WNP Reinforced Non-metallic Corrosion- and Wear-Resistant Chemical Centrifugal Pump
Product inquiry: 0523-84832479Product introduction
The WNP clamp-reinforced all-plastic corrosion- and wear-resistant chemical centrifugal pump uses a molded all-plastic casing with external metal clamping plates; the impeller, wetted material and mechanical seal are selected for the medium.
Product presentation

- High-temperature resistance
- High mechanical strength
- Long service life
- Broad application range
These capability highlights summarize the product construction; confirm performance and configuration in the selected model documentation.
MODEL IDENTIFICATION - example WNP 80-50-250 A
WNP80-50-250A
- WN
- Wuxin corrosion- and wear-resistant plastic centrifugal pump series
- P
- Wetted-part material code
- 80 / 50
- Suction/discharge opening sizes, in mm
- 250
- Nominal impeller diameter, in mm
- A / B / C
- Impeller trimming code
WNP all-plastic pump assembly

WNP clamp-reinforced all-plastic corrosion- and wear-resistant chemical centrifugal pump: selected details
- 01 Selected materials: wetted parts use engineering plastics filled with GF, CF or other reinforcements, selected for the medium and temperature.
- 02 Special construction: the casing is molded in all-plastic material and reinforced by external metal clamping plates that carry piping loads and increase overall rigidity; they are not decorative covers.
- 03 Impeller and cover: closed or semi-open impellers use a high-strength metal insert and thickened plastic body; the large-volume all-plastic cover is intended for particle-bearing or crystallizing media.
- 04 Shaft seal: internally mounted double-face or single-face unbalanced mechanical seals are available, with fluoroplastic-covered sleeves and springs; a double-face seal can follow API 682 Plan 54.
Performance parameters
| Suction opening | DN40~DN250 mm |
|---|---|
| Flow | 3~800 m³/h |
| Head | 5~100 m |
| Speed | 1450/2900 r/min |
| Power | 1.5~160 kW |
| Operating temperature | −80~200 °C |
| Pressure rating | 1.6 MPa |
These are series ranges, not a duty point or guarantee for an individual pump. Confirm performance, materials, seals and motor configuration against the medium, duty and formal technical documents.
01 Main applications: broad application range
For acid, alkali and salt solutions and crystallizing media, with solids content no greater than 30 wt%, particle diameter no greater than 3 mm, and kinematic viscosity no greater than 30×10⁻⁶ m²/s (30 cSt, measured at operating temperature).
Confirm concentration, temperature, particle hardness and compatibility with the selected wetted plastics and seal materials against the specific duty.
02 Working conditions: customizable to requirements
| Operating temperature range | −80~200 °C (depending on lining material) |
|---|---|
| Solids and particle limits | Solids ≤30 wt%; particle diameter ≤3 mm |
| Kinematic-viscosity limit | ≤30 cSt (measured at operating temperature) |
| Clamping and seal | External metal clamping plates; WXS1/WXS2 selected for duty |
Confirm the temperature window, medium conditions and solids limits for the specific medium and selected configuration.
WNP all-plastic pump working position

03 Design notes: construction and materials
- The casing is molded in all-plastic material and reinforced by external metal clamping plates that carry piping loads and increase overall rigidity. The plates are part of the load-bearing and installation structure, not decorative covers.
- Wetted plastics can use glass-fiber (GF), carbon-fiber (CF) and other filled compounds to improve rigidity, strength, wear resistance, temperature capability and corrosion resistance; select the compound for the medium and temperature.
- Closed or semi-open impellers contain a high-strength metal insert with a thickened plastic body. The large-volume all-plastic cover is intended for solids-bearing or crystallizing media and can reduce the effect of accumulated particles or crystals on the mechanical seal.
- Shaft-seal options include WXS1 single-face or WXS2 double-face unbalanced mechanical seals with fluoroplastic-covered sleeves and springs. SiC/SSiC faces and FKM, FFKM or EPDM O-rings are available; double-face seals can use API 682 Plan 54 flush and cooling.
Product information
| Model designation | WNP Reinforced Non-metallic Corrosion- and Wear-Resistant Chemical Centrifugal Pump |
|---|---|
| Catalog category | Non-metallic Corrosion-resistant Pump |
Related questions
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
How is the duty point of a chemical centrifugal pump determined?
Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.