IHF-D Fluoroplastic-Lined Chemical Centrifugal Pump
Product inquiry: 0523-84832479Product introduction
The wetted passages of the IHF lined fluoroplastic chemical centrifugal pump use FEP (F46) or PFA. After high-temperature sintering by a special process, the lining is molded and processed together with the pump body and components. The fluoroplastic and metal parts are tightly and firmly anchored as one body, providing “steel-like strength” comparable to that of a metal pump while resisting a range of chemical media. The construction supports high-temperature, high-pressure and strongly corrosive service, high mechanical strength, long service life and a wide application range.
Product presentation

Product overview
The IHF-D fluoroplastic-lined chemical centrifugal pump is the close-coupled product in the IHF series. Confirm the model identification against the equipment nameplate, order designation and technical documentation.
The series serves corrosive-liquid transfer in chemical and related industries. Wetted-material options include FEP (F46), PFA and F50-1; the final material, seal and construction must be confirmed against the medium and duty.
The IHF series offers shaft-coupled and close-coupled arrangements; the IHF-D is close-coupled, while shaft-coupled models do not carry the D designation. Performance and external mounting dimensions follow GB/T 5662, EN 22858 and ISO 2858; mechanical-seal and cooling/flush arrangements are selected for the duty.
The fluoroplastic is anchored to the metal components as one body, combining structural rigidity with resistance to a range of chemical media. The construction is intended for high-temperature, high-pressure and strongly corrosive service and offers high mechanical strength, long service life and a wide application range. Confirm actual suitability against the specific medium, concentration, temperature, pressure and duty, with the selection result and supplied technical documentation.
Model designation
IHF(N)100-65-200D
- I
- Conforms to GB/T 5662, ISO 2858 and EN 22858
- H
- Chemical centrifugal pump
- F
- Wetted-passage material code (see material codes)
- (N)
- Mechanical-seal code (see seal codes; omitted when unmarked)
- 100
- Pump inlet diameter (mm)
- -65
- Pump outlet diameter (mm)
- -200
- Nominal impeller diameter (mm)
- D
- Direct-coupled type; the shaft-coupled type is unmarked
Mechanical-seal codes
- Unmarked: WB2 or 169 external single-end-face mechanical seal.
- “N”: WX8D internal double-end-face mechanical seal.
- “S”: WXS1/WXS2 internal single- or double-end-face mechanical seal.
- “W”: WXW mechanical seal.
- “Z”: mechanical seal with self-flushing.
Wetted-passage material codes
- A: PFA (soluble PTFE).
