Product introduction

The DGCZ barrel-type double-casing multistage magnetic-drive pump uses a BB5, single-suction, multistage arrangement for high-head service in petrochemical, coal-chemical and related industries.

The medium is statically contained within the double casing by the containment shell, and power is transmitted through the inner and outer magnetic rotors. Confirm materials, protection options, installation dimensions and the operating point for the selected model and its technical documents.

Product presentation

  • High-temperature service
  • High mechanical strength
  • Long service life
  • Broad application range

These four capabilities describe series positioning and do not guarantee that every model meets them in every duty.

DGCZ double-casing multistage cross-section

Longitudinal cross-section of the DGCZ barrel-type double-casing multistage magnetic-drive pump, showing the double casing, two symmetrical impeller groups, staged diffusers, shaft, magnetic coupling, bearing housing, ports and base supports.

Model identification (series example; confirm the ordered specification by selection)

DGCZ46-500-50X10

DGCZ
Barrel-type double-casing multistage magnetic-drive pump series
46
Design-point flow, in m³/h
-500
Design-point head, in m
-50
Head per stage, in m
X10
Number of impeller stages; the example has 10 stages

Performance range

DGCZ series ranges, not a single-model guarantee
Performance range
Discharge sizeDN25~DN250 mm
Speed1450/2900 r/min
Flow3~700 m³/h
Power5.5~560 kW
Head5~1000 m
Pressure class2.5~16 MPa
Operating temperature−45~350 °C

These are DGCZ series ranges and do not mean that one pump simultaneously reaches every limit. Confirm performance, materials, protection, dimensions and motor selection against the selected model, medium and official technical documents.

Construction and advantages

  • BB5, single-suction, multistage construction.
  • The double casing, sectional combination volute and symmetrical impeller arrangement help balance axial force.
  • A spiral seal between the integrated spatial flow passage and the pump-shaft radial clearance helps eliminate residual unbalanced axial force.
  • SKF bearings have a stated design life of approximately 25,000 hours. The finned, oil-bath-lubricated bearing housing aids heat dissipation; design life is not a maintenance-free operating guarantee.
  • Interfaces are reserved for temperature and liquid-leak sensors and can be combined with dry-running and overload power protection.
  • An optional double containment shell can increase leakage protection if a containment shell is damaged.
  • Optional cooling or insulating jackets and electrical heat tracing can be selected to maintain medium temperature.

Application range

Suitable for high-head transfer in petrochemical, coal-chemical and related industries, including flammable, explosive, vaporizable, toxic or volatile hazardous media.

Medium compatibility, allowable temperature and pressure, protection devices and installation method must be confirmed for the selected model, materials and plant conditions. The series range is not a guarantee for any arbitrary medium or duty.

Selection and operating boundaries

The DGCZ pump uses the BB5 installation arrangement. Confirm the baseplate, piping interfaces and protection options for the selected model.

The example DGCZ 46-500-50X10 illustrates the model nomenclature. Confirm flow, head, head per stage and stage count against the actual curve, medium density and available NPSH.

Magnetic drive reduces rotating-seal leakage risk, but the containment shell, optional double containment, dry-running protection and overload protection must still be selected and maintained for the duty.

  • Confirm medium, concentration, temperature, density, viscosity, vapour pressure and solids.
  • Confirm design flow, head, available NPSH and continuous or intermittent duty.
  • Confirm power supply, speed, installation envelope, piping loads, monitoring interfaces and protection rating.
  • Use the final technical agreement, performance curve, bill of materials and supplied technical documents.

The ranges above do not replace individual selection calculations, a pump curve or an order-specific technical agreement.

Product information

Model designationDGCZ Barrel-Type Double-Casing Multistage Magnetic-Drive Pump
Catalog categoryMetal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Should metal magnetic-drive pump selection start with a model or the duty?

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.