Products

FIM-G High-Temperature, Vacuum-Service Magnetic-Drive Centrifugal Pump

Home > Products > FIM-G High-Temperature, Vacuum-Service Magnetic-Drive Centrifugal Pump

FIM-G High-Temperature, Vacuum-Service Magnetic-Drive Centrifugal Pump

Product inquiry: 0523-84832479

Product introduction

The FIM-G high-temperature vacuum-service magnetic-drive centrifugal pump combines an annular-flow volute, an open impeller and an inlet inducer for media transfer in high-temperature vaporization-prone, low-temperature crystallization-prone and high-vacuum duties.

The inlet can operate under negative pressure and a heating/cooling assembly is provided. Confirm materials, sealing and operating limits for the specific medium and selected configuration.

Product presentation

FIM-G high-temperature vacuum-service magnetic-drive centrifugal pump

FIM-G high-temperature vacuum-service magnetic-drive centrifugal pump blue brand visual, showing the Jiangsu Wuxin Pump Industry Co., Ltd. name, thirty-years focused-on-chemical-pumps slogan, FIM negative-pressure magnetic-drive pump model lettering, WUXIN PUMP mark, complete pump, yellow coupling guard, green motor and base.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These capability labels summarize the series; suitability depends on the selected model and duty.

Model identification (series example; confirm the ordered specification during selection)

FIM50-10-30-G

FIM
Negative-pressure magnetic-drive pump series code
50
Pump inlet diameter, in mm
-10
Flow, in m³/h; example value
-30
Head, in m; example value
-G
High-temperature design code

FIM-G pump assembly and material visual

Single-stage, single-suction horizontal design with an annular-flow volute and an open impeller.

An inducer at the inlet improves cavitation performance; the inlet can form a negative pressure to support transfer of hot, easily vaporized media.

FIM-G pump assembly and material visual

Complete FIM-G high-temperature vacuum-service magnetic-drive centrifugal pump assembly, showing the inlet, casing, yellow coupling guard, green motor, white base, and pale-blue background.

Structural details

The material, construction and cooling features are summarized below; confirm their applicability for the selected configuration.

Materials, construction and cooling features

  • Selected materials can include 304, 316L, Hastelloy C and titanium alloy according to the duty; material compatibility must be confirmed for the specific medium and configuration.
  • The pump is single-stage, single-suction and horizontal, with an annular-flow volute and an open impeller.
  • The high mechanical strength of the casing and components supports dimensional stability; confirm the specific pressure rating and duty for the selected model.
  • The inlet inducer improves cavitation performance; a negative pressure at the inlet supports transfer of hot, easily vaporized media.
  • The heating/cooling assembly can use an external supply of hot water, steam, heat-transfer oil or chilled water to heat or cool high-temperature vaporization-prone or low-temperature crystallization-prone media.
  • An air-cooling arrangement between the outer magnetic rotor and bearing-housing bracket helps limit temperature rise in the housing and rolling bearings when conveying hot media.

Product information

Product information
Product nameFIM-G high-temperature vacuum-service magnetic-drive centrifugal pump
Product modelFIM-G
BrandJiangsu Wuxin Pump Industry Co., Ltd.
DimensionsCustomized to requirements
Place of originJingjiang, Jiangsu

These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.

Performance ranges

FIM-G series performance ranges
Suction openingDN25~DN125 mm
Flow1.5~220 m³/h
Head4~50 m
Pressure rating1.6 MPa
Speed1450/2900 r/min
Power0.55~110 kW
Maximum operating temperature350 °C

These are series ranges, not a guarantee that one pump reaches every upper limit at the same time. Confirm the performance curve, pressure, temperature and configuration for the selected model.

Application range

For chemical, pharmaceutical, pesticide, dye, electronics and semiconductor applications, handling flammable, explosive, volatile, highly toxic, corrosive (including strongly corrosive) and high-value media.

High-temperature vaporization-prone, low-temperature crystallization-prone and high-vacuum duties require selection confirmation. Confirm medium, materials, sealing and operating conditions for the actual application.

Working conditions

FIM-G working conditions
Flow range1.5~220 m³/h
Head range4~50 m
Pressure rating1.6 MPa
Speed1450/2900 r/min
Maximum operating temperature350 °C

These are series working ranges. High-pressure, high-temperature, high-vacuum and vaporization- or crystallization-prone duties require separate selection confirmation.

FIM-G working-condition pump assembly

Complete FIM-G high-temperature vacuum-service magnetic-drive centrifugal pump assembly in its working position, showing the inlet, casing, yellow coupling guard, green motor, white base and blue working-condition background.

Structural design features

  • Single-stage, single-suction horizontal design with an annular-flow volute and an open impeller.
  • An inducer at the inlet improves cavitation performance. The inlet can form a vacuum to support transfer of hot, easily vaporized media.
  • A heating and cooling assembly can use an external supply of hot water, steam, heat-transfer oil or chilled water to heat or cool hot, easily vaporized or cold, crystallization-prone media.
  • An air-cooling arrangement between the outer magnetic rotor and bearing-housing bracket helps limit temperature rise in the housing and rolling bearings when conveying hot media.

Multi-angle view 1: pump end and base

FIM-G magnetic-drive centrifugal pump front view, showing the inlet, casing, yellow coupling guard, green motor, white base and view badge.

Multi-angle view 2: magnetic drive and motor connection

FIM-G magnetic-drive centrifugal pump oblique view, showing the magnetic drive, coupling guard, green motor, white base and view badge.

Multi-angle view 3: complete oblique view

FIM-G magnetic-drive centrifugal pump high-angle oblique view, showing the casing, coupling guard, green motor, white base and view badge.

Product information

Model designationFIM-G High-Temperature, Vacuum-Service Magnetic-Drive Centrifugal Pump
Catalog categoryMetal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Should metal magnetic-drive pump selection start with a model or the duty?

Start with the duty. Define medium, temperature, flow, head, pressure, NPSH, solids and installation before screening models by curves and design.

Do not reuse alloy grades, temperature/pressure values or curves from a similar series. Duplicate model candidates are excluded from definitive recommendations until resolved.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.