Products

IM and IM-G Magnetic-Drive Chemical Pumps

Home > Products > IM and IM-G Magnetic-Drive Chemical Pumps

IM and IM-G Magnetic-Drive Chemical Pumps

Product inquiry: 0523-84832479

Product introduction

The IM-G series is a multi-tube, high-temperature magnetic-drive pump with a single-stage, single-suction design. Its rated-performance dimensions follow ISO 2858 and ISO 3661, and the installation is described as interchangeable with the IH chemical pump.

Product presentation

IM and IM-G magnetic-drive chemical pumps

IM and IM-G magnetic-drive chemical pump assembly, including the pump, coupling and motor.
  • High temperature
  • Mechanical strength
  • Long service life
  • Broad applications

Confirm final performance and configuration against the selection documents.

Structural overview

Single-stage, single-suction, horizontal design with casing-foot support (OH1).

The multi-tube assembly uses internal circulation to remove plain-bearing friction heat and isolation-sleeve eddy-current heat. Single or double jackets can be configured for heating or cooling with hot water, steam, heat-transfer oil or cold water.

IM / IM-G structure and assembly relationships

IM and IM-G magnetic-drive chemical pump assembly showing the suction inlet, discharge flange, casing, coupling, guard, motor and base.

Structural components

The magnetic drive uses high-performance samarium-cobalt permanent magnets, and the back-pull-out construction provides access to the rotor assembly for maintenance.

Structural highlights

  • 01 Selected materials: 304, 316L, Hastelloy C and titanium alloy, selected for the medium.
  • 02 Back-pull-out construction: removing the coupling spacer allows the rotor assembly to be withdrawn for maintenance.
  • 03 Magnetic drive: uses high-performance samarium-cobalt permanent magnets.

Product information

IM and IM-G product information
Product nameIM and IM-G magnetic-drive chemical pumps
Product modelsIM-G / IM
BrandJiangsu Wuxin Pump Industry Co., Ltd.
DimensionsCustomized to customer requirements
OriginJingjiang, Jiangsu

Confirm the final configuration against the selected model documentation.

Model identification (series example; final order specification is confirmed by selection)

IM100-65-200AG

IM
International-standard magnetic-drive chemical process pump series designation
100
Suction size, mm
-65
Discharge size, mm
-200
Nominal impeller diameter, mm
A
Impeller trim code A, B, C or D
G
High-temperature code

Performance ranges

IM and IM-G series performance parameters
Outlet sizeDN25~DN200 mm
Flow0.8~400 m³/h
Head5~125 m
Pressure rating1.6 MPa
Speed1450/2900 r/min
Power0.55~250 kW
Operating temperatureIM-G: 110~350 °C; IM: −45~100 °C

The values are series ranges. The IM-G and IM temperature ranges differ and must not be interchanged. Confirm the final parameters against the selected model documentation.

Application range

For chemical media that are hot, easily vaporized or prone to crystallization at low temperature, as well as flammable, explosive, volatile, highly toxic, corrosive or high-value media.

Confirm medium compatibility, temperature, viscosity, NPSH and material configuration for the selected model.

Working conditions

Working-condition parameters
Operating temperatureIM-G: 110~350 °C; IM: -45~100 °C
Liquid viscosityUp to 0.95 cP
ConfigurationCustomizable to requirements

Confirm the permitted temperature, viscosity and related configuration combination for the specific model and medium.

IM-G operating equipment and base

IM-G high-temperature magnetic-drive chemical pump showing the casing, flanges, coupling, guard, motor and base.

Material configuration

Material configuration
01 Wetted parts304, 316L, Hastelloy C and titanium alloy, selected for the medium.
02 Pump shaft07Cr15Ni7Mo2Al, 022Cr17Ni12Mo2Ti, 40Cr, 2Cr13 and Hastelloy C.
03 Isolation sleeve06Cr18Ni11Ti, 022Cr17Ni12Mo2Ti, Hastelloy C and alloy.
04 Shaft sleeve / wear ringTungsten carbide and pressureless-sintered silicon carbide; plain bearings may use tungsten carbide, F4-filled non-metal or pressureless-sintered silicon carbide.

Material options do not establish compatibility with a particular medium; confirm medium, concentration, temperature and construction.

Structural design features

  • 05 Back-pull-out construction: removing the coupling spacer allows the impeller and bearings to be serviced.
  • Plain bearings at both ends provide stable support.
  • The grease-lubricated bearing housing is described as running approximately 3,000 hours without grease replenishment under specified speed, temperature and maintenance conditions.
  • Temperature and liquid-leakage probe interfaces can support dry-run and overload-power protection.
  • A double isolation sleeve is available to improve leakage protection if the sleeve is damaged.

06 Magnetic drive

  • The IM-G high-temperature magnetic drive uses high-performance samarium-cobalt permanent magnets and is listed for service up to 350 °C.
  • Crystallized material can be heated into a liquid for transfer; the maximum liquid viscosity is 0.95 cP.

Product information

Model designationIM and IM-G Magnetic-Drive Chemical Pumps
Catalog categoryMetal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Should metal magnetic-drive pump selection start with a model or the duty?

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.