IH Chemical Centrifugal Pump
Product inquiry: 0523-84832479Product introduction
The IH chemical pump is a single-stage, single-suction cantilever centrifugal pump. Its designation, rated performance point and dimensions follow ISO 2858-1975 (E). It is an energy-efficient replacement for F-type corrosion-resistant pumps and is intended for corrosive liquids with viscosity similar to water in chemical processes.
Product presentation

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
Confirm the final parameters, construction and materials for the selected model against the supplied technical documentation.
Product overview
Wetted-part materials are selected according to medium type, concentration and temperature. The IH series range is 6.3~400 m³/h flow and 5~125 m head.
The normal medium temperature is -20~105 ℃; with suitable cooling measures the conveyed medium may be hotter.
Details and construction
- 01 Selected materials*: 0Cr18Ni9, 1Cr18Ni9Ti, Cr18Ni12Mo2–3 and Cr18Ni18Mo2Cu2Ti, among others.
- 02 Easy dismantling*: the extended coupling design simplifies maintenance.
- 03 High mechanical strength*: combines stiffness comparable to a metal pump with resistance to various chemical media.
Complete pump

Performance parameters
| Performance parameters | |
|---|---|
| Flow range | 6.3~400 m³/h |
| Head range | 5~125m |
| Maximum working pressure | 1.6MPa |
| Normal working temperature | -20~105 ℃ |
| Extended temperature with cooling | -80~180 ℃ |
| Temperature note | With suitable cooling measures, the conveyed medium may be hotter |
The normal working range is -20~105 ℃; with suitable cooling, operation can extend to -80~180 ℃. Confirm the applicable range for the selected model and cooling arrangement.
Construction and application boundaries
- The IH chemical pump is a single-stage, single-suction cantilever centrifugal pump with a foot-mounted casing that can be fixed to a baseplate.
- The casing cover is located in the intermediate bracket by a spigot; the casing-to-bracket spigot joint clamps the cover between them.
- The casing has axial suction and radial discharge. The bearing frame is located in the intermediate bracket and supported on the baseplate by a frame bracket.
- An extended coupling is used. Maintenance normally does not require removal of the suction and discharge piping, casing or motor; the spacer can be removed to withdraw the rotor assembly.
- In addition to the standard shaft seal, other arrangements with ISO 3069 seal-chamber dimensions may be selected, including bellows mechanical seals and auxiliary-impeller (dynamic) seals.
Main applications
For petroleum, chemical, metallurgical, power, papermaking, food, pharmaceutical and environmental-protection plants handling corrosive liquids that contain no solid particles and have viscosity similar to water.
- Petroleum, chemical and metallurgical plants
- Power generation, papermaking and environmental protection
- Food and pharmaceutical production
- Materials selected for medium type, concentration and temperature
Confirm wetted-part materials and the final application range against medium composition, concentration, temperature and the selected model.
Working conditions
| Working conditions | |
|---|---|
| Normal working temperature | -20~105 ℃ |
| Extended temperature with cooling | -80~180 ℃ |
| Temperature condition | With suitable cooling measures, the conveyed medium may be hotter |
| Maximum working pressure | 1.6MPa |
| Higher working pressure | Available on request |
The extended temperature range requires the appropriate cooling arrangement. Confirm pressure, temperature and configuration for the selected model.
Dismantling and maintenance

Design notes
- 01 Pump construction: single-stage, single-suction cantilever; designation, rated performance point and dimensions follow ISO 2858-1975 (E).
- 02 Casing-cover construction: the cover is located in the intermediate bracket by a spigot, then clamped between the casing and bracket by their spigot connection.
- 03 Bearing-frame design: the frame is located in the intermediate bracket by a spigot and supported on the baseplate by a frame bracket.
Multiple views 01

Multiple views 02

Multiple views 03

Product information
| Model designation | IH Chemical Centrifugal Pump |
|---|---|
| Catalog category | Chemical Centrifugal Pump |
Related questions
How is the duty point of a chemical centrifugal pump determined?
Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.
How are wetted materials selected for a chemical centrifugal pump?
Use full composition, concentration, temperature, contaminants and cleaning phases to review casing, impeller, shaft, seal, lining and gasket materials separately.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.