MCHD Magnetic-Drive Multifunctional Low-Flow, High-Head Chemical Process Pump
Product inquiry: 0523-84832479Product introduction
The MCHD magnetic-drive multifunctional chemical process pump combines self-priming, gas-liquid entrainment, low-level lifting and high-pressure transfer for low-flow, high-head duties. Confirm performance, materials and protection against the selected model.
Product presentation
MCHD magnetic-drive multifunctional low-flow, high-head chemical process pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability labels summarize the series; suitability depends on the selected model and duty.
Structural overview
Single-stage, single-suction, horizontal design with centerline casing support (OH2).
MCHD pump structure and equipment

Structural details
The main construction features are summarized below; confirm the final arrangement for the selected model.
Quick structural highlights
- 01 Selected material: Hastelloy C, titanium alloy and other materials according to the medium.
- 02 Centerline casing support: OH2 support arrangement.
- 03 Monitoring interfaces: connections for temperature and liquid-leakage probes and alarm.
Product information
| Product name | MCHD magnetic-drive multifunctional low-flow, high-head chemical process pump |
|---|---|
| Model | MCHD |
| Brand | Jiangsu Wuxin Pump Industry Co., Ltd. |
| Dimensions | Customized to requirements |
| Origin | Jingjiang, Jiangsu |
Confirm the final configuration against the selected model documentation.
Model identification (series example; final order specification is confirmed by selection)
MCHD-40-250G
- MCHD
- Magnetic-drive multifunctional low-flow, high-head chemical process pump series designation
- -40
- Suction and discharge size, mm
- -250
- Rated pump head, m
- G
- High-temperature code; marked for ≥110-350 °C, no code at ≤110 °C
Performance parameter ranges
| Outlet size | DN25~DN65 mm |
|---|---|
| Flow | 1.6~20 m³/h |
| Head | 150~320 m |
| Pressure rating | 2.5~5 MPa |
| Speed | 2900 r/min |
| Power | 18.5~160 kW |
| Operating temperature | -45~350 °C |
These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.
Application range
For low-flow, high-head duties including gas-liquid entrainment and transfer, low-level lifting, unloading and long-distance high-pressure transfer.
Suitable media include flammable, explosive, volatile, easily vaporized, toxic and corrosive media, and clean media with kinematic viscosity not exceeding 400 cSt at the transfer temperature.
Some duties can replace vacuum, high-pressure, self-priming or long-shaft sump pumps. Confirm each substitution for the actual duty; it is not a general cross-family guarantee.
Working conditions
| Operating temperature range | -45~350 °C |
|---|---|
| Operating pressure rating | 2.5~5 MPa |
| Configuration | Customizable to requirements |
Operating temperature and pressure ratings are series ranges; confirm the permissible values for the selected model documentation.
MCHD working equipment and arrangement

Structural design features
- The inlet is at the highest point of the casing with axial suction and radial discharge. The casing can retain liquid to support rapid self-priming and reduce damage risk when the chamber lacks liquid.
- An integrated multifunctional single-stage impeller supports gas-liquid entrainment and high head. Self-priming can extract more than 45% gas and achieve a maximum vertical suction lift of 8 m.
- The meshing volute passage and dual-function compound impeller are matched to reduce axial and radial forces and improve running stability.
Bearings, heat dissipation and monitoring
- SKF bearings have a design service life of approximately 25,000 hours.
- A multi-fin oil-bath-lubricated bearing housing helps improve heat dissipation and bearing life.
- Interfaces are reserved for temperature and liquid-leakage probes and an alarm; a monitoring and protection system can be configured.
Product overview
MCHD Magnetic-Drive Multifunctional Low-Flow, High-Head Chemical Process Pump
The MCHD magnetic-drive multifunctional low-flow, high-head chemical process pump uses a single-stage, single-suction horizontal design with centerline casing support (OH2) for low-flow, high-head duties.
The manual describes petroleum, chemical, coal-chemical, pharmaceutical, military, nuclear, electronics and semiconductor industries, including flammable, explosive, highly toxic and easily vaporised liquids. It is for small-flow, high-head duties and can convey clean media or media with viscosity not exceeding 400 cSt.
Technical parameters
| Pump type | Small-flow, high-head magnetic-drive chemical process pump |
|---|---|
| Conventional casing materials | 304 and 316LNote · Conventional options in the manual parts table; confirm for the medium |
| Conventional impeller materials | 2205 and 2507Note · Conventional options in the manual parts table |
| Journal bearing and sleeve | SSiC and W7Note · Final configuration depends on duty |
| Containment shell | 304 or 316L with C276 optionsNote · Use the order and material confirmation documents |
Selection guidance
- Medium name, composition, concentration, density and viscosity
- Normal, minimum and maximum medium temperature
- Required flow, head, system pressure and available NPSH
- Solids content, particle size and hardness, and crystallization tendency
- Installation arrangement, ambient conditions, power supply and protection requirements
Operating notes
- Do not treat the limits of a series range as one duty point available from every size.
- Compatibility with wetted, bearing, seal or containment materials must be reviewed for the actual medium and duty.
- Start-up, shutdown, valve operation and maintenance must follow the latest manual for the exact model.
- Small flow and high head describe the series; the final duty point must be checked on the performance curve.
- Hazardous media, valve position, material choice, dry running and piping configuration are operating-risk controls.
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.