MYD Magnetic-Drive Vertical Sump Pump
Product inquiry: 0523-84832479Product introduction
Flow: 1.6~1000 m³/h; head: 5~1000 m; working temperature: -45~120°C; pressure class: 2.5~10 MPa. The VS4 single-stage, single-suction or multistage vertical submerged design uses Morse-taper sectional shaft connections selected for the submerged depth, with a submerged length of up to 10 m. Bearings support both ends of each support tube to help control shaft axial and radial forces. Radial sealing rings and axial gaskets form a double-seal arrangement that keeps the medium away from the shaft and bearings; a double containment shell and containment-shell leakage monitoring and alarm device can be configured.
Product presentation

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
Specific configuration and suitable operating conditions are subject to selection confirmation.
Structural Design Features
- VS4 single-stage or multistage, single-suction, vertical submerged construction.
- The shaft uses sectional assemblies with Morse-taper sleeve connections selected for the submerged depth, with a submerged length of up to 10 m.
- Bearings at both ends of each support-pipe section carry axial and radial forces generated during shaft operation.
- Radial sealing rings and axial gaskets provide double sealing, keeping the medium from direct contact with the shaft and bearings.
- A double containment shell and containment-shell leakage monitoring and alarm device are available to improve leakage protection if the shell is damaged.
MYD Series Structure Diagram

Model Identification
MYD50-12525X5
- MYD
- Magnetic-drive multistage long-shaft sump pump
- 50
- Design-point flow rate (m³/h)
- -125
- Design-point head (m)
- 25
- Single-stage head (m)
- X5
- Number of impeller stages
Performance Parameter Ranges
Configurable to requirements
| Product name | MYD magnetic-drive vertical sump pump | Brand | Jiangsu Wuxin Pump Co., Ltd. |
|---|---|---|---|
| Outlet size | DN25~DN300 mm | Pressure class | 2.5~10 MPa |
| Flow | 1.6~1,000 m³/h | Speed | 1,450 / 2,900 r/min |
| Head | 5~1,000 m | Operating temperature | −45 to 120°C |
| Power | 1.5~560 kW | Submerged length | 0.5~10 m |
Note: The values above are series reference ranges; refer to the selected model and supplied technical documentation for actual parameters.
Main Applications
For conveying flammable, explosive, volatile, toxic or corrosive media from low liquid levels and sealed vessels.
Suitable for petroleum, chemical, nuclear, coal-chemical, refining, natural-gas processing, chemical-fibre, papermaking, military, metallurgy, electroplating, pharmaceutical, food-processing, electronics, semiconductor and environmental-protection industries. The medium should be clean or contain only a small amount of non-ferrous particles.
Selection and Ordering Inputs
MYD pumps are selected according to submerged depth, medium properties and system conditions. Before ordering, provide the following operating parameters so that wetted-part materials, submerged-section configuration and accessories can be confirmed.
- Medium name and specific gravity;
- Presence, content, particle size and hardness of solids;
- Medium viscosity;
- Working environment and temperature;
- Medium composition and concentration;
- Required flow and head;
- NPSH available at the installation.
Special operating conditions can be reviewed for a tailored pump structure; installation dimensions are provided with the order drawings.
Operating Boundaries
Installation, operation and maintenance should follow the product manual and supplied technical documentation. Confirm the following boundaries during selection and use:
- Do not run the pump dry; starting and stopping with the discharge valve closed, and the permitted duration, must follow the manual;
- Before starting, confirm that the rotation direction matches the pump rotation mark; reverse rotation will damage the pump. Do not operate with gas mixed into the medium;
- Discharge pressure must not exceed the pressure limit stated in the manual; flow must remain within the range stated in the manual and performance test data sheet;
- Liquid temperature during start-up, shutdown and operation, and the required configuration, must be confirmed for the specific model and supplied technical documentation.
Product information
| Model designation | MYD Magnetic-Drive Vertical Sump Pump |
|---|---|
| Catalog category | Metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.