Products

HYP-K Fluoroplastic Alloy Submerged Pump

Home > Products > HYP-K Fluoroplastic Alloy Submerged Pump

HYP-K Fluoroplastic Alloy Submerged Pump

Product inquiry: 0523-84832479

Product introduction

The HYP-K fluoroplastic-alloy submerged pump uses a vertical submerged arrangement. Its wetted parts are fluoroplastic or engineering plastic, and the HYP-K support column uses an internal and external plastic-covered skeleton. Confirm the material, submerged depth and operating conditions for the selected model.

Product presentation

HYP-K fluoroplastic-alloy submerged pump

HYP-K fluoroplastic-alloy submerged pump, showing the top motor, mounting plate, long submerged support column, side pipe and immersed pump head.
  • High-temperature resistance
  • High mechanical strength
  • Long service life
  • Broad application range

These product capabilities are an overview; confirm performance for the selected configuration.

Structure and equipment visual

HYP-K vertical submerged pump showing the green motor, coupling, black mounting plate, long support column, side pipe and immersed pump head.

Performance parameters

HYP-K series parameter range
Suction openingDN25~DN150 mm
Operating temperature−40~120 °C
Flow3.6~200 m³/h
Pressure rating1.6 MPa
Head20~50 m
Submerged depth0.5~2 m (above 2 m uses a reverse-suction pipe)
Speed1450~2900 r/min
Power1.5~55 kW

These values describe the series range. Confirm actual performance against the selected model, materials and operating conditions.

Equipment details

  • 01 Selected material: very strong corrosion resistance and oxidation resistance.
  • 02 Special construction: all medium-contacting wetted parts are fluoroplastic or engineering plastic.
  • 03 Vertical construction: a single-suction, single-stage vertical arrangement improves coaxiality and substantially extends service life.

Main applications

For lifting and transferring strongly corrosive low-level liquids that contain some particulate impurities from tanks, vessels, pits and sumps.

Confirm medium compatibility, particle conditions and installation method for the actual duty and selected model.

Working conditions

HYP-K working conditions
Operating temperature range−40~120 °C (depending on lining material)
ConfigurationCustomizable to requirements

The temperature range depends on the lining material. Confirm the permitted value for the selected model and duty.

Two HYP-K vertical submerged pumps showing the green motors, couplings, mounting plates, long support columns, side pipes and bottom suction ends.

Structural design

  • All medium-contacting wetted parts are fluoroplastic or engineering plastic; the pump has a single-suction, single-stage vertical construction.
  • The support column has external reinforcing ribs to increase the rigidity of the non-metallic column, improve coaxiality and extend service life.
  • The HYP-K is a high-flow, higher-head submerged pump whose support column uses an internal and external plastic-covered skeleton, intended to achieve rigidity comparable to a metal column and resist most chemical media; confirm actual medium compatibility.
  • The equipment has a running dynamic seal and a static parking seal and is designed for environmentally safe operation; confirm the configuration for the selected model.

Selection guidance

The HYP-K is intended for lifting and transferring low-level liquids from tanks, vessels, pits and sumps.

For selection, provide the medium, concentration, temperature, viscosity, solids content and required submerged depth, then confirm the materials and configuration against the installation conditions.

Confirm performance, temperature and seal configuration against the selected model, materials and formal technical documentation before ordering.

Product information

Model designationHYP-K Fluoroplastic Alloy Submerged Pump
Catalog categoryNon-metallic Corrosion-resistant Pump

Related questions

Are non-metal and fluoroplastic pumps the same thing?

Not exactly. Non-metal is a wider design/material family, while fluoroplastic is one material clue. Solid, lined, clamped, magnetic-drive and sealed designs must still be distinguished.

Do not make unconditional material claims across media or concentration ranges, and do not extend one material/model limit to the whole family.

Why are vessel dimensions required for submerged-pump selection?

Vessel depth, opening, mounting plane, obstructions and suction location determine immersion, mounting plate, supports and maintenance space; one level value is insufficient.

Do not infer site performance from patents, collaboration statements or family names; depth and interfaces remain unconfirmed until the installation drawing is reviewed.

What should be confirmed before selecting or working on pumps for corrosive, flammable, explosive, toxic or volatile media?

Obtain the SDS and complete duty first, identify corrosion, toxicity, fire/explosion, volatility, reactivity and exposure routes, then review wetted materials, containment/disposal, hazardous-area equipment, monitoring, emergency and personnel controls separately. A pump-family name does not establish risk control.

The project owner or responsible team must confirm site safety through professional risk assessment, relief and disposal design, hazardous-area equipment compliance, rescue arrangements and medical and occupational-health requirements.

Which equipment information is needed when requesting an operation manual?

Provide the complete model and model suffix, a clear nameplate photo, order or serial information, current configuration and required language. If the unit has been modified, describe the change so the manual is not matched from the series name alone.

An unregistered file requires public-release approval before it is shared. A filename, product photo or similar model cannot replace complete equipment-identity and revision checks.

What is the minimum data set for pump selection and enquiry?

Provide medium composition, concentration, density, viscosity and temperature; normal/minimum/maximum flow and head; suction, discharge and system pressure; available NPSH; solids or particle data; installation arrangement and space; power supply; and environmental conditions including indoor/outdoor location, temperature/humidity, altitude and hazardous-area classification.

The selection-input checklist gathers process and equipment information. Process design, piping calculations, final material configuration, hazardous-area suitability review and final quotation require the complete project package, and every missing field must remain explicitly open.

What should be checked first for the foundation and installation space?

First confirm foundation dimensions, anchor locations, load capacity and level from the order drawing. Then isolate the unit from adjacent-machine vibration and retain access for lifting, motor removal, inspection and disassembly.

Civil calculations, piping stress analysis, lifting plans, electrical codes, site safety approval and order drawings must be confirmed by the responsible disciplines and project documents. Dimensions from a similar model must not replace order drawings.

Which pumps require coupling-alignment checks?

Use the sectional drawing to identify direct drive, a separate coupling or a vertical shaft arrangement. Apply the model-specific alignment procedure only to the relevant connection; one tolerance does not fit every pump.

Alignment tolerance, jog duration and electrical steps must be determined for the exact model and site procedure. Perform a rotation check only after energy control, guarding and site authorization are complete.

Why is one start-up valve arrangement unsuitable for every pump?

Conventional centrifugal, self-priming and submerged pumps, as well as magnetic-drive pumps with different circulation paths, have different suction states, venting paths and permissible flow ranges. Valve positions must match the exact model and system control logic.

Remote start-up must follow the site authorization procedure. Valve positions, vent cycles and closed-valve duration must be determined from the matching manual revision and site procedure, and must not be transferred across models.

Which signals should be monitored during normal pump operation?

As configured, record flow, suction/discharge pressure, current, speed or frequency, vibration, sound, bearing or critical-point temperature, plus level, flushing, cooling and alarm states.

The site team must confirm continued operation through interlock settings, instrument calibration, root-cause analysis and maintenance permits. Do not restart until the cause and safety conditions are confirmed.

What must be completed before maintenance or disassembly?

Follow site procedure for shutdown, energy isolation, valve locking, depressurization, cooling, draining, flushing or decontamination, and verify that unintended start is prevented. Hazardous media also require the applicable work permit and personal protection.

Do not substitute drawings, part dimensions or materials from a similar model. A single symptom cannot establish root cause or a replacement part without site inspection.