CQF-N Non-metal Magnetic-drive Pump
Product inquiry: 0523-84832479Product introduction
The CQF-N fluoroplastic-alloy magnetic-drive pump is the fixed-shaft identity and uses non-metallic wetted materials. Confirm the material and operating conditions against the medium and ordered configuration.
Product presentation
CQF-N fluoroplastic-alloy magnetic-drive pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability highlights summarize the product construction; confirm performance and configuration in the selected model documentation.
Model identification (code example)
CQF65-50-125NS
- CQ
- Small magnetic-drive pump series code
- F
- Non-metallic material code
- 65 / 50
- Suction/discharge opening sizes, in mm
- 125
- Nominal impeller diameter, in mm
- A / N
- A denotes dynamic-shaft; N denotes fixed-shaft. The CQF-N uses the fixed-shaft form
- S
- Shaft/bearing material marker example
CQF-N pump assembly structure

Performance parameters
| Performance parameters | |
|---|---|
| Suction opening | DN20~DN65 mm |
| Flow | 0.8~25 m³/h |
| Head | 3.5~32 m |
| Speed | 1450~2900 r/min |
| Power | 0.37~5.5 kW |
| Operating temperature | −80~100 °C |
| Pressure rating | 1.6 MPa |
These are series performance ranges, not an individual pump curve or guarantee. Confirm the model, medium, material, temperature, pressure and official technical documents for selection.
Equipment details, 01/02/03 structure notes and core features
- Independently developed, distinctive construction.
- 01 Selected material*: corrosion and oxidation resistance.
- 02 Special process*: manufactured from fluoroplastic alloy.
- 03 Non-metallic double-layer isolation sleeve with a bearing seat*: intended to reduce magnetic eddy-current loss and improve efficiency; medium-transfer temperature below 100 °C.
Main applications and conditions
For small-flow, low-head duties conveying acids, alkalis and salts at various concentrations that are strongly corrosive or oxidizing, as well as non-crystallizing media containing small amounts of solids.
Confirm medium compatibility, concentration, crystallization tendency, particle characteristics and operating boundaries against the actual duty and official technical documents.
Working conditions
| Working conditions | |
|---|---|
| Operating temperature range | −80~100 °C (depending on lining material) |
| Configuration | Customizable to requirements |
| Shaft construction | The CQF-N uses the fixed-shaft form. In the model code, N denotes fixed-shaft and A denotes dynamic-shaft |
−80~100 °C is the series temperature range and the medium-transfer temperature is below 100 °C; the applicable temperature depends on the lining material. Customizability does not mean that every material combination has been validated, so confirm the final configuration for the selected model.
CQF-N pump assembly in the working-condition visual

Materials, construction and design notes
- Design notes: the construction at a glance.
- The CQF non-metallic magnetic-drive pump is a small pump and one of the early corrosion-resistant pump types, with more than thirty years of application.
- Wetted-part material options are PVDF, fluoroplastic alloy (FEP+PTFE) and reinforced polypropylene (FRPP); confirm the actual material against the medium and ordered configuration.
- The impeller and inner magnetic rotor use a splined connection that facilitates replacement of the inner rotor, torque adjustment and changes to impeller travel.
- A non-metallic double-layer isolation sleeve with a bearing seat reduces magnetic eddy-current loss and can help improve efficiency and reduce energy consumption.
- The CQF-N uses the fixed-shaft construction; confirm the materials, splined connection and double-layer isolation sleeve for the selected model.
- The medium-transfer temperature is below 100 °C. The series temperature range is −80~100 °C and depends on the lining material; confirm the applicable temperature for the selected configuration.
Model and selection notes
The CQF-N fluoroplastic-alloy magnetic-drive pump has the model example CQ F 65 -50 -125 N S, in which N denotes fixed-shaft.
In the model code, N denotes fixed-shaft and A denotes dynamic-shaft. The CQF-N uses the fixed-shaft form; confirm shaft and bearing configuration for the selected model.
Numbers in the model example explain the code structure and do not fix the equipment's opening sizes, impeller diameter or configuration.
Performance values are series ranges and do not replace an individual pump curve, bill of materials or order specification. The series temperature range is −80~100 °C, the medium-transfer temperature is below 100 °C, and the applicable temperature depends on the lining material.
Confirm medium compatibility, concentration, crystallization and solids conditions, pressure and installation method for the selected configuration.
Product information
| Model designation | CQF-N Non-metal Magnetic-drive Pump |
|---|---|
| Catalog category | Non-metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.