Product introduction

The MDZ-L fluoroplastic-lined magnetic-drive self-priming pump is the shaft-coupled version, intended for lifting and transferring media from low liquid levels in tanks and vessels. Confirm self-priming height, materials and installation details for the selected model and site.

Product presentation

MDZ fluoroplastic-lined magnetic-drive self-priming pump

MDZ-D fluoroplastic-lined magnetic-drive self-priming pump with the pump, motor and base against a deep-blue brand background. MDZ-L / MDZ-L
  • High-temperature service
  • High mechanical strength
  • Long service life
  • Broad application range

The four benefits summarize temperature resistance, mechanical strength, service life and application range. No single benefit guarantees suitability for a specific medium, temperature, pressure or pump configuration; confirm suitability during selection.

Model identification and suffix guide

MDZ65-40-200L/D/T

MDZ
Fluoroplastic-lined magnetic-drive self-priming pump series
65
Suction opening size, in mm
-40
Discharge opening size, in mm
-200
Nominal impeller diameter, in mm
L/D/T
L shaft-coupled, D direct-coupled, T bracket-mounted

Pump construction and equipment features

Oblique MDZ magnetic-drive self-priming pump illustration showing the suction end, casing, motor, mounting base and three technical notes. MDZ-L

Performance parameters

MDZ series ranges (confirm individual pump data during selection)
MDZ series ranges (confirm individual pump data during selection)Value
Suction openingDN40~DN125 mm
Flow3~180 m³/h
Head5~50 m
Speed1450/2900 r/min
Power3~55 kW
Operating temperature−40~100 °C (depending on liner material)
Pressure rating1.6 MPa
Vertical self-priming height3.5~6.5 m within 180 s and the specified installation conditions

These are MDZ series ranges, not a duty point or guarantee for one pump. The 3.5~6.5 m self-priming height depends on the 180 s limit, installation conditions and liner material and is not achievable in every installation. Operating temperature also depends on the liner material.

Equipment details and construction features

  • 01 Selected materials: the wetted parts resist strong corrosion and oxidation and are suitable for high and low temperatures and pressure. Confirm medium, temperature and pressure suitability against the selected liner and configuration.
  • 02 Special process: the pump body is precision-cast in ductile iron, with fluoroplastic lining on the key wetted surfaces for the combined mechanical strength of metal and corrosion resistance.
  • 03 Double-start threaded shaft-sleeve guide grooves: these promote axial flow in the pump chamber during self-priming and help reduce the temperature rise of the sliding bearing and shaft sleeve. Confirm the shaft-sleeve material and fit for the selected configuration.
  • 04 Self-priming performance: under the specified installation and medium conditions, the pump can reach a vertical self-priming height of 3.5~6.5 m within 180 s. The actual value varies with model, liner material and site conditions.

Main applications

Suitable for strongly corrosive and strongly oxidizing liquids such as acids, alkalis, salt solutions, organic solvents and chemical reagents. Confirm concentration and compatibility against the selected liner and wetted materials.

Suitable for low-level lifting and transfer from tanks, vessels and reactors. Confirm compatibility, concentration, temperature and configuration against the selected model and wetted materials.

Working conditions

Recommended working conditions (confirm against liner material and installation)
Recommended working conditions (confirm against liner material and installation)Value
Operating temperature range−40~100 °C
Temperature limitDepending on liner material
ConfigurationCustomizable to the duty
Self-priming height3.5~6.5 m within 180 s and the specified installation conditions

The operating temperature range depends on the liner material. A customized configuration still requires confirmation of medium compatibility, installation and self-priming conditions. The 180 s limit and 3.5~6.5 m height apply only under their stated performance prerequisites.

MDZ self-priming pump in service

MDZ magnetic-drive self-priming pump in a working installation, with the pump body, suction end and motor mounted on a base or bracket. MDZ-L

Materials, construction and design notes

  • The pump body is precision-cast in ductile iron. Multiple machining steps and high-temperature sintering and molding firmly anchor the fluoroplastic lining to the metal body. Under static vacuum or alternating high and low medium temperatures, the lining resists separation, cracking and blistering while the metal body maintains mechanical strength, corrosion and vacuum resistance and broad temperature adaptability.
  • A fluororubber check flap is fitted between the suction inlet and the front pump cover. It provides reliable sealing, a long service life and helps prevent medium backflow during shutdown. Actual life still depends on the medium and operating conditions.
  • The mating surface between the front cover and pump body receives special machining, so no gasket is required to assist sealing. The joint must still be used in accordance with the specified interface dimensions and assembly requirements, which take precedence over general design notes.
  • The shaft sleeve has double-start threaded guide grooves that promote axial flow in the pump chamber during self-priming and help reduce the temperature rise of the sliding bearing and shaft sleeve.
  • The MDZ-L version uses a shaft-coupled construction for installations that require a separate coupling between the motor and pump shaft. This arrangement differs from the MDZ-D direct-coupled and MDZ-T bracket-mounted versions, whose dedicated mounting features do not apply to this model.
  • The MDZ series offers MDZ-L, MDZ-D and MDZ-T construction forms for selection according to site installation and duty. The MDZ-D can also be mounted on a mobile trolley; that configuration applies only to the corresponding model.
  • Under the specified conditions, the vertical self-priming height can reach 3.5~6.5 m within 180 s. Confirm installation conditions, medium characteristics and liner material together during selection.
  • Suitable for strongly corrosive and strongly oxidizing media, including acids, alkalis, salt solutions, organic solvents and chemical reagents, for low-level lifting and transfer from tanks, vessels and reactors. Confirm compatibility against the actual materials and duty.

Model identification and selection boundaries

In the MDZ-L designation, L denotes a shaft-coupled construction. The model example MDZ 65 -40 -200 L/D/T explains all three coupling forms: L for shaft-coupled, D for direct-coupled and T for bracket-mounted. This model is shaft-coupled; confirm the supplied construction and installation dimensions.

The dimensions and suffixes in the model example MDZ 65 -40 -200 L/D/T explain the naming convention. Confirm the actual model and suffix during selection; the handbook example is not an order code.

Confirm series performance, temperature, self-priming height, materials and construction against the selected model and suffix, liner material, medium compatibility, temperature, pressure, installation, self-priming time and actual duty, with reference to the formal technical documents.

Product information

Model designationMDZ-L Non-metal Magnetic-drive Pump
Catalog categoryNon-metal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.