Products

MZF Non-metal Magnetic-drive Pump

Home > Products > MZF Non-metal Magnetic-drive Pump

MZF Non-metal Magnetic-drive Pump

Product inquiry: 0523-84832479

Product introduction

The MZF fluoroplastic-alloy magnetic-drive self-priming pump uses a guide-vane gas-liquid mixing self-priming principle and requires no check valve at the suction inlet. Confirm particle and installation conditions for the actual duty.

Product presentation

MZF magnetic-drive self-priming pump

Blue MZF fluoroplastic-alloy magnetic-drive self-priming pump brand visual with the Jiangsu Wuxin Pump Industry Co., Ltd. name, thirty-years slogan, MZF model lettering, product subtitle, white fluoroplastic pump body, green motor, mounting base and blue diagonal stage.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These capability highlights summarize the product construction; confirm performance and configuration in the selected model documentation.

Model identification (code example)

MZF65-50-160

MZ
Magnetic-drive self-priming pump series
F
Material code F50-1
65
Suction opening size, in mm
50
Discharge opening size, in mm
160
Nominal impeller diameter, in mm

MZF pump assembly and 01/02/03 structure details

MZF fluoroplastic-alloy magnetic-drive self-priming pump, showing the suction flange, white fluoroplastic pump body, green motor, mounting base and the 01/02/03 structural positions.

Performance parameters

MZF series performance ranges
Performance parameters
Suction openingDN25~DN80 mm
Flow3~50 m³/h
Head20~32 m
Speed1450~2900 r/min
Power1.5~15 kW
Operating temperature−40~120 °C
Pressure rating1.6~2.5 MPa
Self-priming height3~5.5 m

These are series performance ranges, not an individual pump curve or guarantee. Confirm the model, medium, material, temperature, pressure and official technical documents for selection.

Equipment details, 01/02/03 callouts and three-core guide

  • Independently developed, distinctive construction.
  • 01 Selected material: exceptionally strong corrosion and oxidation resistance.
  • 02 Special process: manufactured from fluoroplastic alloy.
  • 03 Guide-vane gas-liquid mixing self-priming principle: no check valve is required at the suction inlet; self-priming response is fast, self-priming height is high and the range of conveyable media is broad.

Main applications and conditions

For lifting and transferring strongly corrosive, strongly oxidizing, toxic or valuable chemical media from low-level pits, tanks and vessels.

Confirm medium compatibility, solids conditions, installation method and operating boundaries against the actual duty and official technical documents; do not infer them from the series application statement alone.

Working conditions

Working conditions
Working conditions
Operating temperature range−40~120 °C (depending on lining material)
ConfigurationCustomizable to requirements

The temperature range cannot be separated from the lining material. Customizability does not mean that every material combination has been validated; confirm the final configuration for the selected model.

MZF pump assembly in the working-condition visual

Complete MZF fluoroplastic-alloy magnetic-drive self-priming pump in an operating-condition visual, showing the suction flange, white pump body, green motor, mounting base, blue background and light-gray floor.

Materials, construction and design notes

  • Design notes: the construction at a glance.
  • The pump's wetted parts are made of fluoroplastic and provide good corrosion and oxidation resistance for a broad range of chemical-media duties.
  • A guide-vane gas-liquid mixing self-priming principle requires no check valve at the suction inlet. The construction features fast self-priming response, high self-priming height and a broad range of conveyable media.
  • Limited solids can be conveyed: solids content below 10 wt% and particle size at or below 100 mm. Particles must be soft and non-angular, such as floc, resin/plastic particles or crystalline salts.
  • Highly abrasive hard particles such as quartz sand are not suitable. The 100 mm particle-size upper bound is unusual and requires engineering review of particle size, shape and medium compatibility during selection.
  • A mobile trolley can be configured for some installations to serve multiple locations. The trolley is optional and is not included in every configuration.

Model and selection notes

For the MZF fluoroplastic-alloy magnetic-drive self-priming pump, F identifies material code F50-1; the example numbers explain the code structure.

MZ F 65-50-160 explains the code structure: MZ is the magnetic-drive self-priming series, F is material code F50-1, 65 is the suction opening, 50 the discharge opening and 160 the nominal impeller diameter, all in mm. Confirm the order code, openings, impeller diameter and configuration separately.

Performance values are series data and do not replace an individual pump curve, bill of materials or order specification. Working temperature also depends on the lining material.

The series does not require a suction check valve; the mobile trolley is an optional configuration. Confirm the medium, particles, temperature, pressure and installation method for the selected configuration.

Product information

Model designationMZF Non-metal Magnetic-drive Pump
Catalog categoryNon-metal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.