Product introduction

The CZ standard chemical process pump is a single-stage, single-suction, horizontal pump with dimensions to ISO 2858 (GB/T 5662) and technical conditions to GB/T 5656 (ISO 5199), serving petrochemical, refining, paper and sugar process duties.

Product presentation

Product overview

The CZ standard chemical process pump is single-stage, single-suction and horizontal, with axial suction and radial discharge. Dimensions conform to ISO 2858 (GB/T 5662) and technical conditions to GB/T 5656 (ISO 5199). It handles low- or high-temperature, neutral or corrosive liquids, with no solid particles or only a small amount, in petrochemical, refining, chemical, pulp and paper, and sugar processes.

Construction and features

  • Single-stage, single-suction, horizontal construction with axial suction and radial discharge.
  • A rear auxiliary impeller reduces seal-chamber pressure and leakage during operation, with the packed gland taking over at standstill.
  • Balance holes and front and rear wear rings reduce axial thrust, with residual thrust carried by the bearings.
  • Shaft sealing may use mechanical or packed seals selected for the duty; hazardous media require double mechanical or tandem seals.
  • Clockwise rotation when viewed from the motor end.

Performance parameters

Series reference ranges

CZ performance parameter ranges
ParameterSymbolValueUnit
Outlet diameterDN32~300mm
FlowQup to 2000m³/h
HeadHup to 160m
Speedn1450/2900, 1750/3500r/min
Working pressurePup to 2.5MPa
Working temperatureT-80~+300℃
Design standard—Dimensions: ISO 2858 / GB/T 5662; Technical conditions: GB/T 5656 / ISO 5199—

Note: ISO 2858 (GB/T 5662) addresses the dimensional system and GB/T 5656 (ISO 5199) the technical conditions; they must not be combined into a certification claim. Refer to the selected model and supplied technical documentation for actual parameters.

Applications

The series is suitable for process transfer in the following industries:

  • Petrochemical
  • Refining
  • Chemical industry
  • Pulp and paper
  • Sugar processing

Design and selection boundaries

Confirm the following boundaries against the actual duty during selection and use:

  • ISO 2858 (GB/T 5662) defines the dimensional system, while GB/T 5656 (ISO 5199) defines the technical conditions. Check them separately; do not combine them into a certification or claim of full compliance.
  • The series includes two speed ranges, 1450/2900 r/min and 1750/3500 r/min. Confirm the applicable model, operating point, materials and seal configuration against the supplied technical documentation.
  • Hazardous media require double mechanical or tandem seals. Confirm the seal arrangement, flush/cooling system and materials for the actual medium and duty.

Confirm final parameters and construction against the selected model and supplied technical documentation.

Product information

Model designationCZ Chemical Centrifugal Pump
Catalog categoryChemical Centrifugal Pump

Related questions

How is the duty point of a chemical centrifugal pump determined?

Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.

Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.

How are wetted materials selected for a chemical centrifugal pump?

Use full composition, concentration, temperature, contaminants and cleaning phases to review casing, impeller, shaft, seal, lining and gasket materials separately.

Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.