IMCH Fluoroplastic-lined Magnetic-drive Pump
Product inquiry: 0523-84832479Product introduction
The IMCH fluoroplastic-lined magnetic-drive pump uses a double-layer split casing and rear-pull maintenance design. Confirm the coupling form against the selected model and ordered configuration.
Product presentation

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These four capabilities summarize series features; confirm suitability for the medium, temperature, pressure and selected configuration.
Model identification (series example)
IMCH65-40-200FSSKD
- IM
- International-standard magnetic-pump series code
- C
- Fluoroplastic-lined construction code
- H
- Rear-pull safety/environmental construction code
- 65
- Suction opening size, in mm
- 40
- Discharge opening size, in mm
- 200
- Nominal impeller diameter, in mm
- F
- Wetted-part material code; F denotes FEP (F46)
- SS
- Shaft-sleeve, sliding-bearing and dynamic/static-ring material code
- K
- Seal-ring material code
- D / L
- D denotes direct-coupled and L shaft-coupled; these are final model options, not fixed suffixes

Performance parameters
| Performance parameters | |
|---|---|
| Suction opening | DN25~DN200 mm |
| Flow | 1.6~400 m³/h |
| Head | 5~125 m |
| Speed | 1450~2900 r/min |
| Power | 1.5~200 kW |
| Operating temperature | −80~150 °C |
| Pressure rating | 1.6 MPa |
These are series ranges, not an individual duty point. The 1.6 MPa in the performance table is the pump-body pressure rating; the outer isolation sleeve also lists 1.6 MPa absolute pressure. The equal values describe different structures.
Equipment details and main construction
- 01 Selected materials: resistance to strong corrosion, oxidation, high and low temperatures and pressure; confirm medium limits against the selected liner and wetted materials.
- 02 Special process: the casing is precision-cast in ductile iron, then high-temperature molding and sintering tightly bond the fluoroplastic liner to the volute wall.
- 03 Rear-pull safety and maintenance: for easier servicing, internal inspection can be performed without removing piping, and the withdrawn assembly can reduce residual-liquid spillage.
Main applications and conditions
Suitable for clean liquids of any concentration that are strongly corrosive or strongly oxidizing, including acids, alkalis, salt solutions, organic solvents and chemical reagents.
Suitable for chemical, pharmaceutical, environmental-protection and metallurgy industries. Confirm medium compatibility, concentration, temperature, pressure and cleanliness against the selected liner and wetted materials; an industry name alone is not a suitability guarantee.
Working conditions
| Working conditions | |
|---|---|
| Operating temperature range | −80~150 °C (depending on liner material) |
| Configuration | Customizable to requirements |
The temperature range depends on the liner material; it is not a universal guarantee for every medium or individual pump. Customizability also does not mean every material combination has been validated.

