Products

MSW-D Non-metal Magnetic-drive Pump

Home > Products > MSW-D Non-metal Magnetic-drive Pump

MSW-D Non-metal Magnetic-drive Pump

Product inquiry: 0523-84832479

Product introduction

The MSW-D magnetic-drive non-metallic vortex pump is the direct-coupled model for media containing suspended solids, fibres or small amounts of gas. Lubrication and external circulation-flush conditions are stated separately.

Product presentation

MSW magnetic-drive vortex pump

Blue MSW magnetic-drive non-metallic vortex pump brand visual with the Jiangsu Wuxin Pump Industry Co., Ltd. name, thirty-years slogan, MSW model lettering, WUXIN PUMP mark, product subtitle, green pump body, green motor, black baseplate and blue stage.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These capability highlights summarize the product construction; confirm performance and configuration in the selected model documentation.

Model identification (code example)

MSW50-32160AD/L

MSW
Magnetic-drive non-metallic vortex pump series
50 / 32
Suction/discharge opening sizes, in mm
160
Head code example
A/B/C
Impeller trimming code
D/L
D denotes direct-coupled; L shaft-coupled

MSW pump assembly and 01/02/03 structure details

MSW magnetic-drive non-metallic vortex pump, showing the green pump body, green motor, black baseplate and the positions for 01 selected material, 02 special process and 03 internal mechanical-seal construction.

Performance parameters

Series performance ranges
Performance parameters
Suction openingDN40~DN150 mm
Flow3.2~400 m³/h
Head10~50 m
Speed960/1450 r/min
Power3~132 kW
Operating temperature−80~180 °C
Pressure rating1.6~2.5 MPa

These are series performance ranges, not an individual pump curve or guarantee. Confirm the model, medium, material, temperature, pressure, flush conditions and official technical documents for selection.

Equipment details, 01/02/03 structure notes and core features

  • Independently developed, distinctive construction.
  • 01 Selected material: good corrosion and oxidation resistance.
  • 02 Special process: the impeller is designed as a non-metallic vortex-flow impeller.
  • 03 Internally installed mechanical-seal construction: the isolation sleeve does not communicate with the pump pressure chamber; external lubrication/flush medium uses a water circuit.

Main applications and conditions

For conveying strongly corrosive or oxidizing acids, alkalis and salts that contain suspended solid particles, fibrous matter and small amounts of gas.

Confirm medium compatibility, concentration, particle characteristics, temperature, pressure, lubrication and external circulation-flush conditions against the actual duty; do not infer suitability from the series application statement alone.

Working conditions

Working conditions
Working conditions
Operating temperature range−80~180 °C (depending on lining material)
ConfigurationCustomizable to requirements

The operating temperature range depends on the lining material. Customizability does not mean that every material combination has been validated; confirm the final configuration against the selected model and official technical documents.

MSW-D pump assembly in the working-condition visual

Complete MSW-D magnetic-drive non-metallic vortex pump in an operating-condition visual, showing the green pump end, green motor, both pump feet, mounting base, blue field and light-gray floor.

Materials, construction and design notes

  • Design notes: the construction at a glance.
  • The impeller uses a non-metallic vortex-flow blade construction and is located behind the pressure chamber inside an annular cavity. During rotation, the front annular bladeless cavity forms through-flow and circulation; the lower-pressure central region helps some solids leave with the vortex, reducing clogging risk and impeller wear.
  • A solid-guiding ring between the rear of the impeller and the sliding-bearing seat blocks particles from entering the sliding-bearing area.
  • An external circulation flush port on the sliding-bearing seat provides flushing and lubrication. The medium passes through the isolation sleeve, sliding-bearing grooves and sleeve passages into the medium in the pump pressure chamber.
  • A mechanical seal inside the solid-guiding ring isolates the isolation sleeve from the pump pressure chamber; external lubrication/flush medium uses tap water.
  • Under the stated condition of tap-water circulation lubrication/flush at pressure comparable to pump outlet, the indicated flush flow is about 0.9 L/min. This value is not a universal flow guarantee for every installation.

Model and selection notes

The MSW-D magnetic-drive non-metallic vortex pump has the model example MSW 50 -32 160 A D/L; D/L describes the coupling form, and the final model must be confirmed against the ordered configuration.

Model code notes: MSW is the magnetic-drive non-metallic vortex pump series; 50/32 are suction/discharge opening sizes in mm; 160 is a head-code example; A/B/C is the impeller trimming code; D and L denote direct-coupled and shaft-coupled respectively.

Performance ranges are series data and do not replace an individual pump curve, bill of materials or order specification. Confirm model, medium, particles, temperature, pressure, flush-water conditions and installation method.

About 0.9 L/min applies to the stated tap-water circulation lubrication/flush condition at pressure comparable to pump outlet. It is not a universal flow or pressure guarantee for all installations.

D denotes direct-coupled and L denotes shaft-coupled. The series name, code example and final order model must be confirmed separately; shaft, bearing, material and flush configuration cannot be inferred from the MSW series name alone.

Product information

Model designationMSW-D Non-metal Magnetic-drive Pump
Catalog categoryNon-metal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.