Product introduction

MZA and MZE magnetic-drive petrochemical process pumps combine ZA process-pump construction with magnetic drive for diverse petrochemical media. Confirm the support arrangement and configuration for the selected model.

Product presentation

MZA and MZE magnetic-drive petrochemical process pumps

MZA magnetic-drive petrochemical process pump brand visual showing the pump assembly, coupling guard, motor and base.
  • High- and low-temperature duties
  • Single-stage, single-suction horizontal design
  • Broad petrochemical process range
  • Oil-bath-lubricated bearing housing

Specific configuration and applicable operating conditions are subject to selection confirmation.

Structural overview

Single-stage, single-suction, horizontal design. OH1 and OH2 support arrangements distinguish the MZA and MZE models in the structural details.

MZA and MZE pump structure and equipment

Complete MZA and MZE magnetic-drive petrochemical process pump assembly, showing the suction inlet, casing, coupling guard, motor and mounting base.

Structural features

The pump uses modular construction and silica-sol investment casting for key components.

Quick structural highlights

  • 01 Selected material: Hastelloy C, titanium alloy and other materials according to the medium.
  • 02 Special process: the complete pump uses modular construction.
  • 03 High mechanical strength: silica-sol investment casting provides dense components, a clean external form and high hydraulic-model accuracy.

Product information

MZA and MZE product information
Product nameMZA and MZE magnetic-drive petrochemical process pumps
ModelMZA / MZE
BrandJiangsu Wuxin Pump Industry Co., Ltd.
DimensionsCustomized to requirements
OriginJingjiang, Jiangsu

Confirm the support arrangement and final configuration against the selected model documentation.

Model identification (series example; final order specification is confirmed by selection)

MZA(E)100-50-315A

MZA(E)
Magnetic-drive petrochemical process pump series designation
100
Suction size, mm
-50
Discharge size, mm
-315
Nominal impeller diameter, mm
A
Impeller trim code A, B, C, D, ...

Performance Parameter Ranges

Series coverage

Series performance parameters
Outlet sizeDN25~DN400 mm
Speed1450/2900 r/min
Flow4~2400 m³/h
Head4.5~260 m
Pressure rating2.5~10 MPa
Power0.55~630 kW
Operating temperature-80~250 °C

Note: These are series reference ranges. Refer to the selected model and the supplied technical documentation for actual parameters.

Application Range

Suitable for low- or high-flow, high-head and low-NPSH duties, as well as high- or low-temperature conditions. The pump can convey clean media that are prone to crystallization or solidification, flammable, explosive, easily vaporized, volatile, highly toxic, corrosive or valuable, and media containing a small amount of non-ferrous fine particles.

Referenced standards

Product design references standards including API 685 first edition, SH/T 3148-2007 and ISO 2858.

  • API 685, first edition: Sealless Centrifugal Pumps for Petroleum, Heavy Chemical, and Natural Gas Industry Applications.
  • SH/T 3148-2007.
  • ISO 2858.

Confirm applicable editions, clauses and actual conformity in the contract, technical agreement and final product documentation.

MZA working arrangement

MZA magnetic-drive petrochemical process pump showing the casing, upper flange, coupling guard, motor and base.

Structural Design Features

  • Single-stage, single-suction, horizontal configuration.
  • MZA models use casing-foot support (OH1); MZE models use centerline casing support (OH2).
  • Floating impeller design: most axial thrust is balanced hydraulically, with the remainder carried by a flat thrust bearing.
  • SKF bearings have a stated design service life of approximately 25,000 hours.
  • Multi-fin, oil-bath-lubricated bearing housing: helps improve heat dissipation and support bearing service life.
  • Interfaces are reserved for temperature and liquid-leakage probes; dry-run protection and overload-power protection devices can be selected according to the configuration.

Modular and axial-thrust design

  • 01 The pump uses a modular design with relatively good component commonality and interchangeability; hydraulic components are checked against a reference model and optimized with three-dimensional simulation.
  • 02 The casing, impeller and cover use investment casting by the silica-sol process. The isolation sleeve is approximately 1.5 mm thick, high-frequency welded and considered according to ASME VIII pressure-vessel design principles.
  • 03 An automatic axial-thrust balancing device adjusts axial clearance so the rotor floats in operation and bearing loading is improved.

Pump wetted-part materials

Material configuration
01 Wetted partsCasing, impeller, cover, shaft sleeve, shaft and inner-magnet support are made of metal or alloy selected for the medium.
02 Pump shaft07Cr15Ni7Mo2Al, 022Cr17Ni12Mo2Ti, 40Cr, 2Cr13 or Hastelloy C.
03 Isolation sleeveHastelloy C or titanium alloy.
04 Shaft sleeve, bearing and wear ringTungsten-carbide WT or pressureless-sintered silicon-carbide SSC.
05 Magnetic materialSamarium-cobalt Sm2Co17, maximum temperature 350 °C; neodymium-iron-boron NdFe2Fe14B, maximum temperature 120 °C.

A material option does not guarantee compatibility with a specific medium. Magnetic-material maximum temperatures are material conditions, not assurance that the complete pump can operate without further qualification at those temperatures.

Selection and Ordering Inputs

MZA and MZE pumps are selected according to medium properties, installation conditions and required performance. Before ordering, provide the following operating parameters so that wetted-part materials, model configuration and accessories can be confirmed.

  • Medium name and specific gravity;
  • Presence, content, particle size and hardness of solids;
  • Medium viscosity;
  • Working environment and temperature;
  • Medium composition and concentration;
  • Required flow and head;
  • NPSH available at the installation.

The pump structure can be reviewed for special operating conditions; installation dimensions are provided with the order drawings.

Operating Boundaries

Installation, operation and maintenance should follow the product manual and supplied technical documentation. Confirm the following boundaries during selection and use:

  • Do not run the pump dry. Follow the manual for start-up with the discharge valve closed and for the permitted operating time; operation with the discharge valve closed must not exceed 1 minute.
  • Before start-up, confirm that the rotation direction matches the pump rotation mark; viewed from the motor fan end, rotation should be clockwise. Reverse rotation will damage the pump.
  • If cavitation occurs, or if the inner and outer magnetic rotors are not properly coupled during operation, stop the pump within 1 minute as required by the manual.
  • Do not operate the pump with gas mixed into the medium.
  • Frequent starts and stops reduce durability; do not exceed six start/stop cycles per hour.
  • Maintain at least the specified minimum flow to avoid damage to the shaft sleeve, bearings and other components caused by insufficient lubrication and cooling.
  • Discharge pressure must not exceed the pressure limit stated in the manual for the selected model; flow must remain within the range stated in the manual and performance data sheet.
  • Confirm the medium temperature during start-up, shutdown and operation, together with the required cooling or insulation configuration, for the specific model and supplied technical documentation.

Product information

Model designationMZA and MZE Magnetic-Drive Petrochemical Process Pumps
Catalog categoryMetal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Should metal magnetic-drive pump selection start with a model or the duty?

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.