Products

IMC-D Non-metal Magnetic-drive Pump

Home > Products > IMC-D Non-metal Magnetic-drive Pump

IMC-D Non-metal Magnetic-drive Pump

Product inquiry: 0523-84832479

Product introduction

The IMC-D fluoroplastic-lined magnetic-drive pump is the direct-coupled model with non-metallic wetted parts, mounted with the motor on a short base. Operating temperature and medium suitability depend on the selected materials and configuration.

Product presentation

IMC-D fluoroplastic-lined magnetic-drive pump

IMC-D fluoroplastic-lined magnetic-drive pump with a green pump assembly and motor directly coupled on a black short base.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

The four benefits summarize temperature resistance, mechanical strength, service life and application range. No single benefit guarantees suitability for a specific medium, temperature, pressure or configuration; confirm suitability during selection.

Model identification and naming

IMC F65-50-160LC/F

IM
International-standard magnetic-pump series
C
Fluoroplastic-lined construction code
F
Wetted-part material code; F is FEP (F46)
65
Suction opening, in mm
50
Discharge opening, in mm
160
Nominal impeller diameter, in mm
L/D
L shaft-coupled, D direct-coupled; no suffix bracket-mounted
C/F
Shaft-sleeve and sliding-bearing material code

IMC construction and the IMC-D arrangement

Oblique IMC series pump illustration showing the green casing, motor, mounting base and notes on materials, casting and bracket-mounted construction.

Performance parameters

IMC series ranges (confirm individual pump data during selection)
Performance parameters
Suction openingDN40~DN100 mm
Flow3.2~100 m³/h
Head8~50 m
Speed1450~2900 r/min
Power0.55~55 kW
Operating temperature−80~150 °C (depending on liner material)
Pressure rating1.6 MPa

These are IMC series ranges, not an individual pump curve or guarantee. Confirm the medium, liner material, temperature, pressure, pump curve, installation dimensions and formal technical documents for the selected configuration. The example IMC F 65 -50 -160 L C/F illustrates the naming convention. L means shaft-coupled, D means direct-coupled, and no coupling suffix means bracket-mounted. The example dimensions explain the codes only; supply follows the selected model, materials and order specification.

Equipment details and construction features

  • 01 Selected materials: the wetted parts resist strong corrosion and oxidation and are suitable for high and low temperatures and pressure. Confirm medium, temperature and pressure limits against the selected liner and configuration.
  • 02 Special process: the casing is precision-cast in ductile iron, with a liner firmly bonded to the metal body. See Design notes below for the casting, lining and construction details.
  • 03 The series illustration identifies a bracket-mounted outline for convenient installation and removal; this applies to the suffix-free IMC. IMC-D uses a direct-coupled short base with a different mounting arrangement.
  • Three core advantages, more dependable operation summarizes the materials, construction and operating reliability. See the design notes below for details; the series material description is not expanded into additional equipment claims.

Main applications and conditions

Suitable for clean liquids of any concentration that are strongly corrosive or strongly oxidizing, including acids, alkalis, salt solutions, organic solvents and chemical reagents. Confirm compatibility against the selected liner and wetted materials.

Suitable for corrosive-medium transfer in chemical, pharmaceutical, environmental-protection and metallurgy applications. Confirm medium compatibility, concentration, solids and crystallization conditions against the selected configuration; an industry name alone is not approval.

Working conditions

Recommended working conditions (confirm against liner material and selection)
Working conditions
Operating temperature−80~150 °C (depending on liner material)
Operating pressure1.6 MPa
ConfigurationCustomizable to requirements
Suitable mediaStrongly corrosive or oxidizing clean liquids; confirm against the selected liner and wetted materials
Catalog constructionIMC-D is direct-coupled to the motor and mounted on a short base. The suffix-free IMC is bracket-mounted and IMC-L is shaft-coupled; these arrangements are not interchangeable.
Performance rangeSee the IMC series performance table above

The IMC series temperature range is −80~150 °C, and the actual limit depends on the liner material. A customizable configuration does not mean every material combination has been validated; confirm the final temperature, medium and configuration for the selected model.

IMC-D pump assembly in service

IMC-D fluoroplastic-lined magnetic-drive pump in a working-condition setting, with a green direct-coupled pump and motor on a black short base.

Design notes: materials, construction and operating boundaries

  • Design notes: construction explained at a glance.
  • Pump casing: precision-cast in ductile iron, then machined and high-temperature molded to bond the fluoroplastic liner tightly to the volute wall. Within −80~150 °C, the liner normally resists separation and delamination while the metal casing maintains mechanical strength. The wetted section also resists strong corrosion and oxidation and accommodates high and low temperatures and pressure. Actual limits still depend on the liner material.
  • Inner magnetic rotor: the shaft and inner magnetic yoke use an integrated construction wrapped in fluoroplastic. This improves the stiffness of the impeller, shaft and inner-rotor assembly and helps maintain mechanical strength and reliability during high-speed operation, duty fluctuations and uneven axial and radial loading, reducing damage to the shaft sleeve and sliding bearing and the risk of shaft fracture. The permanent magnets use samarium-cobalt alloy.
  • Impeller: a closed impeller is used, with carbon-fiber-reinforced fluoroplastic alloy F50-2 available as an option. Its maximum medium temperature is 150 °C, and it offers improved wear resistance and durability. That value depends on the material configuration and does not replace confirmation of the complete pump duty.
  • IMC-D: directly coupled to the motor and mounted on a short base, providing a compact footprint, stable operation, lower noise and convenient maintenance that help reduce operating and maintenance costs.
  • IMC, IMC-D and IMC-L share the same fluoroplastic lining and magnetic-drive foundation but use different coupling and mounting arrangements. Construction notes apply to the matching model; confirm arrangements for other suffixes in the documentation for that model.

Model identification and selection boundaries

IMC-D uses a direct-coupled short-base arrangement. The model example IMC F 65 -50 -160 L C/F explains the series naming convention; its L does not describe the IMC-D supply arrangement.

Callout 03 in the series illustration describes the suffix-free IMC bracket-mounted outline and does not apply to IMC-D. The IMC-D arrangement is a direct-coupled short base, subject to the selected model and technical order documents.

IMC, IMC-D and IMC-L share the series materials and magnetic-drive technology but use different mounting arrangements. IMC-D uses the direct-coupled short base rather than the suffix-free IMC bracket or the IMC-L shaft coupling.

Model examples, equipment illustrations and the actual order code have different meanings. Dimensions and suffixes in an example only explain the naming convention and do not replace the selected model, bill of materials or technical order specification.

Callout 03 in the construction illustration describes the IMC bracket-mounted outline, which facilitates installation and removal. The suffix-free IMC uses this arrangement; IMC-D uses a direct-coupled short base and IMC-L uses a shaft-coupled bearing housing, as described for each model.

Performance values are series ranges and do not replace an individual pump curve, bill of materials or technical order specification. The F50-2 limit of 150 °C and the −80~150 °C range must be confirmed for the actual material configuration.

Confirm medium compatibility, concentration, crystallization and solids conditions, pressure, installation and flushing against the selected configuration. The four benefit labels summarize series capabilities and do not replace technical confirmation for a specific duty.

Product information

Model designationIMC-D Non-metal Magnetic-drive Pump
Catalog categoryNon-metal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.