CQB-L/CQB-H Magnetic-Drive Centrifugal Pump
Product inquiry: 0523-84832479Product introduction
The CQB-L and CQB-H magnetic-drive centrifugal pumps use a single-stage, single-suction, horizontal configuration. Their external mounting dimensions match the IH chemical centrifugal pump, and an IH mechanical seal of the same size can be interchanged according to the selected model.
Product presentation
CQB-L/CQB-H magnetic-drive centrifugal pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These product capabilities are an overview; confirm performance for the selected model and duty.
Model identification (series example; confirm the ordered specification during selection)
CQB50-32-160L
- CQB
- Magnetic-drive stainless-steel centrifugal pump series code
- 50
- Pump inlet size, in mm
- -32
- Pump outlet size, in mm
- -160
- Nominal impeller diameter, in mm
- L
- Shaft-coupled construction code; H denotes environmentally friendly construction
CQB-L/CQB-H two-pump equipment arrangement

Structural design features
- The CQB-L and CQB-H use a single-stage, single-suction, horizontal arrangement. Single or dual plain bearings are matched to flow, head and power.
- The CQB-L bearing housing uses oil-bath-lubricated bearings.
- The CQB-H bearing housing uses grease-lubricated bearings. Select the model according to site safety, environmental and operating conditions.
- Single or dual plain bearings are matched to flow, head and power. Components within the series offer commonality and interchangeability for spare-parts stocking and maintenance.
- PTFE auxiliary gaskets accommodate a range of chemical-duty conditions; confirm compatibility for the specific medium.
Product information
Product name: CQB-L/CQB-H magnetic-drive centrifugal pump.
Models: CQB-L, CQB-H.
Pump structure: single-stage, single-suction, horizontal.
External mounting dimensions: match the IH chemical centrifugal pump. Mechanical seal interchangeability: an IH pump mechanical seal of the same size can be interchanged with the CQB-L or CQB-H pump.
Main materials: 304, 316L, Hastelloy C and titanium alloy, selected according to the medium and configuration.
Dimensions: customized to customer requirements.
Ambient conditions: ambient temperature ≤ 40 °C; relative humidity ≤ 95%.
Brand: Jiangsu Wuxin Pump Industry Co., Ltd.
Place of origin: Jingjiang, Jiangsu, China.
External mounting dimensions match the IH chemical centrifugal pump, while configured dimensions are customized to customer requirements. Confirm both against the selected-model drawing before ordering.
Performance parameter range
| Performance parameter range | |
|---|---|
| Inlet size | DN25~DN125 mm |
| Flow | 0.8~200 m³/h |
| Head | 5~80 m |
| Pressure class | 1.6 MPa |
| Maximum working pressure | Maximum allowable inlet pressure + pump design pressure ≤ 1.6 MPa |
| Speed | 1,450/2,900 r/min |
| Power | 0.55~75 kW |
| Operating temperature | -100~250 °C |
The values are series ranges; one pump does not necessarily span every limit. Confirm actual performance, materials and mounting dimensions against the selected model and supplied technical documentation.
Application range
Applications include chemical processing, pharmaceuticals, food, chemical fibers, biotechnology, environmental protection, agrochemicals and new energy. The pumps are intended for flammable, explosive, toxic, volatile, corrosive and high-value media, as well as clean media or media containing a small amount of non-ferromagnetic particles. Confirm suitability for the actual medium and operating conditions.
Industries served: Chemical processing, pharmaceuticals, food, chemical fibers, biotechnology, environmental protection, agrochemicals and new energy
Working-condition equipment and common base

Selection and ordering inputs
Selection must consider the medium, duty and installation together, with the selected-model technical documentation as the final reference. Before ordering, provide:
- Medium name, composition, concentration and density;
- Medium temperature, required flow and head;
- Particle content, size and properties;
- Allowable system inlet pressure and working pressure;
- Site ambient temperature, relative humidity and installation dimensions;
- CQB-L or CQB-H lubrication arrangement.
Interchangeability with an IH mechanical seal of the same size does not authorize installation without dimensional verification. Confirm the seal, materials and configuration for the order.
Use and operating boundaries
Confirm medium compatibility, temperature and pressure against the material, model and site conditions:
- A restriction on ferromagnetic particles does not make every particle-bearing medium suitable; declare fine particles when ordering.
- Flammable, explosive, toxic and volatile media require suitable site safety, environmental and regulatory measures.
- The series range does not replace an individual performance curve, allowable operating range or the supplied technical documentation.
Product overview
CQB-L/CQB-H Magnetic-Drive Centrifugal Pump
Applications include chemical processing, pharmaceuticals, food, chemical fibers, biotechnology, environmental protection, agrochemicals and new energy. The pumps are intended for flammable, explosive, toxic, volatile, corrosive and high-value media, as well as clean media or media containing a small amount of non-ferromagnetic particles. Confirm suitability for the actual medium and operating conditions.
Technical parameters
| Product name | CQB-L/CQB-H magnetic-drive centrifugal pump |
|---|---|
| Product models | CQB-L, CQB-H |
| Pump structure | Single-stage, single-suction, horizontal |
| External mounting dimensions | Match the IH chemical centrifugal pump |
| Mechanical seal interchangeability | An IH pump mechanical seal of the same size can be interchanged with the CQB-L or CQB-H pump |
| Inlet size | DN25~DN125 mm |
| Series flow range | 0.8~200 m³/hNote · Series range, not a single-size duty point |
| Series head range | 5~80 mNote · Series range; confirm the individual duty against the performance curve |
| Pressure class | 1.6 MPa |
| Maximum working pressure | Maximum allowable inlet pressure + pump design pressure ≤ 1.6 MPaNote · State the system working pressure when ordering |
| Speed | 1,450/2,900 r/min |
| Power | 0.55~75 kW |
| Operating temperature | -100~250 °CNote · Series range; confirm applicability against the material, medium and selected model |
| Ambient conditions | Ambient temperature ≤ 40 °C; relative humidity ≤ 95% |
| Main materials | 304, 316L, Hastelloy C, titanium alloyNote · Select according to the medium and configuration |
| Product dimensions | Customized to customer requirementsNote · Confirm the configured dimensions before ordering |
| Place of origin | Jingjiang, Jiangsu, China |
| Brand | Jiangsu Wuxin Pump Industry Co., Ltd. |
Selection guidance
- Medium name, composition, concentration, density and viscosity
- Normal, minimum and maximum medium temperature
- Required flow, head, system pressure and available NPSH
- Solids content, particle size and hardness, and crystallization tendency
- Installation arrangement, ambient conditions, power supply and protection requirements
Operating notes
- Do not treat the limits of a series range as one duty point available from every size.
- Compatibility with wetted, bearing, seal or containment materials must be reviewed for the actual medium and duty.
- Start-up, shutdown, valve operation and maintenance must follow the latest manual for the exact model.
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.