Products

IMCX-D Non-metal Magnetic-drive Pump

Home > Products > IMCX-D Non-metal Magnetic-drive Pump

IMCX-D Non-metal Magnetic-drive Pump

Product inquiry: 0523-84832479

Product introduction

The IMCX-D fluoroplastic-lined magnetic-drive pump is a direct-coupled model with fluoroplastic-lined wetted parts. Confirm the opening sizes and impeller dimensions for the selected configuration.

Product presentation

Dark-blue IMCX-D fluoroplastic-lined magnetic-drive pump brand visual showing the Jiangsu Wuxin Pump Industry Co., Ltd. name, thirty-years slogan, IMCX lettering, WUXIN PUMP mark, green pump casing, green motor, black base and blue diagonal stage.
  • High-temperature service
  • High mechanical strength
  • Long service life
  • Broad application range

These four capabilities summarize series features; confirm suitability for the medium, duty and selected configuration.

Model identification (series example)

IMCX65-40-200FD

IM
International-standard magnetic-pump series number
C
Lined construction code
X
New optimized-structure code
65
Suction opening size, in mm
40
Discharge opening size, in mm
200
Nominal impeller diameter, in mm
F
Wetted material code for major parts: F denotes FEP (F46)
D
Direct-coupled designation; shaft-coupled versions have no suffix
Oblique view of the IMCX-D fluoroplastic-lined magnetic-drive pump, showing the suction and discharge ends, green casing, green motor, black base, the complete pump assembly, blue markers and connecting lines.

Performance parameters

IMCX series performance range
Performance parameters
Suction openingDN25~DN250 mm
Flow1.5~700 m³/h
Head5~125 m
Speed1450~2900 r/min
Power1.5~200 kW
Operating temperature−80~150 °C
Pressure rating1.6 MPa

These are series ranges and do not replace an individual pump curve. Confirm the model, medium, lining material, temperature, pressure and official technical documents for selection.

Equipment details and main construction

  • 01 Selected material*: resistance to strong corrosion, oxidation, high and low temperature, and pressure.
  • 02 Special process*: precision-cast ductile iron.
  • 03 Double non-metallic outer isolation sleeve*: withstands 2.0 MPa internal pressure; reduces magnetic eddy-current loss and helps improve efficiency and reduce energy consumption, with a conveyed-medium temperature up to 150 °C.

Main applications and medium conditions

Suitable for clean liquids of various concentrations that are strongly corrosive or strongly oxidizing, including various acids, alkalis, salts, organic solvents and chemical reagents.

Working conditions

Working-condition parameters
Working conditions
Operating temperature range−80~150 °C; the actual range depends on the lining material and matches the performance-table temperature
ConfigurationCustomizable to requirements

The temperature range cannot be separated from the lining material. Customizability does not mean that every material combination has been validated; confirm the final configuration for the selected model.

IMCX-D fluoroplastic-lined magnetic-drive pump in the working-condition visual, showing the suction flange, green casing, green motor, black base and blue background.

Materials, construction and design notes

  • The casing is precision-cast in ductile iron. High-temperature sintering and molding bond the fluoroplastic lining to the volute as one assembly, maintaining a firm bond between the lining and the casing across temperature changes from −80 to 150 °C.
  • The double non-metallic outer isolation sleeve withstands 2.0 MPa internal pressure, reduces magnetic eddy-current loss and helps improve efficiency, and supports a conveyed-medium temperature up to 150 °C.
  • The impeller, inner magnetic rotor and coupling mechanism use a revised design intended to prevent rotor reversal, impeller-to-shaft loosening and related component damage caused by incorrect operation.
  • The sliding bearing and shaft sleeve use a silicon-carbide sleeve with a closed return-hole arrangement, allowing internal circulating lubricant to flow quickly from the isolation sleeve to the impeller return passage.
  • Separate axial sliding bearings and a radial plane bearing with locating feet address sudden duty changes and uneven axial loads.
  • The rear-pull maintenance arrangement allows internal inspection and part replacement without removing the pipeline, and helps reduce residual-liquid spillage during pull-back.
  • An integrated suspension and bearing housing uses larger front and smaller rear rolling bearings for higher load capacity, bearing life and outer-rotor stability. The bearing housing uses oil-bath lubrication and has good heat dissipation.
  • Performance and outline dimensions comply with ISO 2858 (GB 5662), ISO 5199 (GB/T 5656) and ISO 15783 (GB/T 25140).

Model and selection boundaries

The catalog model is IMCX-D, where D denotes direct coupling. The opening and impeller values in the series diagram are identification examples; confirm the order specification separately.

IMCX 65-40-200 F D illustrates the code structure. The 65, 40 and 200 values are identification examples; confirm the order code, openings, impeller diameter and configuration separately.

The 2.0 MPa figure is the design pressure of the double non-metallic outer isolation sleeve, while 1.6 MPa is the series pressure rating. They describe different structures and must not be combined or substituted for each other.

Performance values are series data and do not replace an individual pump curve, bill of materials or order specification. Temperature is also limited by the lining material; confirm final suitability against the medium, duty and official technical documents.

Product information

Model designationIMCX-D Non-metal Magnetic-drive Pump
Catalog categoryNon-metal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.