Products

IHG-F Non-metallic Corrosion-resistant Pump

Home > Products > IHG-F Non-metallic Corrosion-resistant Pump

IHG-F Non-metallic Corrosion-resistant Pump

Product inquiry: 0523-84832479

Product introduction

The IHG-F fluoroplastic-lined vertical inline centrifugal pump has equal-size inlet and outlet openings on the same centerline and can be installed in line like a valve. Confirm the wetted materials and mechanical seal against the medium and duty.

Product presentation

IHG-F fluoroplastic-lined vertical inline centrifugal pump

IHG-F fluoroplastic-lined vertical inline centrifugal pump, showing the green vertical casing, coaxial flanges, motor and support base.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These performance advantages depend on the medium, temperature, duty and selected model.

MODEL IDENTIFICATION - example IHG 50 -160 F 4/2, nomenclature only

IHG50-160F4/2

IHG
Single-suction, single-stage inline centrifugal pump
50
Pump inlet and outlet diameter, in mm
-160
Nominal impeller diameter, in mm
F
Fluoroplastic lining code
4/2
Motor pole number

IHG-F vertical inline pump construction

IHG-F fluoroplastic-lined vertical inline centrifugal pump, showing the green motor, casing, inlet and outlet flanges on a common centerline, short branches, mounting support and base.

IHG-F fluoroplastic-lined vertical inline centrifugal pump: selected details / independently developed, distinctive construction

  • 01 Selected material: good corrosion resistance and oxidation resistance.
  • 02 Special construction: vertical inline arrangement with equal inlet and outlet diameters on the same centerline.
  • 03 Easy installation and maintenance: the piping does not need to be dismantled; remove the pump casing and support bolts, then withdraw the complete rotor assembly.

Performance parameters

IHG-F fluoroplastic-lined vertical inline centrifugal pump series parameters
Suction openingDN20~DN100 mm
Operating temperature−80~160 °C
Flow1.8~100 m³/h
Pressure rating1.6 MPa
Head12~80 m
Speed1450/2900 r/min
Power0.75~45 kW

These are IHG-F series parameter ranges, not guarantees for an individual model. Confirm the medium, flow, head, temperature, materials, seal, motor and installation conditions during selection.

01 Main applications: broad application range

The wetted flow path uses an internal fluoroplastic lining and external wrapping and can convey corrosive media such as acid, alkali and salt solutions, oxidizing media and organic solvents.

The vertical inline arrangement can be installed directly in the piping like a valve. Its compact footprint reduces civil-work and auxiliary-facility requirements.

The shaft seal can use different non-metallic mechanical-seal materials according to medium corrosivity, temperature, viscosity and solids content. Confirm specific media against material compatibility.

Confirm the medium, concentration, temperature, solids conditions and operating range against the selected model and formal technical documents.

02 Working conditions: customizable to requirements

IHG-F fluoroplastic-lined vertical inline centrifugal pump working conditions
Operating temperature range−80~160 °C (depending on lining material)
ConfigurationCustomizable to requirements

The operating-temperature range depends on the lining material. Confirm suitability against the medium, concentration and selected configuration.

IHG-F vertical inline pump working position

IHG-F vertical inline pump on a light-gray floor, showing the green motor, casing, inlet and outlet flanges on a common centerline, short branches, mounting support and base.

03 Design notes: inline installation and maintenance

  • The pump uses a vertical inline arrangement with equal inlet and outlet diameters on the same centerline and can be installed directly in the piping like a valve. Its compact footprint reduces space requirements.
  • For outdoor installation, provide rain, dust and freeze protection appropriate to the environment, and use a motor enclosure rated for outdoor service.
  • Installation and maintenance are straightforward: the piping does not need to be dismantled. Remove the bolts connecting the pump casing and support, then withdraw the complete rotor assembly.
  • Confirm the applicable medium against material compatibility and the actual duty.

Wetted construction, materials and seal boundaries

  • The wetted flow path uses an internal fluoroplastic lining and external wrapping and can convey corrosive media such as acid, alkali and salt solutions, oxidizing media and organic solvents.
  • The mechanical seal can use different non-metallic materials according to the user's duty, including medium corrosivity, temperature, viscosity and solids content, to suit different media and help extend seal and pump service life.
  • Confirm the applicable medium, concentration, temperature and operating limits against material compatibility, the selected model and formal technical documentation.

Product information

Model designationIHG-F Non-metallic Corrosion-resistant Pump
Catalog categoryNon-metallic Corrosion-resistant Pump

Related questions

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

How is the duty point of a chemical centrifugal pump determined?

Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.

Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.