Products

FSB-L Fluoroplastic Alloy Corrosion-Resistant Centrifugal Pump

Home > Products > FSB-L Fluoroplastic Alloy Corrosion-Resistant Centrifugal Pump

FSB-L Fluoroplastic Alloy Corrosion-Resistant Centrifugal Pump

Product inquiry: 0523-84832479

Product introduction

The FSB-L fluoroplastic-alloy corrosion-resistant centrifugal pump uses a shaft-coupled arrangement. Confirm the wetted materials and seal configuration against the actual medium.

Product presentation

FSB-L fluoroplastic-alloy corrosion-resistant centrifugal pump

FSB-L fluoroplastic-alloy corrosion-resistant centrifugal pump, showing the white pump cover, green casing, yellow coupling guard, motor and black base.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These performance advantages depend on the medium, duty and selected model.

MODEL IDENTIFICATION - example 80 F SB -30 L, nomenclature only

80FSB-30L

80
Suction opening, in mm
F
Pump material is fluoroplastic alloy
SB
Single-stage, single-suction cantilever centrifugal pump
-30
Rated head, in m
L
Shaft-coupled code; no suffix denotes direct-coupled

FSB-L shaft-coupled pump assembly

FSB-L fluoroplastic-alloy corrosion-resistant shaft-coupled pump, showing the white suction cover, green casing, yellow coupling guard, motor and black base.

FSB-L fluoroplastic-alloy corrosion-resistant centrifugal pump: selected details / independently developed, distinctive construction

  • 01 Selected material: good corrosion resistance and oxidation resistance.
  • 02 Special construction: an external single-end balanced mechanical seal that adjusts automatically and requires no cooling water under normal conditions.
  • 03 Multiple fluoroplastic advantages: the material is resistant to aging and does not produce toxic decomposition products.

Performance parameters

FSB-L fluoroplastic-alloy corrosion-resistant centrifugal pump series parameters
Suction openingDN25~DN125 mm
Operating temperature−80~150 °C
Flow1.5~200 m³/h
Pressure rating1.6 MPa
Head5~50 m
Speed1450 / 2900 r/min
Power0.75~75 kW

These are FSB-L series parameter ranges, not guarantees for an individual model. Confirm the medium, flow, head, temperature, materials, seal and motor configuration during selection.

01 Main applications: broad application range

Fluoroplastic alloy is suitable for corrosive chemical media that contain no easily crystallizing components.

Polyvinylidene fluoride (PVDF) and engineering plastics are suitable for neutral or weakly corrosive acid, alkali and salt media, and wastewater containing neither strongly oxidizing media nor organic solvents.

Consult the material chemical-resistance data for medium selection. Confirm compatibility, temperature, concentration and operating conditions against the selected material and formal technical documentation.

02 Working conditions: customizable to requirements

FSB-L fluoroplastic-alloy corrosion-resistant centrifugal pump working conditions
Operating temperature range−80~150 °C (depending on liner material)
ConfigurationCustomizable to requirements

The operating-temperature range depends on the lining material. Confirm suitability against the medium, concentration and selected configuration.

FSB-L shaft-coupled pump working position

FSB-L shaft-coupled pump on a light-colored floor, showing the white suction inlet, green casing, yellow coupling guard, motor and black base.

03 Design notes: construction and materials

  • The wetted parts use a fluoroplastic alloy made by combining multiple fluoroplastics and high-temperature sintered compression molding. It combines the corrosion and oxidation resistance of its fluoroplastic components with relatively high mechanical strength and stable performance within the permitted operating range. Where the medium and material are compatible and the conditions fall within the selection range, it can be an alternative to pumps made from titanium, nickel and other such metals, and nickel-base alloys.
  • The seal is an external single-end balanced mechanical seal with automatic pressure adjustment; under normal conditions it does not require an external cooling-water connection. Seal models WB2 and 169 are available, with the structure selected for the duty. Stationary-ring options are high-purity alumina ceramic, silicon carbide, nickel-base alloy and cobalt-base alloy. Rotating-ring options are filled polytetrafluoroethylene, silicon carbide, nickel-base alloy and cobalt-base alloy.
  • Product features: broad application range; good corrosion resistance; relatively high operating efficiency that helps reduce energy consumption; compact construction with relatively low operating and maintenance costs; convenient maintenance.

Product information

Model designationFSB-L Fluoroplastic Alloy Corrosion-Resistant Centrifugal Pump
Catalog categoryNon-metallic Corrosion-resistant Pump

Related questions

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

How is the duty point of a chemical centrifugal pump determined?

Build the system curve from static head, piping loss, equipment differential pressure and pressure conditions at target flow, then find its intersection with the exact pump curve.

Without the exact curve, material list and seal configuration, only the review method can be stated; final size, life or operating outcome cannot be confirmed.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.