Products

IMCH-D Non-metal Magnetic-drive Pump

Home > Products > IMCH-D Non-metal Magnetic-drive Pump

IMCH-D Non-metal Magnetic-drive Pump

Product inquiry: 0523-84832479

Product introduction

The IMCH-D fluoroplastic-lined magnetic-drive pump is the direct-coupled identity and uses non-metallic wetted construction. Confirm the material, operating temperature and pressure rating for the selected configuration.

Product presentation

Dark-blue IMCH-D fluoroplastic-lined magnetic-drive pump brand visual showing the Jiangsu Wuxin Pump Industry Co., Ltd. name, thirty-years slogan, IMCH model lettering, fluoroplastic-lined magnetic-drive pump subtitle, WUXIN PUMP, green casing, coupling, green motor, black baseplate and blue diagonal stage.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These four capabilities summarize series features; confirm suitability for the medium, temperature, pressure and selected configuration.

Model identification (series example)

IMCH65-40-200FSSKD

IM
International-standard magnetic-pump series code
C
Fluoroplastic-lined construction code
H
Rear-pull safety/environmental construction code
65
Suction opening size, in mm
40
Discharge opening size, in mm
200
Nominal impeller diameter, in mm
F
Wetted-part material code; F denotes FEP (F46)
SS
Shaft-sleeve, sliding-bearing and dynamic/static-ring material code
K
Seal-ring material code
D / L
D denotes direct-coupled and L shaft-coupled; these are final model options, not fixed suffixes
IMCH-D direct-coupled equipment visual showing the suction flange, casing, coupling, motor, both mounting feet, black baseplate and 01/02/03 labeled construction points.

Performance parameters

IMCH series performance range
Performance parameters
Suction openingDN25~DN200 mm
Flow1.6~400 m³/h
Head5~125 m
Speed1450~2900 r/min
Power1.5~200 kW
Operating temperature−80~150 °C
Pressure ratingMPa; value not provided

These are series ranges, not an individual duty point. The IMCH-D pump-body pressure rating has not been provided and must not be replaced by the outer isolation sleeve's 1.6 MPa absolute pressure or product 53's performance value.

Equipment details and main construction

  • 01 Selected materials: resistance to strong corrosion, oxidation, high and low temperatures and pressure; confirm medium limits against the selected liner and wetted materials.
  • 02 Special process: the casing is precision-cast in ductile iron, then high-temperature molding and sintering tightly bond the fluoroplastic liner to the volute wall.
  • 03 Rear-pull safety and maintenance: for easier servicing, internal inspection can be performed without removing piping, and the withdrawn assembly can reduce residual-liquid spillage.

Main applications and conditions

Suitable for clean liquids of any concentration that are strongly corrosive or strongly oxidizing, including acids, alkalis, salt solutions, organic solvents and chemical reagents.

Suitable for chemical, pharmaceutical, environmental-protection and metallurgy industries. Confirm medium compatibility, concentration, temperature, pressure and cleanliness against the selected liner and wetted materials; an industry name alone is not a suitability guarantee.

Working conditions

Working-condition parameters
Working conditions
Operating temperature range−80~150 °C (depending on liner material)
ConfigurationCustomizable to requirements

The temperature range depends on the liner material; it is not a universal guarantee for every medium or individual pump. Customizability also does not mean every material combination has been validated.

IMCH-D direct-coupled working-condition equipment visual showing the suction flange, green casing, coupling, motor, both mounting feet, black baseplate, blue field and light-gray floor.

Materials, construction and design notes

  • The casing uses a split, double-layer construction. The inner casing wall is 8~12 mm thick, and its material can be selected for the chemical medium and duty. Static-vacuum protection is listed to 0 Pa; confirm the applicable conditions for the selected model.
  • The outer shell uses a vertically split half-clamp construction and can be fitted with drain, valve, temperature-sensor and leakage-alarm provisions; inspection does not require removing the piping.
  • The casing is precision-cast in ductile iron. Processing plus high-temperature molding and sintering tightly bond the fluoroplastic liner to the volute wall. The liner normally does not detach or delaminate within −80~150 °C; the metal casing retains mechanical strength while wetted parts provide strong corrosion, oxidation, high/low-temperature and pressure resistance.
  • The pump cover (isolation plate) uses an angled three-in/one-out guide-hole construction, with a metal insert framework and a fluoroplastic outer molding sintered at high temperature to circulate lubricating liquid in the bearing cavity.
  • The double non-metallic FEP/PFA isolation sleeve uses an outer sleeve with an absolute pressure of 1.6 MPa and produces no magnetic eddy current, helping reduce eddy-current loss and energy use. Medium temperature can reach 150 °C. This is an isolation-sleeve construction value, not the pump-body rating in the performance table.
  • The inner magnetic rotor and shaft use an integrated, fluoroplastic-covered construction to increase assembly stiffness. Samarium-cobalt permanent magnets provide stable magnetic performance and high torque transmission within the applicable temperature range.
  • The closed impeller uses optimized flow passages for high efficiency and low net positive suction head. It contains a large alloy-steel insert and is threaded to the inner magnetic rotor. Operation must follow the specified direction; reverse rotation is prohibited.
  • The shaft sleeve, sliding bearing and dynamic/static rings can use SiC, SSiC or SSiC+C+K; SSiC+C+K can tolerate brief loss-of-liquid dry running. Confirm the material against the medium, temperature and selected configuration.
  • The rear-pull construction permits internal inspection and part replacement without removing piping. The integrated suspension and bearing housing uses larger front and smaller rear rolling bearings; this feature applies only to the direct-coupled construction.
  • The bearings are grease-lubricated and the housing has an oil-storage structure. About 3,000 cumulative operating hours under normal conditions can be achieved before re-greasing; actual maintenance depends on speed, temperature, load and operating state.
  • Product performance and outline dimensions comply with ISO 2858 (GB/T 5662), ISO 5199 (GB/T 5656) and ISO 15783 (GB/T 25140). Selection still requires the selected model, dimension sheet and official technical documents.

Model and selection boundaries

The catalog model is IMCH-D, presented as the direct-coupled configuration. The model example is IMCH 65 -40 -200 F SS K D, where the final D denotes the direct-coupled option.

D and L denote direct-coupled and shaft-coupled respectively; they do not mean the series has only one coupling form. Direct-coupled-only traits such as the integrated bearing housing and larger-front/smaller-rear rolling bearings remain limited to that construction.

The IMCH-D pump-body pressure rating has not been provided and must not be replaced by the outer isolation sleeve's 1.6 MPa absolute pressure or product 53's 1.6 MPa performance value. The outer-sleeve value describes that component only.

Performance, temperature and construction values are series ranges or specific structural conditions. Final selection must confirm medium, liner, temperature, pressure, pump curve, installation dimensions and official technical documents.

Product information

Model designationIMCH-D Non-metal Magnetic-drive Pump
Catalog categoryNon-metal Magnetic-drive Pump

Related questions

How does a magnetic drive transfer motor torque to the impeller?

The motor rotates the outer magnet. Its field acts through the containment shell on the inner magnet, which drives the impeller through the model-specific shaft or connection.

The terms magnetic drive or static containment alone do not establish compatibility, dry-running allowance, solids capability, temperature/pressure limits or site risk.

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.