CDYA magnetic-drive vertical multistage barrel pump
Product inquiry: 0523-84832479Product introduction
The CDYA is a single-suction, multistage vertical barrel pump with a magnetic drive that provides a static seal. It can be installed above ground or partially underground according to the required NPSH. Confirm the selected model, materials and installation method.
Product presentation
- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
Confirm medium, temperature and individual pump configuration during selection.
Product overview and structural design
The CDYA uses a VS6 vertical barrel arrangement. The guide vanes and impellers are made by silica-sol precision casting combined with high-frequency laser welding. A balance disc and magnetic levitation thrust-bearing assembly carry axial force.
- Single-suction, multistage vertical barrel construction; above-ground or semi-underground installation can be selected according to available NPSH.
- Guide vanes and impellers combine silica-sol precision casting and high-frequency laser welding for compact construction, smooth running, efficiency and energy savings.
- A balance disc and magnetic levitation thrust-bearing assembly carry axial force; the rotor forms an axial levitation state after start-up to reduce running wear.
- An optional double containment shell and leak-monitoring alarm improve protection in the event of an inner-shell failure.
- Cooling or thermal-insulation/heating jackets are available according to operating requirements.
These are series construction and optional configuration statements. The selected model and order documentation determine whether the double containment shell, monitoring alarm and jackets are supplied.
CDYA vertical barrel structure diagram

Structural features
- VS6, single-suction, multistage vertical barrel construction.
- Above-ground or semi-underground installation according to NPSH.
- Guide vanes and impellers made by silica-sol precision casting and high-frequency laser welding.
- A balance disc and magnetic levitation thrust-bearing assembly carry axial force; the rotor forms an axial levitation state after start-up.
- Optional double containment shell, containment-shell leak-monitoring alarm and cooling or thermal-insulation jackets.
Model identification
CDYA50-30030×10
- CDYA
- Magnetic-drive vertical multistage barrel pump
- 50
- Design-point flow, in m³/h
- -300
- Design-point head, in m
- 30
- Head per stage, in m
- ×10
- Number of impeller stages
Performance parameter ranges
| Performance parameter ranges | |
|---|---|
| Suction opening | DN25~DN250 mm |
| Speed | 1450/2900 r/min |
| Flow | 1.6~700 m³/h |
| Power | 0.75~560 kW |
| Head | 5~1000 m |
| Pressure rating | 2.5~16 MPa |
| Operating temperature | −45~350 °C |
The values are series ranges and do not mean that one pump reaches every limit simultaneously. Confirm actual performance, materials, installation dimensions and permitted conditions from the selected model and supplied technical documentation.
Applications
Suitable for chemical, petrochemical, pharmaceutical, defense, agricultural-chemical, metallurgical and environmental-protection applications, including transfer of flammable, explosive, volatile, toxic, corrosive and valuable media, pipeline boosting and installations with limited space.
- Chemical processing
- Petrochemicals
- Pharmaceuticals
- Defense industry
- Agricultural chemicals
- Metallurgy
- Environmental protection
Medium compatibility with the wetted materials, permitted temperature and pressure, and installation conditions must be confirmed for the final model.
Selection and ordering inputs
CDYA pumps are selected according to available NPSH, medium properties and required flow and head. Provide the following information so that the installation arrangement, materials and auxiliary equipment can be confirmed.
- Medium name, composition and concentration;
- Medium temperature, specific gravity and viscosity;
- Presence of solids, gas or crystallization;
- Required flow, head and pressure;
- Available NPSH at the installation;
- Installation arrangement, space limitations and cooling or insulation requirements;
- Containment-shell leak monitoring and dry-run or overload protection requirements.
Special conditions can be reviewed for a tailored construction. Order documentation defines installation dimensions and scope of supply.
Product name and application scope
The CDYA magnetic-drive vertical multistage barrel pump is used for chemical and related industrial liquid transfer and boosting.
Confirm medium compatibility, materials, installation arrangement and operating range from the duty conditions and supplied technical documentation before ordering.
Product information
| Model designation | CDYA magnetic-drive vertical multistage barrel pump |
|---|---|
| Catalog category | Metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Should metal magnetic-drive pump selection start with a model or the duty?
Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.
Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.