Product introduction

The UHB series slurry pump is a corrosion- and wear-resistant chemical centrifugal pump developed by the company over years for demanding media. It is a single-stage, single-suction pump. Its sealing arrangement combines a dynamic seal with a shutdown seal and includes the company-design patented internally mounted WXW mechanical seal.

Product presentation

UHB corrosion- and wear-resistant slurry pump image showing the company mark, model lettering, pump assembly, motor and baseplate.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

Confirm the final parameters, construction and materials for the selected model against the supplied technical documentation.

Product overview

The wetted parts of the UHB corrosion- and wear-resistant slurry pump use a steel-backed ultra-high-molecular-weight polyethylene (UHMWPE) engineering liner. The material combines mechanical, physical and chemical properties suited to wear, corrosion, impact, self-lubrication and low water absorption, and it resists the adhesion of foreign matter.

The series is presented for high temperature, high pressure and abrasive service, with high mechanical strength, practical economy and long service life across a broad range of corrosive and abrasive media.

Construction features

  • 01 Multifunctional pump*: one pump type can serve different operating duties.
  • 02 Effective sealing*: compact construction and long service life.
  • 03 Seal construction*: a dynamic seal and shutdown seal are combined with the company-designed C3 mechanical seal.

Product information

Product information listed for the UHB slurry pump
Product information
Product nameUHB Corrosion- and Wear-Resistant Slurry Pump
BrandJiangsu Wuxin Pump Industry Co., Ltd.
Product modelUHB
SizeCustomized to customer requirements
Place of originJingjiang, Jiangsu
Working conditionsHead range: 11m~80m; flow range: 3~600 m³/h
Application rangeChemical, non-ferrous metallurgy, environmental protection, papermaking, food, pharmaceutical and synthetic-fibre industries

Confirm the flow range for the selected model; performance values are stated in m³/h.

Main applications

For chemical, metallurgical, power, papermaking, food, pharmaceutical and synthetic-fibre plants handling slurries that contain acids, alkalis, solid particles or corrosive constituents.

  • Chemical and non-ferrous metallurgical plants
  • Environmental protection and power generation
  • Papermaking and synthetic fibre
  • Food and pharmaceutical production

Confirm media compatibility, solids conditions and the final material configuration against the selected model and actual duty.

Working conditions

UHB slurry pump working conditions
Working conditions
Head range11m~80m
Flow range3~600 m³/h
Working pressure rating1.0MPa
Pressure noteHigher working pressure can be supplied on request

These are series working ranges. Confirm the final configuration for the selected model and supplied technical documentation.

UHB slurry pump equipment view showing the green casing, coupling guard, motor and baseplate.

Design notes

  • 01 Pump construction: single-stage, single-suction. The company describes the series as a corrosion- and wear-resistant chemical centrifugal pump developed over years of work for demanding media.
  • 02 C3 seal assembly: an internally mounted, non-standard mechanical seal designed by the company, using external cooling and requiring cooling water. The balanced seal automatically adjusts face pressure according to liquid pressure.
  • 03 Discharge layout: on pumps with an inlet greater than 150mm, the discharge position is opposite that of pumps with an inlet smaller than 125mm.

Product information

Model designationUHB Corrosion- and Wear-Resistant Slurry Pump
Catalog categoryNon-metallic Corrosion-resistant Pump

Related questions

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

What minimum solids data is needed for slurry-pump selection?

Provide at least mass/volume solids content, size distribution and maximum size, hardness, shape, density, settling and crystallisation/agglomeration behaviour.

No UHB-specific detail is published while its text layer remains incomplete; any solids range or material life requires model-primary-source review.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.