Product introduction

The MDDC is a BB4 end-suction, horizontal multistage magnetic-drive pump with segmented construction. Cooling equipment is generally unnecessary at medium temperatures up to 250 °C; a circulation cooling arrangement must be added for 250~350 °C. Confirm the configuration for the selected model.

Product presentation

  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

Confirm temperature, pressure and medium conditions for the final model.

Product overview and structural design

The MDDC uses a BB4 end-suction, segmented construction. A double containment shell can be specified, and temperature and liquid-leak probe connections are provided for dry-run and overload protection.

  • BB4 end-suction, multistage, segmented horizontal construction.
  • No cooling equipment is normally required up to 250 °C; add circulation cooling for 250~350 °C.
  • An optional double containment shell improves protection if the inner containment shell fails.
  • Temperature and liquid-leak probe connections are provided for optional dry-run and overload power protection.

The construction and auxiliary equipment are series statements. Installation, cooling and protection arrangements are defined by the selected model and supplied technical documentation.

MDDC horizontal multistage-section diagram

MDDC magnetic-drive end-suction multistage pump horizontal section diagram showing the complete axial suction inlet, multistage impellers and guide vanes, shaft, magnetic drive, bearing housing, discharge connection and horizontal base.

Structural and operating features

  • BB4 end-suction, multistage, segmented construction.
  • Optional double containment shell improves protection if the inner shell fails.
  • No cooling equipment is normally required below 250 °C; circulation cooling is required from 250~350 °C.
  • Temperature and liquid-leak probe connections support dry-run protection and overload power protection.

Model identification

MDDC100-200-50X4

MDDC
Magnetic-drive end-suction multistage pump
100
Design-point flow, in m³/h
-200
Design-point head, in m
-50
Head per stage, in m
X4
Number of impeller stages

Performance parameter ranges

MDDC series reference ranges, not a guarantee for one model or duty point
Performance parameter ranges
Discharge openingDN25~DN250 mm
Speed1450/2900 r/min
Flow1.5~700 m³/h
Power5.5~560 kW
Head5~1000 m
Pressure rating2.5~10 MPa
Operating temperature−45~350 °C

These ranges apply to the series and do not mean that one pump reaches every limit simultaneously. Confirm actual parameters, materials and permitted combinations from the selected model and supplied technical documentation.

Applications

Primarily for petroleum refining, petrochemicals, chemical processing and other industries, transferring solids-free petroleum, liquefied petroleum gas and other flammable, explosive or highly toxic media in high-temperature and high-pressure service.

  • Petroleum refining
  • Petrochemicals
  • Chemical processing
  • Liquefied petroleum gas transfer

Medium corrosiveness must be compatible with the wetted materials. Confirm medium temperature, pressure and permitted conditions for the final model.

Selection and ordering inputs

MDDC pumps are selected according to medium, temperature, pressure and the required flow and head. Provide the following information so that materials, cooling and protection arrangements can be confirmed.

  • Medium name, composition and concentration;
  • Medium temperature, specific gravity and viscosity;
  • Solids, gas or other special phases;
  • Required flow, head and pressure;
  • Available NPSH and installation conditions;
  • Cooling, thermal insulation and double-containment requirements;
  • Temperature, leak, dry-run and overload protection requirements.

Special conditions can be reviewed for a tailored construction. Order documentation defines installation dimensions and scope of supply.

Product name and application scope

The MDDC magnetic-drive end-suction multistage pump uses a BB4, segmented horizontal multistage construction for high-temperature, high-pressure clean-liquid service in petroleum refining, petrochemical and chemical industries.

Confirm materials, cooling arrangement, protection equipment and permitted operating conditions from the medium conditions, selected model and supplied technical documentation.

Product information

Model designationMDDC magnetic-drive end-suction multistage pump
Catalog categoryMetal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Should metal magnetic-drive pump selection start with a model or the duty?

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.