CQH Chemical Centrifugal Pump
Product inquiry: 0523-84832479Product introduction
The CQH small-flow, high-head chemical process pump is a horizontal, two-stage, single-suction process pump for low-flow, high-head liquid transfer in petrochemical, chemical, metallurgical, pharmaceutical, coal-chemical and paper industries.
Product presentation
Product overview
The CQH pump is horizontal with axial suction, radial discharge and OH2 centerline support. Two low-specific-speed impellers are arranged back to back, each single-suction, so their axial forces largely cancel; the bearings carry the residual thrust. Integral impeller-and-casing flow passages reduce hydraulic loss. The low-flow, high-head design can replace multistage or high-speed pumps in some duties, with a simpler layout, fewer parts and easier maintenance.
Construction and features
- Horizontal, axial suction, radial discharge, OH2 centerline support.
- Two low-specific-speed impellers are back-to-back, each single-suction, cancelling axial thrust with the bearings carrying the residual load.
- Integral impeller and casing passages reduce hydraulic loss.
- Low flow and high head allow replacement of multistage or high-speed pumps in some duties; the simpler design has fewer parts and is easier to maintain.
- A mechanical seal selected for the duty reduces leakage.
Performance parameters
Series reference ranges
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Flow | Q | 20~120 | m³/h |
| Head | H | 60~400 | m |
| Speed | n | 1450/2900 | r/min |
| Working pressure | P | 2.5~8 | MPa |
| Working temperature | T | -80~+300 | ℃ |
Note: These are series reference ranges. Refer to the selected model and supplied technical documentation for actual parameters.
Applications
The series is suitable for liquid transfer in the following industries:
It handles clean liquids or liquids containing a small amount of solid particles.
- Petrochemical
- Chemical
- Metallurgy
- Pharmaceutical
- Coal chemical
- Paper
Design and selection boundaries
Confirm the following boundaries against the actual duty during selection and use:
- The pump can be compared with multistage or high-speed pumps for low-flow, high-head duties; the final selection is subject to the technical agreement.
- Performance parameters are series ranges. Confirm the actual flow, head, operating point, materials and seal configuration against the selected model and supplied technical documentation.
- Two low-specific-speed impellers are arranged back to back, each single-suction. The pump uses a two-stage, single-suction construction and is not a double-suction or ordinary single-stage pump.
- The 2.5~8 MPa and -80 to +300 °C values are series parameter ranges. Confirm the permitted pressure-temperature combination for the specific model and duty.
- Replacement of multistage or high-speed pumps applies to selected low-flow, high-head duties, subject to the technical agreement and selected model.
Confirm final parameters and construction against the selected model and supplied technical documentation.
Product information
| Model designation | CQH Chemical Centrifugal Pump |
|---|---|
| Catalog category | Chemical Centrifugal Pump |
Related questions
How is the duty point of a chemical centrifugal pump determined?
Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.
How are wetted materials selected for a chemical centrifugal pump?
Use full composition, concentration, temperature, contaminants and cleaning phases to review casing, impeller, shaft, seal, lining and gasket materials separately.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.