- F: FEP (F46), fluorinated ethylene propylene.
- U: UHMWPE, ultra-high-molecular-weight polyethylene.
- V: PVDF, polyvinylidene fluoride.
- FF: F50-1 fluoroplastic alloy.
Performance data (page 1, n = 2900 r/min)
Density groups are 1.0 / 1.35 / 1.84 g/cm³.
| Model | Flow Q (m³/h) | Flow Q (L/min) | Head H (m) | NPSHr (m) | Motor power at 1.0 g/cm³ (kW) | Motor power at 1.35 g/cm³ (kW) | Motor power at 1.84 g/cm³ (kW) |
|---|---|---|---|---|---|---|---|
| 25-20-125 | 3.0 | 49.8 | 20 | 3.0 | 0.75 | 1.1 | 1.5 |
| 25-20-160 | 3.0 | 49.8 | 32 | 3.0 | 1.5 | 2.2 | 3 |
| 32-25-125 | 4.5 | 74.7 | 20 | 3.0 | 1.1 | 1.5 | 2.2 |
| 32-25-160 | 4.5 | 74.7 | 32 | 3.0 | 1.5 | 2.2 | 3 |
| 40-25-125 | 6.3 | 104.6 | 20 | 3.2 | 1.1 | 1.5 | 2.2 |
| 40-25-160 | 6.3 | 104.6 | 32 | 3.2 | 2.2 | 3 | 4 |
| 40-25-200 | 6.3 | 104.6 | 50 | 3.2 | 3 | 4 | 5.5 |
| 40-25-250 | 6.3 | 104.6 | 80 | 3.2 | 5.5 | 7.5 | 11 |
| 50-32-125 | 12.5 | 207.5 | 20 | 3.5 | 1.5 | 2.2 | 3 |
| 50-32-160 | 12.5 | 207.5 | 32 | 3.5 | 3 | 4 | 5.5 |
| 50-32-200 | 12.5 | 207.5 | 50 | 3.5 | 5.5 | 7.5 | 11 |
| 50-32-250 | 12.5 | 207.5 | 80 | 3.5 | 11 | 11 | 15 |
| 65-50-125 | 25 | 415 | 20 | 4.0 | 3 | 4 | 5.5 |
| 65-50-160 | 25 | 415 | 32 | 4.0 | 5.5 | 7.5 | 11 |
| 65-40-200 | 25 | 415 | 50 | 4.0 | 7.5 | 11 | 15 |
| 65-40-250 | 25 | 415 | 80 | 4.0 | 15 | 18.5 | 30 |
| 65-40-315 | 25 | 415 | 125 | 4.0 | 30 | 37 | 45 |
| 80-65-125 | 50 | 830 | 20 | 4.0 | 5.5 | 7.5 | 11 |
| 80-65-160 | 50 | 830 | 32 | 4.0 | 7.5 | 11 | 15 |
| 80-50-200 | 50 | 830 | 50 | 4.0 | 15 | 18.5 | 30 |
| 80-50-250 | 50 | 830 | 80 | 4.0 | 30 | 37 | 45 |
| 80-50-315 | 50 | 830 | 125 | 4.0 | 37 | 55 | 75 |
| 100-80-125 | 100 | 1660 | 20 | 4.0 | 11 | 15 | 18.5 |
| 100-80-160 | 100 | 1660 | 32 | 4.0 | 15 | 22 | 30 |
| 100-65-200 | 100 | 1660 | 50 | 4.0 | 30 | 37 | 45 |
| 100-65-250 | 100 | 1660 | 80 | 4.0 | 45 | 55 | 75 |
| 100-65-315 | 100 | 1660 | 125 | 4.0 | 75 | 90 | 132 |
| 125-80-160 | 160 | 2656 | 32 | 4.5 | 22 | 30 | 45 |
| 125-80-200 | 160 | 2656 | 50 | 4.5 | 37 | 45 | 75 |
| 125-80-250 | 160 | 2656 | 80 | 4.5 | 55 | 75 | 132 |
| 125-80-315 | 160 | 2656 | 125 | 4.5 | 90 | 132 | 200 |
| 125-80-400 | 160 | 2656 | - | 4.5 | - | - | - |
Performance data (page 1, n = 1450 r/min)
Density groups are 1.0 / 1.35 / 1.84 g/cm³.
| Model | Flow Q (m³/h) | Flow Q (L/min) | Head H (m) | NPSHr (m) | Motor power at 1.0 g/cm³ (kW) | Motor power at 1.35 g/cm³ (kW) | Motor power at 1.84 g/cm³ (kW) |
|---|---|---|---|---|---|---|---|
| 25-20-125 | - | - | - | - | - | - | - |
| 25-20-160 | - | - | - | - | - | - | - |
| 32-25-125 | - | - | - | - | - | - | - |
| 32-25-160 | - | - | - | - | - | - | - |
| 40-25-125 | 3.2 | 53.1 | 5 | 1.5 | - | - | 0.55 |
| 40-25-160 | 3.2 | 53.1 | 8 | 1.5 | - | - | 0.55 |
