MSW-L Non-metal Magnetic-drive Pump
Product inquiry: 0523-84832479Product introduction
The MSW-L magnetic-drive non-metallic vortex pump is a shaft-coupled model with a vortex-flow construction and an external circulation flush port.
Product presentation
MSW-L magnetic-drive non-metallic vortex pump

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability highlights summarize the product construction; confirm performance and configuration in the selected model documentation.
Model identification (code example)
MSW50-32160AD/L
- MSW
- Magnetic-drive non-metallic vortex pump series
- 50 / 32
- Suction/discharge opening sizes, in mm
- 160
- Head code example
- A/B/C
- Impeller trimming code
- D/L
- D denotes direct-coupled; L shaft-coupled
MSW pump assembly and 01/02/03 structure details

Performance parameters
| Performance parameters | |
|---|---|
| Suction opening | DN40~DN150 mm |
| Flow | 3.2~400 m³/h |
| Head | 10~50 m |
| Speed | 960/1450 r/min |
| Power | 3~132 kW |
| Operating temperature | −80~180 °C |
| Pressure rating | 1.6~2.5 MPa |
These are series performance ranges, not an individual pump curve or guarantee. Confirm the model, medium, material, temperature, pressure and official technical documents for selection.
Equipment details, 01/02/03 structure notes and core features
- Independently developed, distinctive construction.
- 01 Selected material: good corrosion and oxidation resistance.
- 02 Special process: the impeller is designed as a non-metallic vortex-flow impeller.
- 03 Internally installed mechanical-seal construction: the isolation sleeve is not connected to the pump pressure chamber; external lubrication/flush medium uses a water circuit.
Main applications and conditions
For conveying strongly corrosive or oxidizing acids, alkalis and salts that contain suspended solid particles, fibrous matter and small amounts of gas.
Confirm medium compatibility, particle characteristics, temperature, pressure, flush conditions and actual duty; do not infer suitability from the series application statement alone.
Materials, construction and design notes
- The non-metallic vortex-flow impeller is located behind the pressure chamber and within an annular cavity. Its flow path helps carry particles out with the vortex and reduce clogging risk.
- A solid-guiding ring between the rear of the impeller and the sliding-bearing seat blocks particles from entering the sliding-bearing area.
- An external circulation flush port on the sliding-bearing seat provides flushing and lubrication; the medium flows through the isolation sleeve, bearing grooves and sleeve passages.
- The isolation sleeve does not communicate with the pressure chamber, and external lubrication/flush uses a water circuit. At pressure comparable to pump discharge, the indicated flush flow is about 0.9 L/min; this value is not a universal field guarantee.
Model and selection notes
The MSW-L magnetic-drive non-metallic vortex pump has the model example MSW 50 -32 160 A D/L; D/L describes the coupling form, and the final model must be confirmed against the ordered configuration.
Model code notes: MSW is the magnetic-drive non-metallic vortex pump series; 50/32 are suction/discharge opening sizes in mm; 160 is a head-code example; A/B/C is the impeller trimming code; D and L denote direct-coupled and shaft-coupled respectively.
Performance ranges are series data and do not replace an individual pump curve, bill of materials or order specification. Confirm model, medium, particles, temperature, pressure, flush-water conditions and installation method.
The 0.9 L/min value applies to the stated flush condition and is not a universal flow guarantee for every installation. Confirm actual flush flow and pressure against the selected configuration and official technical documents.
Product information
| Model designation | MSW-L Non-metal Magnetic-drive Pump |
|---|---|
| Catalog category | Non-metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.