MJF Magnetic-Drive Horizontal Slurry Vacuum Chemical Pump
Product inquiry: 0523-84832479Product introduction
The MJF magnetic-drive horizontal slurry vacuum chemical pump uses a single-stage, single-suction horizontal arrangement. Its annular-flow volute and open impeller are intended for slurries containing solids; an inducer at the inlet improves cavitation performance and reduces required NPSH.
Lubrication and cooling of the magnetic-drive section can use internal medium circulation or an external liquid loop according to solids content. The isolation sleeve, pump cover and anti-return-ring assembly support coolant circulation and protection of the magnetic-drive components. Confirm materials, shaft arrangement and duty against the selected model documentation.
Product presentation
MJF magnetic-drive horizontal slurry vacuum chemical pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability labels summarize the series; suitability depends on the selected model and duty.
Model identification (series example; confirm the ordered specification during selection)
MJF50-10-25DG
- MJF
- Magnetic-drive slurry negative-pressure pump series code
- 50
- Inlet size, in mm
- -10
- Flow, in m³/h; example value
- -25
- Head, in m; example value
- D
- Close-coupled designation; shaft-coupled versions use a coupling and normally omit this code
- G
- High-temperature code
Structural overview
Single-stage, single-suction, horizontal design. The annular-flow volute and open impeller are intended to convey slurries containing solid particles while reducing the risk of flow-passage blockage.
An inducer at the inlet is intended to improve cavitation performance and reduce required NPSH. Confirm the permitted duty against the medium, temperature and installation conditions.
Complete MJF pump assembly with 01/02/03 callouts

Structural details
The main construction features are summarized below; confirm the final arrangement for the selected model.
Structural highlights
- 01 Selected materials: 304, 316L, Hastelloy C, titanium alloy and others; confirm each material against the medium, concentration, temperature and construction.
- 02 Product structure: single-stage, single-suction horizontal arrangement. Confirm coupling, base and installation dimensions when direct-coupled or shaft-coupled versions are selected.
- 03 Design feature: an annular-flow volute with open impeller helps reduce flow-passage blockage when conveying slurries containing solids.
Product information
| Product name | MJF magnetic-drive horizontal slurry vacuum chemical pump |
|---|---|
| Model | MJF |
| Brand | Jiangsu Wuxin Pump Industry Co., Ltd. |
| Dimensions | Customized to requirements |
| Origin | Jingjiang, Jiangsu |
Confirm the final configuration against the selected model documentation.
Performance parameter ranges
| Inlet size | DN25~DN125 mm |
|---|---|
| Speed | 1450/2900 r/min |
| Flow | 1.5~200 m³/h |
| Power | 0.55~110 kW |
| Head | 4~50 m |
| Operating temperature | -45~200 °C |
| Pressure rating | 1.6 MPa |
These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.
Application range
For chemical, pharmaceutical, papermaking, metallurgical, food, environmental-protection and pesticide industries, conveying media containing solid particles that may also be corrosive, flammable, explosive, toxic, volatile or high-value. Also identified for duties with low available NPSH.
Confirm suitability against medium composition, solids content, temperature, available NPSH, material compatibility and site safety requirements. Industry examples do not establish compatibility with every medium or authorize substitution.
Working conditions
| Speed | 1450/2900 r/min |
|---|---|
| Flow range | 1.5~200 m³/h |
| Head range | 4~50 m |
| Operating temperature | -45~200 °C |
| Pressure rating | 1.6 MPa |
| Configuration | Customizable to requirements |
These are series ranges. No individual pump is assumed to combine every upper limit across all media, temperatures, pressures and flow points; confirm the permitted range and configuration against the selected model documentation.
MJF working-condition pump arrangement

Structural design features
- Single-stage, single-suction, horizontal design.
- An annular-flow volute and open impeller reduce flow-passage blockage when conveying slurries containing solid particles.
- An inlet inducer improves cavitation performance and reduces required NPSH.
- Depending on solids content, the magnetic-drive section can use medium self-lubrication with internal circulation or external liquid lubrication and cooling with external circulation.
- The non-metallic isolation sleeve is designed for 1.6 MPa, has relatively low magnetic eddy-current loss and has little effect on coolant temperature rise.
- A vane-type anti-return-ring assembly in the middle section behind the pump cover can increase coolant circulation velocity and support cooling and lubrication of the magnetic-drive components.
Product information
| Model designation | MJF Magnetic-Drive Horizontal Slurry Vacuum Chemical Pump |
|---|---|
| Catalog category | Metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.