| 40-25-200 | 3.2 | 53.1 | 12.5 | 1.5 | 0.55 | 0.75 | 1.1 |
| 40-25-250 | 3.2 | 53.1 | 20 | 1.5 | 1.1 | 1.5 | 2.2 |
| 50-32-125 | 6.3 | 104.6 | 5 | 1.7 | - | 0.55 | 0.75 |
| 50-32-160 | 6.3 | 104.6 | 8 | 1.7 | 0.75 | 1.1 | 1.5 |
| 50-32-200 | 6.3 | 104.6 | 12.5 | 1.7 | 1.1 | 1.5 | 2.2 |
| 50-32-250 | 6.3 | 104.6 | 20 | 1.7 | 2.2 | 3 | 4 |
| 65-50-125 | 12.5 | 207.5 | 5 | 2 | - | 0.55 | 0.75 |
| 65-50-160 | 12.5 | 207.5 | 8 | 2 | 0.75 | 1.1 | 1.5 |
| 65-40-200 | 12.5 | 207.5 | 12.5 | 2 | 1.1 | 1.5 | 2.2 |
| 65-40-250 | 12.5 | 207.5 | 20 | 2 | 2.2 | 3 | 4 |
| 65-40-315 | 12.5 | 207.5 | 32 | 2 | 4 | 5.5 | 7.5 |
| 80-65-125 | 25 | 415 | 5 | 2 | 0.75 | 1.1 | 1.5 |
| 80-65-160 | 25 | 415 | 8 | 2 | 1.1 | 1.5 | 2.2 |
| 80-50-200 | 25 | 415 | 12.5 | 2 | 2.2 | 3 | 4 |
| 80-50-250 | 25 | 415 | 20 | 2 | 3 | 4 | 5.5 |
| 80-50-315 | 25 | 415 | 32 | 2 | 5.5 | 7.5 | 11 |
| 100-80-125 | 50 | 830 | 5 | 2 | 1.5 | 2.2 | 3 |
| 100-80-160 | 50 | 830 | 8 | 2 | 2.2 | 3 | 4 |
| 100-65-200 | 50 | 830 | 12.5 | 2 | 3 | 4 | 5.5 |
| 100-65-250 | 50 | 830 | 20 | 2 | 5.5 | 7.5 | 11 |
| 100-65-315 | 50 | 830 | 32 | 2 | 11 | 15 | 18.5 |
| 125-80-160 | 80 | 1328 | 8 | 2.3 | 3 | 4 | 5.5 |
| 125-80-200 | 80 | 1328 | 12.5 | 2.3 | 5.5 | 7.5 | 11 |
| 125-80-250 | 80 | 1328 | 20 | 2.3 | 7.5 | 11 | 15 |
| 125-80-315 | 80 | 1328 | 32 | 2.3 | 15 | 18.5 | 30 |
| 125-80-400 | 80 | 1328 | 50 | 2.3 | 22 | 30 | 45 |
Performance data (page 2, n = 2900 r/min)
Density groups are 1.0 / 1.35 / 1.84 g/cm³.
| Model | Flow Q (m³/h) | Flow Q (L/min) | Head H (m) | NPSHr (m) | Motor power at 1.0 g/cm³ (kW) | Motor power at 1.35 g/cm³ (kW) | Motor power at 1.84 g/cm³ (kW) |
|---|---|---|---|---|---|---|---|
| 125-100-200 | 200 | 3320 | 50 | 4.5 | 45 | 75 | 90 |
| 125-100-200 | 250 | 4150 | 50 | 4.5 | 55 | 75 | 110 |
| 125-100-250 | 200 | 3320 | 80 | 4.5 | 75 | 90 | 132 |
| 125-100-250 | 250 | 4150 | 80 | 4.5 | 90 | 110 | 160 |
| 125-100-315 | 200 | 3320 | 125 | 4.5 | 110 | 160 | 200 |
| 125-100-315 | 250 | 4150 | 125 | 4.5 | 132 | 200 | 250 |
| 125-100-400 | - | - | - | 4.5 | - | - | - |
| 125-100-400 | - | - | - | 4.5 | - | - | - |
| 150-125-250 | - | - | - | - | - | - | - |
| 150-125-315 | - | - | - | - | - | - | - |
| 150-125-400 | - | - | - | - | - | - | - |
| 200-150-250 | - | - | - | - | - | - | - |
| 200-150-250 | - | - | - | - | - | - | - |
| 200-150-315 | - | - | - | - | - | - | - |
| 200-150-315 | - | - | - | - | - | - | - |
| 200-150-400 | - | - | - | - | - | - | - |
| 200-150-400 | - | - | - | - | - | - | - |
| 250-200-400 | - | - | - | - | - | - | - |
| 300-250-315 | - | - | - | - | - | - | - |
| 300-250-400 | - | - | - | - | - | - | - |
Performance data (page 2, n = 1450 r/min)
Density groups are 1.0 / 1.35 / 1.84 g/cm³.
