CQB-D Magnetic-Drive Centrifugal Pump
Product inquiry: 0523-84832479Product introduction
The CQB-D magnetic-drive centrifugal pump uses a single-stage, single-suction close-coupled arrangement with the pump and motor mounted together on a short base. It is intended for medium transfer across chemical, pharmaceutical, food and new-energy applications.
Confirm the specific model and ordering code against the selected model documentation.
Product presentation
CQB-D magnetic-drive centrifugal pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability labels summarize the series; suitability depends on the selected model and duty.
Model identification (series example; confirm the ordered specification during selection)
CQB50-32-160DG
- CQB
- Magnetic-drive stainless-steel centrifugal pump series code
- 50
- Pump inlet size, in mm
- -32
- Pump outlet size, in mm
- -160
- Nominal impeller diameter, in mm
- D
- Close-coupled pump construction code; L denotes shaft-coupled construction and H denotes environmentally friendly construction
- G
- High-temperature code (medium temperature above 100~180 °C)
CQB-D pump assembly close-up
Single-stage, single-suction close-coupled construction with the pump and motor mounted together on a short base.
The close-up shows the pump, magnetic drive, bearing and motor relationships. Performance values are listed in the table below.
CQB-D pump assembly close-up

Product information
| Product name | CQB-D magnetic-drive centrifugal pump |
|---|---|
| Product model | CQB-D |
| Brand | Jiangsu Wuxin Pump Industry Co., Ltd. |
| Dimensions | Customized to requirements |
| Place of origin | Jingjiang, Jiangsu |
These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.
Performance ranges
| Suction opening | DN25~DN100 mm |
|---|---|
| Flow | 0.8~100 m³/h |
| Head | 5~80 m |
| Pressure rating | 1.6 MPa |
| Speed | 1450/2900 r/min |
| Power | 0.55~55 kW |
| Operating temperature | −40~200 °C |
These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.
Working conditions
| Flow range | 0.8~100 m³/h |
|---|---|
| Head range | 5~80 m |
| Pressure rating | 1.6 MPa |
| Speed | 1450/2900 r/min |
| Operating temperature | −40~200 °C |
These are series working ranges. A single pump does not become suitable for every medium, temperature and duty point merely because it is within these limits.
CQB-D working-condition pump assembly

Application range
For chemical, pharmaceutical, food, chemical-fiber, biotechnology, environmental-protection, pesticide and new-energy sectors, handling flammable, explosive, toxic, volatile, corrosive and high-value media, as well as clean media or media containing a small amount of non-ferromagnetic particles.
Confirm suitability against the medium and duty conditions. Clean media and media containing a small amount of non-ferromagnetic particles remain two separate application cases.
Structural design features
- Single-stage, single-suction close-coupled construction, with the pump and motor mounted together on a short base.
- The compact unit requires little floor space and runs smoothly with relatively low noise.
- A single or double plain-bearing arrangement is matched to flow, head and power. Components within the series are designed for good commonality and interchangeability.
- PTFE auxiliary gaskets are listed for a range of chemical duties; suitability must be confirmed for the specific medium.
- The design facilitates maintenance and component replacement.
- The series also includes a silica-sol precision-cast hydraulic model and wetted materials that can include 0Cr18Ni9 (304), 0Cr17Ni12Mo2 (316L) and 0Cr18Ni16Mo5 (317), with JB/T 7742 cited as the execution standard. Material suitability remains subject to the medium and selected configuration.
Multi-angle view 1: complete front view

Multi-angle view 2: pump end and motor connection

Multi-angle view 3: complete oblique view

Product information
| Model designation | CQB-D Magnetic-Drive Centrifugal Pump |
|---|---|
| Catalog category | Metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.