Products

IHFJ-OH1 Non-metallic Corrosion-resistant Pump

Home > Products > IHFJ-OH1 Non-metallic Corrosion-resistant Pump

IHFJ-OH1 Non-metallic Corrosion-resistant Pump

Product inquiry: 0523-84832479

Product introduction

The IHFJ-OH1 heavy-duty non-metallic shell-type process pump uses pump-casing foot support; the inner/outer casing and split clamp shell carry the structural duty, with materials and seals selected for the application.

Product presentation

IHFJ-OH1 heavy-duty non-metallic shell-type process pump brand visual, showing the company name, slogan, OH1 model lettering, WUXIN PUMP wordmark, foot-supported pump unit, baseplate and blue stage.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These capability highlights summarize the product construction; confirm performance and configuration in the selected model documentation.

MODEL IDENTIFICATION - example IHFJ 50-32-315 A S2 K(VE)

IHFJ50-32-315AS2K(VE)

IHFJ
Non-metallic shell-type process pump series
50 / 32
Suction/discharge opening sizes, in mm
315
Nominal impeller diameter, in mm
A / B / C
Impeller trimming code
S2
Mechanical-seal code
K (VE)
Seal O-ring material code

OH1 pump assembly

Complete oblique IHFJ-OH1 pump unit, showing pump foot support, suction inlet, discharge flange, yellow coupling guard, motor and baseplate.

IHFJ-OH1 non-metallic shell-type process pump: selected details

  • 01 Selected materials: the wetted parts provide good corrosion and oxidation resistance, with materials selected for the medium.
  • 02 Special construction: the outer casing is a precision-cast ductile-iron split clamp shell that carries piping loads and increases overall rigidity.
  • 03 Support arrangement: OH1 uses pump-casing foot support; confirm installation dimensions against the formal assembly drawing.
  • 04 Shaft seal: internally mounted double-face or single-face unbalanced mechanical seals are available, with fluoroplastic-covered sleeves and springs to reduce direct metal contact with the medium.

Performance parameters

IHFJ-OH1 non-metallic shell-type process pump performance parameters
Suction openingDN40~DN400 mm
Flow3.2~2400 m³/h
Head12.5~90 m
Speed1450/2900 r/min
Power1.1~160 kW (above 160 kW: confirm at order)
Operating temperature−80~200 °C
Pressure rating1.6~2.5 MPa

These are series ranges, not a duty point or guarantee for an individual pump. Confirm performance, materials, seals and motor configuration against the medium, duty and formal technical documents.

01 Main applications: broad application range

For acid, alkali and salt solutions and crystallizing media, with solids content no greater than 25 wt%, particle diameter no greater than 3 mm, and kinematic viscosity no greater than 30×10⁻⁶ m²/s (30 cSt, measured at operating temperature).

Confirm concentration, temperature, particle hardness and wetted-material compatibility against the specific duty and selected configuration.

02 Working conditions: customizable to requirements

IHFJ-OH1 non-metallic shell-type process pump working conditions
Operating temperature range−80~200 °C (depending on lining material)
Solids and particle limitsSolids ≤25 wt%; particle diameter ≤3 mm
Kinematic-viscosity limit≤30 cSt (measured at operating temperature)
ConfigurationCustomizable to requirements

Confirm the temperature window, medium conditions and solids limits for the specific medium and selected configuration.

OH1 pump working position

Complete IHFJ-OH1 pump working-condition visual, showing foot support, suction inlet, casing, yellow coupling guard, motor, baseplate and blue background.

03 Design notes: construction and materials

  • The casing uses an inner/outer split construction with an 8~15 mm inner shell; inner-body materials can be selected for the medium and duty, with static vacuum protection. The outer casing is a precision-cast ductile-iron split clamp shell.
  • Closed or semi-open impellers contain a reinforced high-strength metal insert. The large-volume cover is intended for solids-bearing or crystallizing media and can reduce the effect of accumulated particles or crystals on the mechanical seal.
  • Shaft-seal options include internally mounted double-face or single-face unbalanced mechanical seals. WXS1 is the single-face model and WXS2 the double-face model; SiC/SSiC face pairs and FKM, FFKM or EPDM O-rings are available.
  • Wetted material options include UHMWPE, FRPP, PTFE/FEP/CF/GF, ETFE, PEEK and PVDF. Confirm the material, temperature and medium compatibility for the ordered configuration and formal technical documents.

Product information

Model designationIHFJ-OH1 Non-metallic Corrosion-resistant Pump
Catalog categoryNon-metallic Corrosion-resistant Pump

Related questions

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

How is the duty point of a chemical centrifugal pump determined?

Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.

Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.