ZE/ZF/ZU Chemical Centrifugal Pump
Product inquiry: 0523-84832479Product introduction
The ZE, ZF and ZU petrochemical process pumps transfer process fluids in petrochemical plants, including high-temperature, crystallizing and corrosive duties.
Product presentation
Product overview
ZE, ZF and ZU petrochemical process pumps are single-stage, single-suction, horizontal pumps with axial suction and radial discharge, using centerline-mounted OH2 casings. They are designed with reference to API 610 and VDMA 24297 (light/medium duty). The casing cover has cooling or heating connections for water or steam to cool or insulate high-temperature or crystallizing media. Flange ratings match the casing design pressure, and nozzle loads comply with API 610.
Construction and features
- Closed impellers use balance holes and front and rear wear rings to reduce axial thrust, with residual thrust carried by the thrust bearing; open impellers use front and rear wear plates.
- The casing cover has cooling or heating connections for high-temperature or crystallizing media.
- Shaft sealing may use packed glands, single mechanical seals or double mechanical seals, with flush, cooling or barrier-fluid systems as required.
- Bearing housings may be uncooled, water-cooled or air-cooled, with oil-ring bath lubrication and an oil-mist lubrication interface; centerline mounting allows axial casing growth under high-temperature duty.
- Clockwise rotation when viewed from the motor end.
Performance parameters
Series reference ranges
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Outlet diameter | DN | 25~400 | mm |
| Flow | Q | up to 2600 | m³/h |
| Head | H | up to 300 | m |
| Speed | n | 1450/2900 | r/min |
| Working pressure | P | up to 10 | MPa |
| Working temperature | T | -80~+450 | ℃ |
| Design standard | — | API 610 / VDMA 24297 (light/medium duty) | — |
Note: 10 MPa and +450 °C are separate series limits. Confirm actual parameters and the permitted pressure-temperature combination against the selected model and supplied technical documentation.
Applications
The series is suitable for the following petrochemical process duties:
- Petrochemical process-fluid transfer
- High-temperature or crystallizing media
- Corrosive media with materials selected for the duty
Design and selection boundaries
Confirm the following boundaries against the actual duty during selection and use:
- The 10 MPa pressure and 450 °C temperature are separate series upper limits. Confirm the permitted pressure-temperature combination for the selected model and actual duty.
- API 610 and VDMA 24297 (light/medium duty) serve as standard design references and do not constitute certificates or claims of full compliance; confirm the applicable edition, flange rating and nozzle loads for the project.
- Casing-cover cooling or heating connections, bearing-housing cooling and shaft-seal arrangements are configured for the duty. Do not assume all listed options are present simultaneously.
Confirm final parameters and construction against the selected model and supplied technical documentation.
Product information
| Model designation | ZE/ZF/ZU Chemical Centrifugal Pump |
|---|---|
| Catalog category | Chemical Centrifugal Pump |
Related questions
How is the duty point of a chemical centrifugal pump determined?
Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.
How are wetted materials selected for a chemical centrifugal pump?
Use full composition, concentration, temperature, contaminants and cleaning phases to review casing, impeller, shaft, seal, lining and gasket materials separately.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.