MSK Non-metal Magnetic-drive Pump
Product inquiry: 0523-84832479Product introduction
The MSK non-metallic magnetic-drive chemical process pump uses a split, double-layer casing, with a return passage for the sliding bearing and shaft sleeve. Select materials and protection options for the actual medium and duty.
Product presentation

- High-temperature service
- High mechanical strength
- Long service life
- Broad application range
These four capabilities summarize series features; confirm suitability for the medium, duty and selected configuration.
Model identification (series example)
MSKF80-50-250AD
- MSK
- Non-metallic magnetic-drive chemical process pump series code
- F
- Material code: F denotes FEP (F46)
- 80
- Suction opening size, in mm
- 50
- Discharge opening size, in mm
- 250
- Nominal impeller diameter, in mm
- A
- Impeller trim example; suffixes can include A, B, C and D
- D
- Direct-coupled designation; shaft-coupled versions have no suffix

Performance parameters
| Performance parameters | |
|---|---|
| Suction opening | DN40~DN250 mm |
| Flow | 3.2~700 m³/h |
| Head | 5~125 m |
| Speed | 1450~2900 r/min |
| Power | 1.5~200 kW |
| Operating temperature | −80~200 °C |
| Pressure rating | 1.6~2.5 MPa |
These are series ranges and do not replace an individual pump curve. Confirm the model, medium, lining material, temperature, pressure and official technical documents for selection.
Equipment details and main construction
- 01 Selected material*: the pump casing has a split inner and outer double-layer construction.
- 02 Special process*: precision-cast ductile iron.
- 03 Distinctive dry-running design*: SSiC+C+K sliding bearings, plane bearing and shaft sleeve can be configured for dry-running material service, allowing the pump to run without liquid for a limited time.
Main applications and medium conditions
Suitable for strongly corrosive and strongly oxidizing media at any concentration, as well as various acids, alkalis, salts, organic solvents and chemical reagents.
The series can handle non-ferrous solid particles at up to 5 wt%, with a maximum particle size of 50 μm and particle hardness below 80 HS.
For solids-bearing media, the range also includes strongly corrosive and oxidizing media at various concentrations, together with acids, alkalis, salts and organic solvents. It allows media containing <10 wt% of non-angular soft particles up to 100 μm, such as flocculant, resin or plastic particles and crystalline salts. Media containing highly abrasive hard particles such as quartz sand are not suitable.
These two solid-particle ranges apply to different conditions and must not be combined into one guarantee. Confirm the actual duty before selection.
Working conditions
| Working conditions | |
|---|---|
| Operating temperature range | −80~200 °C; the actual range depends on the lining material and matches the performance-table temperature |
| Configuration | Customizable to requirements |
The temperature range cannot be separated from the lining material. Customizability does not mean that every material combination has been validated; confirm the final configuration for the selected model.

Materials, construction and design notes
- The casing uses a split inner and outer double-layer construction. The inner casing wall is 8~12 mm thick and can accommodate vacuum service; the design vacuum and allowable value depend on the duty. The inner casing material can be selected for the chemical medium and conditions to address severe corrosion, oxidation, high temperature, negative pressure and high pressure.
- The outer casing is a split-clamp structure precision-cast in ductile iron, helping the pump carry installation-system loads.
- The inner and outer casing sections can be replaced separately, simplifying maintenance and reducing service cost.
- The impeller, inner magnetic rotor and coupling mechanism were structurally optimized to help prevent inner-rotor reversal caused by incorrect commissioning or shutdown handling and to reduce the risk of impeller-to-shaft loosening and related damage. Disassembly is easier and operation is stable.
- The sliding bearing and shaft sleeve are key components. A silicon-carbide sleeve with a closed return hole is statically sealed between the impeller and inner-rotor axial space, helping internal circulating lubricant return quickly from the isolation sleeve through the impeller return hole.
- A split axial sliding bearing and a radial plane bearing with locating feet help reduce bearing damage during duty fluctuations and uneven load distribution.
- The dry-running design can use SSiC+C+K sliding bearings, plane bearing and shaft sleeve. With the corresponding materials and confirmation, short-term operation without liquid or under no-load conditions is possible; the allowed duration depends on manufacturer specifications and test data. An intelligent magnetic-pump no-load and overload power protector can provide protection in those conditions.
- The double-layer non-metallic isolation sleeve has a design pressure of 2.0 MPa, low magnetic eddy-current loss and little effect on efficiency. The conveyed-medium temperature can reach 200 °C.
- The back-pullout design allows internal inspection and parts replacement without dismantling the piping. Pulling back the bearing-frame assembly can reduce residual-liquid spillage for safer, more environmentally responsible maintenance.
- Performance parameters and outline installation dimensions are designed and manufactured according to ISO 2858 (GB/T 5662), ISO 5199 (GB/T 5656) and ISO 15783 (GB/T 25140).
- Interfaces are provided for the sliding bearing, process fluid, monitoring measurements and sensors. The sensor contact end directly contacts the heat-dissipation point for more accurate measurement and monitoring.
Model and selection boundaries
MSK is the series code for the non-metallic magnetic-drive chemical process pump.
MSK F 80-50-250 A D explains the code structure only. A is an impeller trim example, D denotes direct-coupled and shaft-coupled versions carry no suffix. Confirm the order code, openings, impeller diameter and configuration separately.
The 2.0 MPa figure is the design pressure of the double-layer non-metallic isolation sleeve. The 1.6~2.5 MPa range is the series pressure rating. They describe different structures and must not be combined or substituted for each other.
The two solid-particle ranges apply to different conditions and must not be used to overrule one another. Selection must use the actual duty and official technical documents.
Performance values are series data and do not replace an individual pump curve, bill of materials or order specification. Temperature is also limited by the lining material, and dry-running materials and protection devices must be specified in the order configuration.
Product information
| Model designation | MSK Non-metal Magnetic-drive Pump |
|---|---|
| Catalog category | Non-metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.