Product introduction

The HJ alkali pump is a single-stage, single-suction horizontal centrifugal pump for alkali production, non-ferrous metallurgy, steel, acid production, petrochemicals, paper, fertilizer, pharmaceutical and environmental duties. It handles crystallizing or solids-bearing alkaline liquids and similar media.

Product presentation

Product overview

The HJ pump is single-stage, single-suction, horizontal, foot-mounted, with axial suction and radial discharge. It serves alkali, metallurgy, steel, acid, petrochemical, paper, fertilizer, pharmaceutical and environmental plants, handling soda ash, ammonium salts, caustic soda, electrolytes, slurries, plating solutions and pickling liquors that may crystallize or contain solids (solids content ≤50%).

Construction and features

  • Single-stage, single-suction, horizontal construction with axial suction, radial discharge and foot mounting.
  • For impeller diameters ≥200 mm, an auxiliary impeller and recirculation holes reduce axial thrust, with residual thrust carried by the bearings.
  • Shaft and bearings are sized for heavy-duty service to limit rotor deflection.
  • Casing and impeller inlet are optimized to reduce required NPSH.
  • Mechanical or packed seals are selected with appropriate flush and cooling arrangements.
  • Front and rear axial clearances can be adjusted without removing the casing and impeller, reducing maintenance work.
  • The series can also handle crystallizing or solids-bearing media with solids content below 50% by weight.
  • Viewed from the motor end, rotation is clockwise.

Performance parameters

Series reference ranges

HJ performance parameter ranges
ParameterSymbolValueUnit
Outlet diameterDN32~200mm
FlowQ3.2~460m³/h
HeadH3.5~125m
Speedn1450/2900r/min
Working pressurePup to 1.6MPa
Working temperatureT-20~+220℃
Design standard—ISO 2858 / GB/T 5662; GB/T 5656 / ISO 5199—

Note: 220 °C and 1.6 MPa are series limits. Confirm the applicable solids-content limit against the medium and selected model.

Applications

The series serves the following industries and handles crystallizing or solids-bearing media:

  • Alkali production
  • Non-ferrous metallurgy
  • Steel
  • Acid production
  • Petrochemical
  • Paper
  • Fertilizer
  • Pharmaceutical
  • Environmental protection

Design and selection boundaries

Confirm the following boundaries against the actual duty during selection and use:

  • Solids content should generally be below 50% by weight. Where the actual solids content reaches 50%, confirm suitability separately against the medium and selected model.
  • Confirm suitability against the actual medium, solids content, materials, selected model and supplied technical documentation. The 220 °C and 1.6 MPa values are series limits and do not mean any solids-bearing medium is suitable at those combined limits.

Confirm final parameters and construction against the selected model and supplied technical documentation.

Product information

Model designationHJ Chemical Centrifugal Pump
Catalog categoryChemical Centrifugal Pump

Related questions

How is the duty point of a chemical centrifugal pump determined?

Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.

Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.

How are wetted materials selected for a chemical centrifugal pump?

Use full composition, concentration, temperature, contaminants and cleaning phases to review casing, impeller, shaft, seal, lining and gasket materials separately.

Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.