HFM Reverse-Suction Non-Metallic Corrosion- and Wear-Resistant Slurry Pump (Plate-and-Frame Filter Press Pump)
Product inquiry: 0523-84832479Product introduction
The HFM reverse-suction non-metallic corrosion- and wear-resistant slurry pump is used for duties including plate-and-frame filter-press service, with a reverse-suction arrangement and UHMWPE wetted components.
Product presentation

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These performance advantages depend on the medium, duty and selected model.
MODEL IDENTIFICATION - example 80 HFM -ZK (ZJ) -50 -30, nomenclature only
80HFM-ZK(ZJ)-50-30
- 80
- Suction opening, in mm
- HFM
- Reverse-suction non-metallic slurry pump
- -ZK
- Power-seal code
- (ZJ)
- Mechanical-seal code, configured for the duty
- -50
- Rated flow, in m³/h
- -30
- Rated head, in m
HFM reverse-suction pump assembly

HFM reverse-suction non-metallic slurry pump: selected details / independently developed, distinctive construction
- 01 Selected material: good corrosion resistance and oxidation resistance.
- 02 Special construction: single-suction, single-stage cantilever arrangement with the suction inlet at the low-pressure side.
- 03 The suction inlet is located at the rear of the volute casing, changing the former high-pressure shaft-seal region into a low-pressure region.
Performance parameters
| Suction opening | DN32~DN300 mm |
|---|---|
| Operating temperature | −70~80 °C |
| Flow | 2.5~1600 m³/h |
| Pressure rating | 1.6 MPa |
| Head | 3~50 m |
| Speed | 1450/2900 r/min |
| Power | 1.1~250 kW |
These are HFM series parameter ranges, not guarantees for an individual model. Confirm the medium, flow, head, temperature, solids content, particle size, materials, seal and motor configuration during selection.
01 Main applications: broad application range
Suitable for conveying corrosive media containing acids, alkalis or salts, and slurries containing solid particles.
The pump can be matched to plate-and-frame filter-press feed duties. Determine solids content, particle size, concentration and temperature through medium compatibility and selection.
Select the pump for the pressure requirement of the filter-press feed duty; do not assume that this duty applies unchanged to other slurry-pump installations.
02 Working conditions: customizable to requirements
| Operating temperature range | −70~80 °C (depending on lining material) |
|---|---|
| Configuration | Customizable to requirements |
The operating-temperature range depends on the lining material. Confirm suitability against the medium, solids content, particle size, concentration and selected configuration.
HFM reverse-suction pump working position

03 Design notes: construction and seal materials
- The pump uses a single-suction, single-stage cantilever arrangement with the suction inlet at the low-pressure side; its wetted components are made from ultra-high-molecular-weight polyethylene (UHMWPE).
- Ultra-high-molecular-weight polyethylene offers good wear resistance, impact resistance and self-lubrication, with a low friction coefficient, low water absorption, resistance to adhering foreign matter, good corrosion resistance and good low-temperature performance.
- Locating the suction inlet at the rear of the volute turns the former high-pressure shaft-seal region into a low-pressure region. Lower mechanical-seal pressure reduces the chance of solids entering the seal chamber and can help extend seal life in solids-bearing service. Material and duty still require compatibility and selection confirmation.
Product information
| Model designation | HFM Reverse-Suction Non-Metallic Corrosion- and Wear-Resistant Slurry Pump (Plate-and-Frame Filter Press Pump) |
|---|---|
| Catalog category | Non-metallic Corrosion-resistant Pump |
Related questions
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
What minimum solids data is needed for slurry-pump selection?
Provide at least mass/volume solids content, size distribution and maximum size, hardness, shape, density, settling and crystallisation/agglomeration behaviour.
No UHB-specific detail is published while its text layer remains incomplete; any solids range or material life requires model-primary-source review.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.