IMCZ-G High-Temperature Magnetic-Drive Chemical Process Pump
Product inquiry: 0523-84832479Product introduction
The IMCZ magnetic-drive standard chemical process pump combines the casing and impeller of a CZ standard chemical pump with a magnetic-drive unit in a static-sealing arrangement; the catalog model is the IMCZ-G high-temperature magnetic-drive chemical process pump.
Magnetic drive transmits torque through the isolation sleeve and the gap between the inner and outer magnet rotors, eliminating the conventional moving shaft seal. Confirm the temperature rating, heating or cooling jacket, bearings and isolation-sleeve arrangement against the selected model and actual duty.
Product presentation
IMCZ-G magnetic-drive chemical process pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability labels summarize the series; suitability depends on the selected model and duty.
Structural overview
Single-stage, single-suction, horizontal design with casing-foot support (OH1). Confirm the dual-chamber heating and cooling assembly, plain bearings and lubrication for the actual high-temperature duty and selected model.
IMCZ-G pump train and key features

Structural details
The main construction features are summarized below; confirm the final arrangement for the selected model.
Structural highlights
- 01 Selected material: 0Cr18Ni9Ti (304), 0Cr18Ni12Mo2Ti (316L), 1Cr13 and CS. Final wetted materials must be selected for medium and temperature conditions.
- 02 Product structure: single-stage, single-suction, horizontal design.
- 03 Product advantage: plain bearings at both ends provide stable support and smooth operation; confirm the bearing arrangement and operating limits for the selected model.
Product information
| Product name | IMCZ-G magnetic-drive chemical process pump |
|---|---|
| Model | IMCZ-G |
| Brand | Jiangsu Wuxin Pump Industry Co., Ltd. |
| Dimensions | Customized to requirements |
| Origin | Jingjiang, Jiangsu |
Confirm the final configuration against the selected model documentation.
Model identification (series example; final order specification is confirmed by selection)
IMCZ100-50-315A-G
- IMCZ
- Magnetic-drive chemical process pump series designation
- 100
- Suction size, mm
- -50
- Discharge size, mm
- -315
- Nominal impeller diameter, mm
- A
- Impeller trim code A, B, C, D, ...
- -G
- High-temperature code
Performance ranges
| Outlet size | DN32~DN300 mm |
|---|---|
| Flow | 6~2000 m³/h |
| Head | 3~135 m |
| Pressure rating | 2.5 MPa |
| Speed | 1450/2900 r/min |
| Power | 0.55~250 kW |
| Operating temperature | ≥110~350 °C |
These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.
Application range
For low- or high-flow, high-head and low-NPSH duties, including high- or low-temperature service. Suitable media include clean media prone to crystallization or solidification; flammable, explosive, easily vaporized, volatile, highly toxic, corrosive or valuable media; and media containing a small amount of non-ferrous fine particles.
High-temperature service also requires review of medium thermal stability, material compatibility, heating or cooling, available NPSH and isolation-sleeve temperature. Series identity or industry examples do not establish suitability for every duty.
Working conditions
| Working flow range | 6~2000 m³/h |
|---|---|
| Working head range | 3~135 m |
| Pressure rating | 2.5 MPa |
| Speed | 1450/2900 r/min |
| Operating temperature | ≥110~350 °C |
| Configuration | Customizable to requirements |
Working ranges, customizable configuration and individual guarantees are separate scopes. The high-temperature series data is listed from ≥110 °C in this table; confirm the permitted range, configuration and individual guarantee against the actual duty and technical agreement before ordering.
IMCZ-G working-condition equipment

Structural design features
- Single-stage, single-suction, horizontal design with casing-foot support (OH1).
- SKF bearings have a design service life of approximately 25,000 hours. Actual life depends on high-temperature load, lubrication, installation, maintenance and operating conditions.
- A dual-chamber heating and cooling assembly uses internal circulation to cool the plain bearings and isolation sleeve and remove bearing friction heat and sleeve eddy-current heat. The jacket can be configured with single- or double-layer insulation for heating or cooling.
- Plain bearings at both ends provide stable support; confirm the bearing arrangement and cooling circuit for the selected configuration.
- The grease-lubricated bearing housing has a large grease capacity. Under the specified speed, temperature and maintenance conditions, it can operate for approximately 3,000 hours without replenishing or changing grease, which reduces maintenance frequency. This is a qualified statement, not a maintenance-free operating promise.
- Interfaces are reserved for temperature and liquid-leakage probes, with dry-run and overload-power protection available as configured options. Confirm the protection package at ordering.
- A double isolation sleeve is available to improve leakage protection if a sleeve is damaged. Confirm whether it is supplied and whether the arrangement suits the duty.
Product information
| Model designation | IMCZ-G High-Temperature Magnetic-Drive Chemical Process Pump |
|---|---|
| Catalog category | Metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.