MKF-L Non-metal Magnetic-drive Pump
Product inquiry: 0523-84832479Product introduction
The MKF-L non-metallic magnetic-drive centrifugal pump uses a split double-layer casing, a shaft-seal-free magnetic drive and non-metallic wetted construction. The following sections cover the equipment, seven part groups, working range and selection boundaries.
Product presentation

- High-temperature service
- High mechanical strength
- Long service life
- Broad application range
These four capabilities summarize series features; confirm suitability for the medium, duty and selected configuration.
Product overview
The MKF series consists of single-stage, single-suction, horizontal non-metallic magnetic-drive chemical-process pumps with a shaft-seal-free arrangement and non-metallic wetted surfaces.
The shaft-seal-free design reduces leakage risk and seal-maintenance work. Dimensions and performance parameters reference EN 22858/ISO 2858 and JB/T 7742-2013; confirm the applicable edition and scope in the selected model's technical documents.
Direct-coupled wording in the series overview is a general example; confirm the supplied mounting arrangement for the selected model and order configuration.
Performance parameters
| Suction opening | DN40~DN80 mm |
|---|---|
| Flow | 3.2~50 m³/h |
| Head | 5~100 m |
| Speed | 1450/2900 r/min |
| Power | 1.5~37 kW |
| Operating temperature | −80~180 °C |
| Pressure rating | 1.6~2.5 MPa |
These are series ranges, not a replacement for an individual curve, bill of materials or order specification. Confirm temperature, pressure and medium conditions against the actual liner and configuration.

Equipment details and main construction
- 01 Casing construction: split double-layer arrangement. The equipment visual and seven part photographs show different construction layers; material and thickness details are given in the part notes.
- 02 Product construction: single-stage, single-suction, horizontal construction. Confirm the coupling arrangement for the selected model and order configuration.
- 03 Impeller design: optimized hydraulic model with a closed non-metallic impeller. Hydraulic performance and medium suitability remain subject to selection.
Product information
| Product name | MKF non-metallic magnetic-drive pump for media containing solids |
|---|---|
| Product model | MKF (series example) |
| Brand | Jiangsu Wuxin Pump Industry Co., Ltd. |
| Dimensions | Configured to customer requirements |
| Origin | Jingjiang, Jiangsu |
Main applications and boundaries
Suitable for chemical, pharmaceutical, petrochemical, paper-making, metal-smelting, food and wastewater-treatment industries, including media containing solid particles.
The available information does not state limits for particle concentration, size or hardness, and particle conditions must not be copied from another series. Confirm medium compatibility, temperature, pressure and installation for the actual duty.

01 Pump casing
The casing uses a split double-layer construction. The inner-shell wall is 8~12 mm thick, and its material can be selected for the medium and duty; this is not the liner thickness. The outer casing is a vertically split ductile-iron precision casting, with corrosion-resistant alloy steel also available. It carries system pressure and piping loads, and the inner and outer casings are separately replaceable.

02 Bearing bracket
An external leakage-monitoring alarm can be provided at the bearing bracket bottom to customer requirements. The casing bottom can also be configured with an external pipe, valve and medium-temperature sensor.

03 Impeller
The impeller uses an optimized hydraulic model and is a closed non-metallic impeller. It operates with stable axial and radial forces and provides high efficiency with a low required cavitation allowance.

04 Inner magnetic rotor
The inner magnetic rotor and impeller use a separate splined assembly, allowing torque adjustment or part replacement without replacing the complete assembly. The rotor is encapsulated with PFA or FEP fluoroplastic, so the conveyed liquid does not contact its metal body.

05 Outer magnetic rotor
The outer magnetic rotor uses samarium-cobalt permanent magnets, which maintain magnetic performance at high temperature. A safety-ring alarm may be configured at the outer-rotor front end and inside the bearing bracket to customer requirements.

06 Isolation sleeve
In the non-metallic double isolation sleeve, the outer sleeve withstands 1.6 MPa absolute pressure, while the shaft-seat sleeve has a 1.8 MPa internal design pressure and supports a medium temperature up to 180 °C. The two values apply to different construction parts and must be read separately.

07 Shaft, sliding bearing, wear ring and impeller ring
The shaft, sliding bearing, wear ring and impeller ring can use SSiC or SSiC+C+K; SSiC+C+K is suitable for media with larger solid particles and short no-lubricant duties.
Supplementary construction notes
- An external particle-stop ring is provided between the inner casing and isolation sleeve, and an internal particle-stop ring between the inner rotor and impeller.
- No-dry-running and overload-power protection are configurable.
Working conditions
| Working flow range | 3.2~50 m³/h |
|---|---|
| Working head range | 5~100 m |
| Configuration | Customizable to requirements |
This table lists flow, head and customization; see the performance table above for temperature. Customizability does not mean every material combination has been validated.

Model identification (series example)
MKF65-50-160AD/T
- MK
- Magnetic-drive pump series code
- F
- Material code
- 65
- Suction opening, in mm
- 50
- Discharge opening, in mm
- 160
- Nominal impeller diameter, in mm
- A
- Impeller trim code
- D/T
- D direct-coupled, T bracket-mounted; no suffix denotes shaft-coupled
Materials, construction and design notes
- Split double-layer casing: the inner-shell material is selected for the medium and duty, with an 8~12 mm wall. The outer casing can be a split ductile-iron or corrosion-resistant alloy-steel shell that carries system loads. Inner and outer casings are separately replaceable.
- Impeller, inner rotor and connection: the impeller and inner magnetic rotor use separate splined engagement. The metal rotor body is covered with fluoroplastic, and the connection arrangement is intended to simplify maintenance and replacement.
- Isolation sleeve and magnets: the shaft-seat double isolation sleeve has a 1.8 MPa internal design pressure and supports a medium temperature up to 180 °C, while the outer sleeve withstands 1.6 MPa absolute pressure. These values apply to different component parts and must not be combined into one whole-pump rating. Samarium-cobalt magnets are used.
- Shaft and bearings: a fixed-shaft, double-helical-groove sliding bearing is used, with optional SSiC+C+K, inner and outer particle-stop rings and configurable no-dry-running and overload-power protection.
- Standards reference: dimensions and performance parameters reference EN 22858/ISO 2858 and JB/T 7742-2013; confirm the applicable edition and scope in the selected model's technical documents.
Model and selection boundaries
The catalog model is MKF-L. In the model convention, D denotes direct-coupled and T bracket-mounted; confirm the supplied coupling arrangement for the selected configuration.
The 8~12 mm inner shell, the liner and the isolation sleeve are different construction layers. The 1.6 MPa absolute sleeve figure and 1.8 MPa design-pressure figure must not be combined into one whole-pump rating.
Performance values are series ranges. Confirm the individual curve, medium compatibility, solids, temperature, pressure, installation, protection options and formal technical documents for selection.
Product information
| Model designation | MKF-L Non-metal Magnetic-drive Pump |
|---|---|
| Catalog category | Non-metal Magnetic-drive Pump |
Related questions
How does a magnetic drive transfer motor torque to the impeller?
The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.
The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.