Materials, construction and design notes
- The casing uses a split, double-layer construction. The inner casing wall is 8~12 mm thick, and its material can be selected for the chemical medium and duty. Static-vacuum protection is listed to 0 Pa; confirm the applicable conditions for the selected model.
- The outer shell uses a vertically split half-clamp construction and can be fitted with drain, valve, temperature-sensor and leakage-alarm provisions; inspection does not require removing the piping.
- The casing is precision-cast in ductile iron. Processing plus high-temperature molding and sintering tightly bond the fluoroplastic liner to the volute wall. The liner normally does not detach or delaminate within −80~150 °C; the metal casing retains mechanical strength while wetted parts provide strong corrosion, oxidation, high/low-temperature and pressure resistance.
- The pump cover (isolation plate) uses an angled three-in/one-out guide-hole construction, with a metal insert framework and a fluoroplastic outer molding sintered at high temperature to circulate lubricating liquid in the bearing cavity.
- The double non-metallic FEP/PFA isolation sleeve uses an outer sleeve with an absolute pressure of 1.6 MPa and produces no magnetic eddy current, helping reduce eddy-current loss and energy use. Medium temperature can reach 150 °C. This is an isolation-sleeve construction value, not the pump-body rating in the performance table.
- The inner magnetic rotor and shaft use an integrated, fluoroplastic-covered construction to increase assembly stiffness. Samarium-cobalt permanent magnets provide stable magnetic performance and high torque transmission within the applicable temperature range.
- The closed impeller uses optimized flow passages for high efficiency and low net positive suction head. It contains a large alloy-steel insert and is threaded to the inner magnetic rotor. Operation must follow the specified direction; reverse rotation is prohibited.
- The shaft sleeve, sliding bearing and dynamic/static rings can use SiC, SSiC or SSiC+C+K; SSiC+C+K can tolerate brief loss-of-liquid dry running. Confirm the material against the medium, temperature and selected configuration.
- The rear-pull construction permits internal inspection and part replacement without removing piping. The integrated suspension and bearing housing uses larger front and smaller rear rolling bearings; this feature applies only to the direct-coupled construction.
- The bearings are grease-lubricated and the housing has an oil-storage structure. About 3,000 cumulative operating hours under normal conditions can be achieved before re-greasing; actual maintenance depends on speed, temperature, load and operating state.
- Product performance and outline dimensions comply with ISO 2858 (GB/T 5662), ISO 5199 (GB/T 5656) and ISO 15783 (GB/T 25140). Selection still requires the selected model, dimension sheet and official technical documents.
Model and selection boundaries
The catalog model is IMCH without a fixed coupling suffix. The model example is IMCH 65 -40 -200 F SS K D.
The final D in the model example denotes the direct-coupled option. D and L denote direct-coupled and shaft-coupled respectively; do not turn either into a fixed suffix or infer that the series has only one coupling form.
The 1.6 MPa in the performance table is the pump-body pressure rating. The outer isolation sleeve also lists 1.6 MPa absolute pressure. The equal values apply to different structures and conditions and cannot substitute for each other.
Performance, temperature and construction values are series ranges or specific structural conditions. Final selection must confirm medium, liner, temperature, pressure, pump curve, installation dimensions and official technical documents.
Product overview
IMCH Fluoroplastic-lined Magnetic-drive Pump
The IMCH magnetic-drive pump uses fluoroplastic wetted parts. The casing and fluoroplastic are combined by high-temperature sintering and molding, with a magnetic drive and double-layer containment shell.
The manual states that slurry is generally not conveyable. With WX PLUS bearings, slurry concentration must not exceed 5 wt%, particle hardness must be below 80 Hs and particle size below 50 μm. Changes in liquid specific gravity and viscosity affect shaft power, output pressure and head. The stated pump temperature ranges are -60°C to 100°C for FEP and -60°C to 160°C for PFA.
Technical parameters
| Pump type | Fluoroplastic-lined magnetic-drive pump |
|---|---|
| Casing and lining | Ductile-iron casing with fluoroplastic liningNote · Confirm exact grades from order documents |
| Containment shell | Described as a double-layer design in the manualNote · Confirm materials, pressure boundary and document revision for the configuration |
| Bearing and sleeve options | SSiC and WX PLUSNote · A material capability does not permit routine dry running |
| Impeller | Closed fluoroplastic-alloy impellerNote · Exact material and form depend on duty |
Selection guidance
- Medium name, composition, concentration, density and viscosity
- Normal, minimum and maximum medium temperature
- Required flow, head, system pressure and available NPSH
- Solids content, particle size and hardness, and crystallization tendency
- Installation arrangement, ambient conditions, power supply and protection requirements
Operating notes
- Do not treat the limits of a series range as one duty point available from every size.
- Compatibility with wetted, bearing, seal or containment materials must be reviewed for the actual medium and duty.
- Start-up, shutdown, valve operation and maintenance must follow the latest manual for the exact model.
- Patent numbers are retained as historical fields from the document revision; current legal status should be checked against valid certificates and official registers.
- Selection requires solids content, particle size and hardness, viscosity, temperature, flow, head and available NPSH.
- A short-duration material tolerance must not be interpreted as permission for continuous dry running.
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.