Products

MCZ Magnetic-Drive Chemical Process Pump

Home > Products > MCZ Magnetic-Drive Chemical Process Pump

MCZ Magnetic-Drive Chemical Process Pump

Product inquiry: 0523-84832479

Product introduction

The MCZ magnetic-drive standard chemical process pump combines the casing and impeller of a CZ standard chemical pump with a magnetic-drive unit in a static-sealing arrangement. The motor rotates the outer magnet rotor; the permanent magnetic field crosses the isolation sleeve and the gap between the inner and outer rotors, transmitting torque so that the shaft, impeller and inner rotor rotate together.

The isolation sleeve keeps the conveyed medium inside the pump chamber and out of contact with the surrounding space. Magnetic drive replaces the moving shaft seal used by packed or mechanical-seal designs. Zero-leakage wording describes this relative design intent; sealing integrity still depends on the isolation sleeve, seals, correct selection and maintenance.

Product presentation

MCZ magnetic-drive chemical process pump

MCZ magnetic-drive chemical process pump on a blue diagonal stage, showing the Jiangsu Wuxin Pump Industry Co., Ltd. name, thirty-years slogan, MCZ lettering, WUXIN PUMP wordmark, stainless-steel casing, yellow coupling guard, green motor and complete baseplate.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These capability labels summarize the series; suitability depends on the selected model and duty.

Structural overview

Single-stage, single-suction, horizontal design with casing-foot support (OH1). Confirm materials, isolation-sleeve arrangement, bearings and monitoring against the selected model documentation.

MCZ pump train and key features

MCZ magnetic-drive chemical process pump in oblique view, showing the suction and discharge flanges, stainless-steel casing, yellow coupling guard, green motor, baseplate, and the selected-material, product-structure and product-advantage indicators.

Structural details

The main construction features are summarized below; confirm the final arrangement for the selected model.

Structural highlights

  • 01 Selected material: 0Cr18Ni9Ti (304), 0Cr18Ni12Mo2Ti (316L), 1Cr13 and CS. Final wetted materials must be selected for medium compatibility.
  • 02 Product structure: single-stage, single-suction, horizontal design.
  • 03 Product advantage: attractive appearance, compact construction and economical value; confirm performance and configuration for the selected model.

Product information

MCZ product information
Product nameMCZ magnetic-drive chemical process pump
ModelMCZ
BrandJiangsu Wuxin Pump Industry Co., Ltd.
DimensionsCustomized to requirements
OriginJingjiang, Jiangsu

Confirm the final configuration against the selected model documentation.

Model identification (series example; final order specification is confirmed by selection)

MCZ100-65-315A

MCZ
Magnetic-drive chemical process pump series designation
100
Suction size, mm
-65
Discharge size, mm
-315
Nominal impeller diameter, mm
A
Impeller trim code A, B, C, D, ...

Performance ranges

MCZ series ranges
Outlet sizeDN32~DN300 mm
Flow6~2000 m³/h
Head3~135 m
Pressure rating2.5 MPa
Speed1450/2900 r/min
Power0.55~250 kW
Operating temperature-80~250 °C

These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.

Application range

For low- or high-flow, high-head and low-NPSH duties, including high- or low-temperature service. Suitable media include clean media prone to crystallization or solidification; flammable, explosive, easily vaporized, volatile, highly toxic, corrosive or valuable media; and media containing a small amount of non-ferrous fine particles.

Suitability also depends on concentration, temperature, particle conditions, available NPSH, isolation-sleeve design and wetted materials. Series identity or industry examples do not establish compatibility for every duty.

Working conditions

MCZ series working conditions
Working flow range6~2000 m³/h
Working head range3~135 m
Pressure rating2.5 MPa
Speed1450/2900 r/min
Operating temperature-80~250 °C
ConfigurationCustomizable to requirements

Working ranges, customizable configuration and individual guarantees are different scopes. Confirm the actual flow, head, pressure, temperature, medium and installation before ordering; do not treat overview values as an operating permit.

MCZ working-condition equipment

Complete MCZ magnetic-drive chemical process pump in a working-condition photograph, showing the suction flange, casing, coupling, yellow guard, green motor, all mounting feet and complete white baseplate against a blue background and light-gray floor.

Structural design features

  • Single-stage, single-suction, horizontal design with casing-foot support (OH1).
  • Floating impeller: hydraulic action balances most axial thrust; a flat thrust bearing carries the remainder.
  • SKF bearings have a design service life of approximately 25,000 hours. Actual life depends on load, lubrication, installation, maintenance and operating conditions.
  • A multi-fin oil-bath-lubricated bearing housing helps dissipate heat and support bearing life.
  • Interfaces are reserved for temperature and liquid-leakage probes, with dry-run and overload-power protection available as configured options. Confirm the protection package at ordering.
  • A double isolation sleeve is available to improve leakage protection if a sleeve is damaged. Confirm whether it is supplied and whether the arrangement suits the duty.

Product information

Model designationMCZ Magnetic-Drive Chemical Process Pump
Catalog categoryMetal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Should metal magnetic-drive pump selection start with a model or the duty?

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.