Product introduction

The FZB□-□-□ and FZB□-□-□(L) fluoroplastic-alloy self-priming corrosion-resistant centrifugal pumps combine several high-technology advantages. They change the limitations imposed on conventional check valves by the pumped medium and the vulnerability of check flaps. Using our company's technology and design, the pumps improve self-priming time and suction lift, and offer an attractive appearance, simple construction, easy installation and disassembly, low maintenance, long service life and a wide media range.

Product presentation

Product overview

FZB and FZB-L belong to the same series. FZB models without a final L are close-coupled; FZB-L models are coupled to the motor and mounted on a common base. Wetted flow passages are made from F50-1 or F50-2 fluoroplastic alloy, which resists corrosion and oxidation. The service-temperature range is -40 °C to 120 °C. Confirm media compatibility for the concentration, temperature and selected material.

FZB close-coupled and FZB-L coupled fluoroplastic-alloy self-priming corrosion-resistant centrifugal pumps

Construction and features

  • The self-priming arrangement does not use a conventional check valve, reducing media restrictions and avoiding damage-prone check flaps.
  • Self-priming performance depends on the installation, piping and pumped medium. Confirm performance for the selected configuration.
  • FZB is close-coupled; FZB-L is a coupled design with a base.

Model designation

FZB50-32-125L

F
Fluoroplastic material for the wetted flow passages
ZB
Self-priming centrifugal pump
50
Suction inlet diameter (mm, obtained after diameter reduction)
32
Discharge outlet diameter (mm)
125
Nominal impeller diameter
L
Coupled design with base; without L, close-coupled

Performance parameters

22 model configurations

FZB fluoroplastic-alloy self-priming corrosion-resistant centrifugal pump performance data
Specifications & modelFlow (m³/h)Head (m)Suction inlet (mm)Discharge outlet (mm)Motor (kW)Speed (r/min)Allowable suction lift (m)Allowable self-priming time (s)Efficiency η (%)
FZB25-25-12532025251.52900318026
FZB25-25-125L32025251.52900318026
FZB32-32-12552032322.22900318028
FZB32-32-125L52032322.22900318028
FZB40-40-12582040402.229003.524037
FZB40-40-125L82040402.229003.524037
FZB40-40-1608304040329003.524030
FZB40-40-160L8304040329003.524030
FZB50-50-12512.5205050329004.524048
FZB50-50-125L12.5205050329004.524048
FZB50-50-16012.5305050429004.524043
FZB50-50-160L12.5305050429004.524043
FZB65-65-1252520656542900530058
FZB65-65-125L2520656542900530058
FZB65-65-160253065655.52900530053
FZB65-65-160L253065655.52900530053
FZB80-80-125502080805.52900530062
FZB80-80-125L502080805.52900530062
FZB80-80-16050308080112900530060
FZB80-80-160L50308080112900530060
FZB100-80-1251002010080112900630068
FZB100-80-125L1002010080112900630068

Confirm the selected model, configuration and performance against the quotation and supplied technical documentation.

Product note

The company continually develops its products, reserves the right to make technical changes, and will provide detailed information on request.

Applications

Suitable applications include:

  • Lifting and transfer of chemical media from underground storage tanks and pools
  • Unloading strongly corrosive media from ships and road tankers
  • Replacement of long-shaft sump pumps
  • Other duties suited to this series

Design and selection boundaries

Confirm the following during selection and use:

  • The service-temperature range is -40 °C to 120 °C. Confirm media compatibility, concentration and duty suitability for the specific application.
  • Verify compatibility for each medium, concentration and temperature; the series range alone does not establish compatibility.
  • Flow, head, suction lift, self-priming time and efficiency are series values. Confirm actual performance against the selected model, motor configuration and supplied technical documentation.
  • Confirm the pressure rating, NPSH and detailed installation dimensions for the selected model.
  • FZB is close-coupled; FZB-L is a coupled design with a base.

Confirm the final configuration and performance against the selected model and supplied technical documentation.

Product information

Model designationFZB Fluoroplastic Alloy Self-Priming Pump
Catalog categoryNon-metallic Corrosion-resistant Pump

Related questions

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

Does a self-priming pump need no filling on its first start?

Usually not. Most self-priming designs still require the casing to contain the specified liquid under the model manual; the exact method is model-specific.

Fill volume, valve position, suction lift and priming time depend on the model and site layout; follow the site procedure and the manual for the exact model.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.