiang, Jiangsu

Confirm the final configuration against the selected model documentation.

Model identification (series example; final order specification is confirmed by selection)

MCQH-65-40-315×2A

MCQH
Magnetic-drive low-flow, high-head chemical process pump series designation
-65
Suction size, mm
-40
Discharge size, mm
-315×2
Nominal impeller diameter, mm
A
Impeller trim code A, B, C or D

Performance parameter ranges

MCQH series ranges
Outlet sizeDN20~DN100 mm
Flow1.3~120 m³/h
Head60~400 m
Pressure rating2.5~5 MPa
Speed2900 r/min
Power5.5~630 kW
Operating temperature-45~350 °C

These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.

Application range

For low-flow, high-head duties in petrochemical, coal-chemical, pharmaceutical, pesticide, metallurgical, papermaking, environmental-protection and electronics industries, including services using multistage or high-speed pumps.

Suitable media include flammable, explosive, volatile, toxic and corrosive media. Confirm compatibility, temperature, viscosity and solids for the actual duty.

Referenced standards

The following standards apply to this series. Their names and numbers are listed separately; this does not imply certification or that every standard covers every model.

  • API 685, first edition: Sealless Centrifugal Pumps for Petroleum, Heavy Chemical, and Natural Gas Industry Applications.
  • SH/T 3148-2007.
  • ISO 2858.

Confirm applicable editions, clauses and actual conformity in the contract, technical agreement and final product documentation.

MCQH working equipment and arrangement

Complete MCQH magnetic-drive chemical process pump in a working-condition view, showing the two-stage casing, upper flange, centerline support, coupling, yellow guard, green motor and base against a light floor and blue background.

Structural design features

  • Two low-specific-speed open impellers are arranged back-to-back and axially symmetrically; each stage is single-suction.
  • An integrated internal passage directs first-stage discharge to the second-stage inlet, avoiding an external crossover section and reducing component count.
  • An interstage leakage-control device between the opposed impellers balances residual axial thrust during operation.
  • An overload-power protection arrangement within the specified flow and head range keeps the magnetic-drive components floating during operation.
  • SKF bearings have a design life of approximately 25,000 hours; a multi-fin oil-bath bearing housing helps improve heat dissipation.
  • Interfaces are reserved for temperature and liquid-leakage probes and an alarm; a monitoring and protection system can be configured.

Pump wetted-part materials

Materials and temperature limits
01 Wetted partsCasing, impeller, cover, shaft sleeve, shaft and inner-magnet support are selected from stainless steel or alloy materials according to the medium.
02 Isolation sleeveTitanium alloy or C276.
03 Bearings, shaft sleeve, wear ring, anti-return ring and thrust bearingTungsten-carbide WT, or pressureless-sintered silicon-carbide SSC.
04 Magnetic materialSamarium-cobalt Sm2Co17, maximum temperature 350 °C; neodymium-iron-boron NdFe2Fe14B, maximum temperature 120 °C.

A listed material code does not establish compatibility with a specific medium. The maximum magnetic-material temperatures are material limits, not permission to operate the selected pump at those temperatures without further qualification.

Product information

Model designationMCQH Magnetic-Drive Low-Flow, High-Head Chemical Process Pump
Catalog categoryMetal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Should metal magnetic-drive pump selection start with a model or the duty?

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.