| Model | Flow Q (m³/h) | Flow Q (L/min) | Head H (m) | NPSHr (m) | Motor power at 1.0 g/cm³ (kW) | Motor power at 1.35 g/cm³ (kW) | Motor power at 1.84 g/cm³ (kW) |
|---|---|---|---|---|---|---|---|
| 125-100-200 | 100 | 1660 | 12.5 | 2.3 | 7.5 | 7.5 | 11 |
| 125-100-200 | 125 | 2075 | 12.5 | 2.3 | 7.5 | 11 | 15 |
| 125-100-250 | 100 | 1660 | 20 | 2.3 | 11 | 15 | 18.5 |
| 125-100-250 | 125 | 2075 | 20 | 2.3 | 11 | 15 | 22 |
| 125-100-315 | 100 | 1660 | 32 | 2.3 | 15 | 22 | 30 |
| 125-100-315 | 125 | 2075 | 32 | 2.3 | 18.5 | 30 | 37 |
| 125-100-400 | 100 | 1660 | 50 | 2.3 | 30 | 37 | 45 |
| 125-100-400 | 125 | 2075 | 50 | 2.3 | 30 | 45 | 55 |
| 150-125-250 | 200 | 3320 | 20 | 3.0 | 18.5 | 30 | 37 |
| 150-125-315 | 200 | 3320 | 32 | 3.0 | 30 | 37 | 55 |
| 150-125-400 | 200 | 3320 | 50 | 3.0 | 45 | 75 | 90 |
| 200-150-250 | 315 | 5229 | 20 | 4.0 | 30 | 37 | 55 |
| 200-150-250 | 400 | 6640 | 20 | 4.0 | 37 | 45 | 75 |
| 200-150-315 | 315 | 5229 | 32 | 4.0 | 45 | 55 | 75 |
| 200-150-315 | 400 | 6640 | 32 | 4.0 | 55 | 75 | 110 |
| 200-150-400 | 315 | 5229 | 50 | 4.0 | 75 | 90 | 132 |
| 200-150-400 | 400 | 6640 | 50 | 4.0 | 90 | 110 | 160 |
| 250-200-400 | 640 | 10624 | 50 | 4.5 | 132 | 200 | 250 |
| 300-250-315 | 1000 | 16600 | 32 | 5.5 | 132 | 160 | 250 |
| 300-250-400 | 1000 | 16600 | 50 | 5.5 | 200 | 315 | - |
Performance table notes
The following notes apply to both performance-table pages:
- Table values are test values with clean water at 0 °C to 40 °C as the medium.
- Where the flow column has two values, the user selects one according to the required duty.
- Motor power must be selected for the actual medium density.
- The flange pressure rating is 1.6 MPa; a 2.5 MPa flange rating is available on request.
- Inlet and outlet flange hole dimensions can follow ANSI 125FF and 150RF standards on request.
Applications
Suitable industries include chemical, pharmaceutical, petrochemical, paper, metal smelting, food and wastewater treatment.
- Acids, alkalis, salts, organic solvents and chemical reagents within compatible concentration ranges.
- Strongly corrosive and strongly oxidizing media compatible with the selected wetted materials and seal arrangement.
Operating conditions
Main operating conditions:
- Working temperature: −80 °C to 180 °C, depending on the lining material.
- Working-pressure rating: 1.6 MPa; higher working pressure is available on request.
- Related flange rating: 1.6 MPa standard; 2.5 MPa available on request.
Design
- Single-stage, single-suction cantilever construction; performance and external mounting dimensions conform to GB/T 5662, EN 22858 and ISO 2858.
- The IHF series offers shaft-coupled and close-coupled arrangements; the IHF-D is close-coupled, while shaft-coupled models do not carry the D designation.
- Mechanical seal and mechanical-seal cooling/flush arrangements are selected for the duty.
- The impeller is one-piece compression molded and high-temperature fusion bonded, in closed or semi-open form depending on duty and impeller material.
- The impeller design targets high efficiency and low NPSHr. Confirm actual performance for the selected model and duty.
Selection boundaries
Confirm the following during selection and use:
- Temperature range depends on the selected lining material and must be checked for that material. Confirm the applicable pressure/temperature limit against the actual medium, concentration and duty. The nominal pressure rating is 1.6 MPa; higher working pressure is available on request.
- The industries and media above describe the intended application range. Confirm material, seal, flush/cooling, coupling and motor selection for the actual duty.
- Confirm the operating point, density-matched motor power and available speed group with the selection result and supplied technical documentation.
- A dash (“-”) indicates that the value must be confirmed for the selected configuration.
Parameters and definitions are provided for selection. Confirm the final configuration against the selected model and supplied technical documentation.
Product information
| Model designation | IHF-D Fluoroplastic-Lined Chemical Centrifugal Pump |
|---|---|
| Catalog category | Non-metallic Corrosion-resistant Pump |
Related questions
Are non-metal and fluoroplastic pumps the same thing?
Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.
Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.
How is the duty point of a chemical centrifugal pump determined?
Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.
Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.
What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?
Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.
The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.
Which equipment information is needed when requesting an operation manual?
Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.
An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.
What is the minimum data set for pump selection and enquiry?
Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.
The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.
What should be checked first for the foundation and installation space?
First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.
Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.
Which pumps require coupling-alignment checks?
Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.
Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.
Why is one start-up valve arrangement unsuitable for every pump?
Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.
Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.
Which signals should be monitored during normal pump operation?
As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.
The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.
What must be completed before maintenance or disassembly?
Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.
Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.