HYF Fluoroplastic Alloy Submerged Pump
Product inquiry: 0523-84832479Product introduction
The HYF non-metallic submerged pump has been improved through structural, material-selection and process changes to strengthen corrosion resistance, wear resistance, structural suitability, duty adaptability and service life.
Product presentation

Product overview
The HYF is a non-metallic-material submerged pump. Ongoing structural, material and process improvements target stronger corrosion and wear resistance, sounder construction, broader duty suitability and longer service life.
Construction and features
- Bearing design: a thrust bearing in the bearing housing carries the axial force produced by the impeller during operation.
- Bearing support: a split sleeve-type sliding bearing is installed midway along the support column and is made from carbon-fibre-filled corrosion-resistant, wear-resistant non-metallic material. It is secured by an external reinforced-plastic split holder fixed to the intermediate support column.
- Lubrication and flushing: the holder has a small hole through which liquid can enter the bearing groove for flushing and lubrication.
- Lower bearing: a carbon-fibre-filled non-metallic sliding bearing is keyed into the pump-cover bearing cavity and secured by the cover's retaining nut.
- Sealing: a labyrinth dynamic seal is installed in the bearing housing, mounting plate and support column, with an additional static parking seal ahead of it. This arrangement reduces the risk of corrosive-gas leakage while stopped and high-liquid-level overflow.
Materials and temperature conditions
- Fluoroplastic alloy (F50-1, F50-2): for strongly corrosive, strongly oxidizing, wear-resistant and high-temperature duties, with a service temperature of up to 120°C.
- Reinforced polypropylene (FRPP): for a defined range of corrosive duties, with a service temperature of up to 80°C.
- Ultra-high-molecular-weight polyethylene (UHMWPE): for a defined range of corrosive and wear-resistant duties, at -40°C to +65°C.
Model designation
80HYF-30
- 80
- Pump suction diameter (mm)
- HY
- Chemical submerged pump
- F
- Material code: F = fluoroplastic, R = reinforced polypropylene, U = UHMWPE
- 30
- Pump head (m)
Performance data
A model can be supplied with several submerged lengths, each listed as a separate row.
| Model | Flow (m³/h) | Head (m) | Suction inlet (mm) | Discharge outlet (mm) | Motor (kW) | Speed (r/min) | Submerged length (mm) | Pump efficiency η (%) |
|---|---|---|---|---|---|---|---|---|
| 25HYF-20 | 3.6 | 20 | 25 | 20 | 1.5 | 2900 | 500 / 1000 / 1500 / 2000 | 22 |
| 25HYF-30 | 3.6 | 20 | 25 | 20 | 2.2 | 2900 | 500 / 1000 / 1500 / 2000 | 18 |
| 32HYF-20 | 6.5 | 20 | 32 | 25 | 2.2 | 2900 | 500 / 1000 / 1500 / 2000 | 26 |
| 32HYF-30 | 6.5 | 30 | 32 | 25 | 4 | 2900 | 500 / 1000 / 1500 / 2000 | 23 |
| 40HYF-20 | 10 | 20 | 40 | 32 | 3 | 2900 | 500 / 1000 / 1500 / 2000 | 32 |
| 40HYF-30 | 10 | 30 | 40 | 32 | 4 | 2900 | 500 / 1000 | 26 |
| 50HYF-20 | 15 | 20 | 50 | 40 | 3 | 2900 | 500 / 1000 / 1500 / 2000 | 42 |
| 50HYF-25 | 15 | 25 | 50 | 40 | 4 | 2900 | 1000 / 1500 / 2000 / 2500 | 38 |
| 65HYF-20 | 25 | 20 | 65 | 50 | 5.5 | 2900 | 1000 / 1500 / 2000 / 2500 | 49 |
| 65HYF-30 | 25 | 30 | 65 | 50 | 7.5 | 2900 | 1000 / 1500 / 2000 / 2500 | 45 |
| 65HYF-40 | 25 | 40 | 65 | 40 | 11 | 2900 | 1000 / 1500 / 2000 / 2500 | 41 |
| 80HYF-20 | 50 | 20 | 80 | 65 | 7.5 | 2900 | 1000 / 1500 / 2000 / 2500 | 52 |
| 80HYF-30 | 50 | 30 | 80 | 65 | 11 | 2900 | 1000 / 1500 / 2000 / 2500 | 51 |
| 80HYF-40 | 50 | 40 | 80 | 40 | 15 | 2900 | 1000 / 1500 / 2000 / 2500 | 49 |
| 100HYF-20 | 100 | 20 | 100 | 80 | 15 | 2900 | 1000 / 1500 / 2000 / 2500 | 57 |
| 100HYF-25 | 100 | 25 | 100 | 80 | 18.5 | 2900 | 1000 / 1500 / 2000 / 2500 | 55 |
| 100HYF-40 | 100 | 40 | 100 | 65 | 30 | 2900 | 500 / 1000 / 1500 / 2000 | 53 |
| 100HYF-50 | 100 | 50 | 100 | 65 | 37 | 2900 | 500 / 1000 / 1500 / 2000 | 53 |
| 125HYF-10 | 150 | 10 | 125 | 100 | 11 | 1450 | 1500 / 2000 / 3000 / 4000 | 58 |
| 125HYF-15 | 150 | 15 | 125 | 100 | 18.5 | 1450 | 1500 / 2000 / 3000 / 4000 | 57 |
| 125HYF-20 | 150 | 20 | 125 | 100 | 22 | 1450 | 1500 / 2000 / 3000 / 4000 | 56 |
| 125HYF-30 | 150 | 30 | 125 | 100 | 37 | 1450 | 1500 / 2000 / 2500 / 3000 | 55 |
| 125HYF-40 | 150 | 40 | 125 | 100 | 45 | 1450 | 1500 / 2000 / 2500 / 3000 | 53 |
| 125HYF-50 | 150 | 50 | 125 | 100 | 55 | 1450 | 1500 / 2000 / 2500 / 3000 | 53 |
| 150HYF-10 | 200 | 10 | 150 | 125 | 15 | 1450 | 1000 / 1500 / 2000 / 3000 | 62 |
| 150HYF-15 | 200 | 15 | 150 | 125 | 22 | 1450 | 1000 / 1500 / 2000 / 3000 | 60 |
| 150HYF-20 | 200 | 20 | 150 | 125 | 30 | 1450 | 1000 / 1500 / 2000 / 3000 | 58 |
Note: contact the supplier when a submerged length above 2500 mm is required. Confirm the listed data, material, speed and motor selection against the pumped medium and actual duty, and with the formal technical documentation.
Selection and operating notes
Submerged lengths of 500/1000/1500/2000/2500/3000/4000 mm are available options, not a guarantee that every model is available in every length. Use the matching row and the formal technical documentation.
One model does not cover every submerged length; confirm the final configuration in the formal technical documentation.
Product information
| Model designation | HYF Fluoroplastic Alloy Submerged Pump |
|---|---|
| Catalog category | Non-metallic Corrosion-resistant Pump |
Related questions
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
Why are vessel dimensions required for submerged-pump selection?
Vessel depth, opening, mounting plane, obstructions and suction location determine immersion, mounting plate, supports and maintenance space; one level value is insufficient.
Do not infer site performance from patents, collaboration statements or family names; depth and interfaces remain unconfirmed until the installation drawing is reviewed.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.